Fresenius BioBasic BioGas, Landfill or Waste Water Analyzer for measurement of Methane (CH4) and Carbon Dioxide (CO2) 0-100% vol. via NDIR, Hydrogen Sulfide (H2S) 0-2.000 ppm (10,000 ppm overload) and Oxygen (O2) with electrochemical sensors (All Optional). 4 digital 24VDC/DC inputs, 6 digital outputs and 4 x 4-20mA analog outputs per sampling point, up to 5 sampling points . Includes sequencer, 4 LPM internal sampling pump, sintered metal filter, pressure regulator 0.7-1.1 bar, fresh air purge, touch panel, RS232, condensate trap, pump, level monitoring, automatic drain and flame barrier. ATEX certification included, UL optional.

Part# with Options:        BIOBASIC-BG
Price with Options:        6,842.88

Options:    

Calibration
(1) Calibration for Fresenius Biobasic
O2 Sensor
(2) O2 Sensor For Fresenius BioBasic
CO2 Sensor
(3) CO2 Sensor For Fresenius BioBasic
H2 Sensor
(4) H2 Sensor For Fresenius BioBasic
CH4 Sensor
(5) CH4 Sensor For Fresenius BioBasic
H2S Sensor
(6) H2S Sensor For Fresenius BioBasic
Interface
(7) Interface/Output for Fresenius
Certification
(8) Agency Approval for Fresenius
Power Adaptor
(9) Power Adaptor for Fresenius
Sampling Point
(10) Sampling point for Fresenius BioBasic with Analog Outputs
Includes filter, ball valve 1/2", connection kit for 1/2" and 1"(alternate).
Fresenius Sampling Point

  Availability 4 Weeks  ]


The BioBasic is a gas analyzer that was developed for the fast and reliable online-gas-measurement in biogas plants .

The BioBasic analyzes the quality of the process gas and thus allows the operator an efficient process control to maximize the methane yield. In addition, the BioBasic analyzes the H2S content in the process gas. This metric is used to initiate appropriate measures for the protection of gas engines and catalysts. It may also be configurated to your individual needs.

Advantages
  • measurements of Methane (CH4) and Carbon Dioxide (CO2) 0-100% vol. via NDIR, Hydrogen Sulfide (H2S) 0-2.000 ppm (10,000 ppm overload) and Oxygen (O2)
  • easy control via touch panel
  • error description in plain text
  • flexible data transfer
  • up to 5 measuring points
  • long term calibration stability
  • high efficiency at low service costs
Fields of application
  • biogas plants
  • wastewater treatment
  • landfill sites

technical data
model:BioBasic
display:in Vol.-%, ppm via touch panel 128 x 64 pixel, black/white
operation:touch panel, resistive
measurement output:after 20 seconds
measurement interval:15 - 999 min.
measurement precision:ca. 3 % from measured value as well as < 1 % from upper range value / long-term drift % < 3 % / year (IR)
electronic inputs:4 digital inputs 24 V AC / DC
electronic outputs:2 digital (ready / fault), 4 digital and 4 analog (free programmable & galvanically isolated)
interfaces:standard RS 232
optional: Profibus DP, Ethernet Modbus TCP, Ethernet IP, Profinet
gas flow:ca. 4.0 l/min / 140.78 oz/min
pressure compatibility:compensated, standard 0.7 - 1.1 bar / 10.15 - 15.95 psi
supply voltage:230 V AC / 50 Hz, 0.9 A / 207 VA
climatic requirements:ambient temp. 5° - 45°C / 41° - 113°F / relative humidity ~ 90 %, dew free
case:wall cabinet IP 54: 400 x 400 x 220 mm / 15.75 x 15.75 x 8.66 inch
tube connections:8 mm off-site / 6 mm in-site (0.35” off-site/ 0.27” in-site)
gas processing:condensate trap incl. level guard, automatic drain, explosion proof (ATEX, UL and CSA)
measuring inputs:1 (standard)
measuring components:CH4(IR) and H2S (EC) (basic unit)
range:CH4 = 0-1.000.000 ppm
H2S = 0-2.000 ppm
CO2 = 0-650.000 / -1.000.000 ppm
O2 = 0-250.000 ppm
cuvette:heated to 60°C / 140°F
Warranty:12 Months
basic system:to measure CH4 and H2S, consisting of:
wall cabinet incl. touch panel interface and controlled housing fan, one measuring point included, flame barriers, fresh air purge, internal CH 4 monitoring, internal gas pump, condensate trap incl. level guard, automatic condensate drain, machine interface, RS 232, analog output 4-20 mA
options:upgrades and accessories:
measurement enhancement up to CO 2 , H 2 and/or O2 , up to a total of 5 measuring points, different types of sampling points
Export Info
Made inGermany
Harmonized Tariff Code (HTC)90279050
 


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
CYL-90403365
(6610)

PORTAGAS  CYL-90403365

Calibration Gas Methane/Biomethane/Biogas (CH4) 50% VOLUME Balance Nitrogen, 100 Liter FAL (Flammable Aluminum Cylinder) C-10 Inlet (Made by Portagas)

Configure

$103.27 
> CH4 H2S CO2 O2 :    2 Items found.
951010
(6766)

MRU  951010

MRU SWG 100 BIO COMPACT Semi-Continuous Biogas Analyzer for measurement of Methane (CH4) 0-100 %, Carbon Dioxide (CO2) 0-100 %, Oxygen (O2) 0-25 % and Hydrogen Sulfide (H2S) 0-2000ppm or 0-4000ppm, Hydrogen (H2) 0-1000ppm. Up to 3 monitoring sites. Suitable for harsh industrial environments. RS485 Modbus RTU. Optional 4x4-20 mA, 2 alarm relays and Profibus/EthernetIP Networking. IP54. Includes sample pump, condensate trap with draining pump, auto zero solenoid valve, TFT display and universal power supply.

Configure

$6,595.00 
GA220-BG
(6141)

FRESENIUS  GA220-BG

Fresenius GA220 BioGas, Landfill or Waste Water Analyzer for measurement of up tp 3 IR and 3 EC gases with NDIR and electrochemical technology, 19" rack mount. Includes 3 Hydrogen Sulfide (H2S) sensors 0-2000 ppm (used in sequence to triple sensor life), sequencer, 4 LPM internal sampling pump, sintered metal filter, pressure regulator 0.7-1.1 bar, touch panel display, 4 digital inputs, 6 digital outputs (relay) and RS232 interface. CE Approval.

Configure

$15,068.16