Gasdetectorsusa.com:gas Leak And Flame Detectors, Analyzers, Alarm Devices And Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
ANALOG:    218 Items found.
(2516)

FHF  11230020

FHF FernTel 3 Weatherproof Analogue Desk/Wall Telephone for indoor and outdoor use. Polycarbonat Shock-resistant housing. Display key at displayversion. IP65 (IEC60529).

Configure

$1,232.22 
(2518)

FHF  11234021

FHF FernTel 3 ZB Weatherproof Analogue Hotline Telephone with call tone unit for indoor and outdoor use (Without keypad). Polycarbonat Shock-resistant housing. IP65 (IEC60529).

Configure

$1,202.47 
(2519)

FHF  11240020

FHF FernTel 3 Explosion Proof (Ex) Analogue Desk/Wall Telephone for use in areas with explosive atmospheres. Zone 2, 22. IP65.

Configure

$1,636.55 
(2520)

FHF  11245021

FHF FernTel 3 ZB Explosion Proof (Ex) Analogue Desk/Wall Telephone (Without keypad) for use in areas with explosive atmospheres. Zone 2, 22. IP65. With armored cord.

Configure

$1,619.05 
(2525)

FHF  11264432

FHF FernTel W Weatherproof Built-in Analog phone for indoor and outdoor use. With or without keypad (ZB). IP65

Configure

$1,249.73 
(2530)

FHF  11264501

FHF InduTel Weatherproof Analogue Telephone for indoor and outdoor use. Syntetic Housing with protection door. Connector for secondary call bell. IP66 (IEC60529). UL Certification Available.

Configure

$1,020.44 
(2531)

FHF  11264502

FHF InduTel ZB Weatherproof Analogue Telephone for indoor and outdoor use (Without keypad). Syntetic Housing with protection door. Connector for secondary call bell. IP66 (IEC60529).

Configure

$994.19 
(2532)

FHF  11264506

FHF InduTel LED Weatherproof Analogue Telephone for indoor and outdoor use (With visual indication). Syntetic Housing with protection door. Connector for secondary call bell. IP66 (IEC60529). UL Certification Available.

Configure

$1,142.96 
(2930)

SPECTREX  40/40UFL-111AF

SPECTREX SharpEye 40/40UFL UV-IR High-Speed Optical Flame Detector for hydrocarbon-based fuel and gas fires. High-Speed Response (20 msec) to flash fire and High Reliability and immunity to false alarm, design based on military specifications. 2 Relays (Alarm and Fault), 0-20mA stepped and analogue output for fast detection. Compatible with RS-485 Modbus. Automatic and Manual Built-In-Test (BIT) feature included. Ex approved for Zone 1, ATEX, IECEx, FM and CSA Class I Div 1. EN54-10 (VdS Germany) approved. 5 year warranty and is SIL2 (TUV) approved to IEC 61508 *** Phased Out replaced by 40/40D-LB ***



 
(6845)

TYCO  4098-9714

Tyco Simplex 4098-9714 TrueAlarm Analog SSD Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

(6852)

TYCO  4098-9733

Tyco Simplex 4098-9733 TrueAlarm Analog Heat Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

Configure

$25.86 
(7073)

TYCO  4098-9757

Tyco Simplex 4098-9757 QuickConnect2 TrueAlarm Analog Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet communications. Ceiling or wall mounting. NEMA 1. UL Approved.

Configure

$61.78 
(7069)

TYCO  4098-9792

Tyco Simplex 4098-9792 sensor base for TrueAlarm Analog Heat Sensors

(2912)

INTEC  AT-2064-A-000-0

Intec Controls PolyGard AT-2000 V3 Analog Gas Transmitter for Refrigerants (HCFC and HFC) 0-500 / 0-1000 / 0-2000 ppm (infrared). 2 relay outputs, 1 4-20mA & 2-10V analog output. Wall mounted. NEMA 4X Enclosure. UL Listed and CSA Certified. Factory configured for either R123, R125, R410a, R22, R134a, R404a or R407a

Configure

$1,251.00 
(5146)

FRESENIUS  BIOBASIC-BG

Fresenius BioBasic BioGas, Landfill or Waste Water Analyzer for measurement of Methane (CH4) and Carbon Dioxide (CO2) 0-100% vol. via NDIR, Hydrogen Sulfide (H2S) 0-2.000 ppm (10,000 ppm overload) and Oxygen (O2) with electrochemical sensors (All Optional). 4 digital 24VDC/DC inputs, 6 digital outputs and 4 x 4-20mA analog outputs per sampling point, up to 5 sampling points . Includes sequencer, 4 LPM internal sampling pump, sintered metal filter, pressure regulator 0.7-1.1 bar, fresh air purge, touch panel, RS232, condensate trap, pump, level monitoring, automatic drain and flame barrier. ATEX certification included, UL optional.

Configure

$6,842.88 
(1641)

GDS  C1/SM/0000/000000/00000

C1 Multi-Point Alarm gas detector Controller with 8 or 16 channel alarm & display controller for monitoring applications. It can be configured for GAS MAX wireless gas monitors. Standard 5A SPDT common relays and up to 48 discrete relays. 1 or 2 optional 8-channel 4-20mA analog outputs. Operates on 10-30VDC or 110/220V 50/60Hz AC. Available certifications: CSA and UL. Includes Modbus RTU slave RS-485 port for sending data to PC, PLC or DCS.



 
(619)

GDS  C64/PM-00-00-00/0-00-0/00/0-0-0-0/0-0-0

GDS C64 Protector Controller in Panel Mount (includes hardware) with up to 64 channels of analog, bridge, digital, wireless or MODBUS TCP. Large color LCD Display shows values, trends, bargraph and more. Pushbutton ZERO and SPAN calibration for direct sensors. Five standard 5A SPDT relays for A1, A2, A3, Horn and Fault. Certified for use in Class 1 Div 2 hazardous areas. Can be used for any 4-20 mA process variables.



 
(6900)

INTEC  DGC6-A-00-0000US

Intec Controls PolyGard 2 DGC6 Multi-Point Digital Gas Detection and Control System for up to 96 sensors (toxic, combustible and refrigerant gases). Single or Multi-zone applications. Wall Mounted. 4 x 4 to 20mA inputs, 4 alarm relays, 4 digital inputs, up to 16 analog outputs (binary, 4-20 mA) and up to 32 alarm relays, and/or optional BACnet-IP and/or Modbus-RTU port. LCD Display. 120 VAC. NEMA 4X enclosure. IP65. UL Listed. *** Phased Out ***



 
(6823)

MACURCO  DVP-1200

Macurco DVP-1200 control panel for up to 192 addressable detectors. Includes 4 Relays (Up to 12), 3 4-20mA analog outputs, 4 24VDC drivers, 3 RS-485 channels and BACnet IP server output. NEMA4X enclosure. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. ETL Listed to UL 2017

Configure

$2,764.23 
(4471)

FELIX  F-900

Felix F-900 Portable Ethylene (C2H4) Produce Gas Analyzer 0-10ppm/0-200ppm auto selection of Electrochemical Sensor and PolarCept filter technology, Ethylene lower detection limit 25ppb. Enables trace measurement in any location. Optional CO2 and O2 measurement with extra sensors. Rechargeable battery and LCD Display. Continuous Monitoring. 4-20 mA Analog, gas valve and alarm Digital Outputs.

Configure

$9,727.05 