Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

TYCO  4098-9733

TYCO 4098-9733
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE

Tyco Simplex 4098-9733 TrueAlarm Analog Heat Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

Part# with Options:        4098-9733
Price with Options:        Please Email us your request for quote   

Options:    

Version
(1) Version for Simplex Heat Sensor
Bases
(2) Bases for Simplex Sensors

  Availability 4 Weeks  ]

Features TrueAlarm analog sensing provides the following features
  • Digital transmission of analog sensor values using IDNet or MAPNET II two-wire communications
For use with the following Simplex products
  • 4007ES, 4010, 4010ES, 4100ES, and 4100U Series control units and 4008 Series control units with reduced feature set (refer to data sheet S4008-0001 for details)
  • 4020, 4100, and 4120 Series control units, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation
Heat sensors have these features
  • Three fixed temperature sensing thresholds: 135F, 155F and 190F
  • Rate-of-rise temperature sensing
  • Utility temperature sensing
  • Listed to UL 521 and ULC-S530
General features
  • Ceiling or wall mounting
  • Listed to UL 268 7th Edition and ULC-S529
  • NEMA 1 rated. See TrueAlarm analog sensing product selection chart for more information.
  • Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted
  • Designed for EMI compatibility
  • Magnetic testing
  • Different bases support a supervised or unsupervised output relay, or a remote LED alarm indicator
Additional base reference
  • For isolator bases, refer to data sheet S4098-0025
  • For sounder bases, refer to data sheet S4098-0028
  • For photo/heat sensors, refer to data sheet S4098-0024 , single address and S4098-0033 , dual address
Digital communication of analog sensing

TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. The control unit analyses the data, determines an average value and stores it. Comparing the sensor's present value against its average value and time, determines an alarm or other abnormal condition.

Intelligent data evaluation

Monitoring each sensor's average value provides a continuously shifting reference point. A software filtering process compensates for environmental factors, such as dust and dirt, and component aging, to provide an accurate reference for evaluating new activity. This filtering reduces the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down.

Control unit selection

The control unit stores peak activity for each sensor to assist in evaluating specific locations. The host control unit determines the alarm set point for each TrueAlarm sensor, selectable as more or less sensitive as the individual application requires.

Timed/multi-stage selection

You can program the sensor alarm set points for timed automatic sensitivity selection, such as more sensitive at night, less sensitive during day. You can program the control unit to provide multi-stage operation for each sensor.

Sensor alarm and trouble LED indication

Each sensor base's LED pulses to indicate communications with the unit. If the control unit determines a sensor is in alarm, is dirty, or has some other type of trouble, the details are annunciated at the control unit and the sensor's base LED will turn on steadily. During a system alarm, the control unit will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors.

TrueAlarm sensors
  • Sealed against rear air flow entry
  • Interchangeable mounting
  • EMI/RFI shielded electronics
Smoke sensors
  • Photoelectric technology sensing
  • 360 smoke entry for optimum response
  • Built-in insect screens
4098-9733 and 4098-9734 heat sensors

TrueAlarm heat sensors are self-restoring and provide rate- compensated, fixed temperature sensing, you can select with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control unit.

You can select rate-of-rise temperature detection at the control unit for either 15F or 20F, (8.3C or 11.1C) for each minute. Fixed temperature sensing is independent of rate-of-rise sensing and you can program it to operate at 135F or 155F (57.2C or 68C). The 4098-9734 sensor provides an additional 190F (88C) set point.

In a slowly developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting.

You can program TrueAlarm heat sensors as a utility device to monitor for temperature extremes in the range of 32F to 155F (0C to 68C). This feature can provide freeze warnings, or alert you to HVAC system problems. Refer to panel specifications for availability.

Specifications
Communications and sensor supervisory powerIDNet or MAPNET II communications, auto-selected, one address for each base
Communications connectionsScrew terminals for in/out wiring, 18 to 14 AWG, 0.82 mm to 2.08 mm
Remote LED alarm indicator current1 mA typical, no impact to alarm current
Remote LED alarm indicator and relay connectionsColor coded wire leads, 18 AWG, 0.82 mm
UL listed operating temperature range32F to 100F, 0C to 38C
Operating temperature range32F to 122F, 0C to 50C
Storage temperature range0F to 140F, -18C to 60C
Humidity rangeHumidity range
4098-9714 smoke sensor air velocity rating0 to 4000 ft/min, 0 to 1220 m/min
Housing colorFrost white or black
 


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> INTELLIGENT :    13 Items found.
5601P
(4021)

NOTIFIER  5601P

Notifier System Sensor Mechanical Heat Detector

4098-9714
(6845)

TYCO  4098-9714

Tyco Simplex 4098-9714 TrueAlarm Analog SSD Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

4098-9612
(6854)

TYCO  4098-9612

Simplex 4098-9612 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. 15 to 32 VDC. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

FST-951
(3228)

NOTIFIER  FST-951

Notifier FST-951 Series Intelligent Addressable Thermal (Heat) Detector with FlashScan and CLIP protocol systems. Two-wire SLC connection and 360 viewing angle. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FST-851 ***

4098-9754
(6847)

TYCO  4098-9754

Tyco Simplex 4098-9754 TrueAlarm Multi-Point Analog Photoelectric and Thermistor Sensor for Early Fire Detection (smoke and thermal activity). IDNet communication. Ceiling or wall mounting. UL, ULC, CSFM and FM Approved.

2W_-B
(6927)

NOTIFIER  2W-B

NOTIFIER by Honeywell i3 Series Photoelectric and Thermal Smoke Detector. Wide angle and dual color LED indicator. Mounting base included. UL, FM, and CSFM Approved.

FSP-951
(2038)

NOTIFIER  FSP-951

NOTIFIER by Honeywell FSP-951 Series Intelligent Plug-in Photoelectric Smoke Detector (0.5% to 4% per foot obscuration) with FlashScan and CLIP communication protocol systems. Addressable-analog communication. Optional relay, isolator and sounder bases. UL, ULC, FM and CSFM Approvals. *** Replaces FSP-851 ***

4098-9401
(6846)

TYCO  4098-9401

Tyco Simplex 4098-9401 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

FPTI-951
(6825)

NOTIFIER  FPTI-951

NOTIFIER by Honeywell FPTI-951 Multi-Criteria Photo/Thermal/Infrared Detector with FlashScan and CLIP protocol systems. Dual LEDs for 360 visibility. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FAPT-851 ***

DNR
(6866)

NOTIFIER  DNR

Notifier DNR intelligent Photoelectric Duct Smoke Detector for mounting to round or rectangular ducts. Non-Relay. Optional NEMA-4 watertight enclosure. Air velocity rating from 100 ft/min to 4,000 ft/min. Remote testing capability. UL, ULC, CSFM and FM approved.

FCO-951
(3502)

NOTIFIER  FCO-951

Notifier IntelliQuad PLUS FCO-951 Advanced Multi-Criteria Fire/CO Detector with four unique sensing elements: Carbon Monoxide (CO) electrochemical sensor, Infrared (IR) sensing measure, Photo-electric smoke detection and Thermal detection. UL listed. *** replaces FSC-851 ***



 
FSV-951R
(3229)

NOTIFIER  FSV-951R

Notifier FSV-951R Series Very Intelligent Plug-in Early Warning (VIEW) Laser Smoke Detector. 0.03% to 1.00% (CLIP) or 0.02% to 2.00% (other) sensivity. With FlashScan and CLIP protocol systems. Advanced laser light source and 360 viewing angle. Optional relay, isolator and sounder bases. UL and MEA listed. FM, CSFM, BSMI and CCCF Approved. (replaces FSL-751)

FS-OSI-RI
(6933)

NOTIFIER  FS-OSI-RI

Notifier FS-OSI-RI Intelligent Addressable Single-ended Reflective Imaging Beam Smoke Detector suited for large open areas with high ceilings. 24 VDC. 12 field of view. Status LED indicators. UL and FM approved.