Notifier Fsi-851 | Intelligent | Smoke (ionization) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   FSI-851

SKU# (3512)
NOTIFIER FSI-851
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier FSI-851 Intelligent Plug-In Ionization Smoke Detector with FlashScan. 0.5% to 2.5% sensivity. Compatible with ONYX series and CLIP series intelligent Fire Alarm Control Panels. Dual LED provides 360° viewing angle. Optional relay, isolator or sounder bases. UL and MEA listed. FM, CSFM and BSMI *** Phased Out *** Comparable To FSP-851

RELAYS   UL   FM

Inquiry

The FSI-851(A) intelligent plug-in ion detectors with integral communication has features that surpass conventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector locations for selective maintenance when chamber contamination reaches an unacceptable level.

The FSI-851(A) ionization detector incorporates a unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. FSI-851(A) detectors are compatible with ONYX series and CLIP series intelligent Fire Alarm Control Panels (FACPs).

FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by NOTIFIER that greatly improves the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel’s CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other protocols.

FEATURES

  • Sleek, low-profile design.
  • Addressable-analog communication.
  • Stable communication technique with noise immunity.
  • Low standby current.
  • Two-wire SLC connection.
  • Compatible with FlashScan® and CLIP systems Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems).
  • Optional remote, single-gang LED accessory, RA100Z(A).
  • Dual LED design provides 360° viewing angle.
  • Visible bicolor LEDs blink green every time the detector is addressed, and illuminate steady red on alarm.
  • Remote test feature from the panel.
  • Walk test with address display (an address of 121 will blink the detector LED: 12-(pause)-1) (FlashScan® systems only).
  • Built-in functional test switch activated by external magnet.
  • Built-in tamper-resistant feature.
  • Sealed against back pressure.
  • Constructed of off-white plastic, designed to commercial standards, and offers an attractive appearance.
  • 94-5V plastic flammability rating.
  • SEMS screws for wiring of the separate base.
  • Optional relay, isolator, or sounder bases.
  • Listed to UL 268.
Installation

FSI-851(A) plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors without using a ladder.

Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054.

NOTE: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet I56-1380 for device limitations between isolator modules and isolator bases.

Agency Listings and Approvals

These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL Listed: S1115.
  • ULC Listed: S1115 (FSI-851A).
  • CSFM: 7271-0028:201.
  • MEA: 321-02-E.
  • Maryland State Fire Marshal: Permit #2140.
  • BSMI: CI313066760014.
  • U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B210LP(A)).
  • Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS-320C, excluding B210LP(A)).
  • FM Approved.
ACCESSORIES

F110: Retrofit flange to convert B210LP(A) to match the B710LP(A) profile, or to convert older high-profile bases to low-profile.
F110BP: Bulk pack of F110; package contains 15.
F210: Replacement flange for B210LP(A) base.
RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B210LP(A) bases only.
SMB600: Surface mounting kit.
M02-04-00: Test magnet.
M02-09-00: Test magnet with telescoping handle.
XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions.
XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections.
T55-127-010: Detector removal tool without pole.
BCK-200B: Black detector covers; package contains 10.
WCK-200B: White detector covers; package contains 10.

FSI-851 SPECIFICATIONS
Sensitivity: 0.5% to 2.5% per foot obscuration
Size: 2.0" (51 mm) high; base determines diameter.
– B210LP(A): 6.1" (15.5 cm) diameter.
– B501(A): 4.1" (10.4 cm) diameter.
– B200S(A): 6.875" (17.46 cm) diameter.
– B200SR(A): 6.875" (17.46 cm) diameter.
– B224RB(A): 6.2" (15.748 cm) diameter.
Shipping Weight: 5.4 oz. (153 g).
Operating temperature: 0° to 49°C (32° to 120°F).
UL/ULC-Listed Velocity Range: ION: 0 – 1200 ft./min. (365.76 m/min.).
Relative Humidity: 10%-93% noncondensing.
Voltage Range: 15-32 volts DC peak.
Standby Current (max. avg.): 300 μA
LED Current (max.): 6.5 mA @ 24 VDC (“ON”).
> ACCESSORIES - RELATED - CONSUMABLES :    8 Items found.
5601P
(4021)

NOTIFIER  5601P

Notifier System Sensor Mechanical Heat Detector

FST-951
(3228)

NOTIFIER  FST-951

Notifier FST-951 Series Intelligent Addressable Thermal (Heat) Detector with FlashScan and CLIP protocol systems. Two-wire SLC connection and 360° viewing angle. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FST-851 ***

FSP-951
(2038)

NOTIFIER  FSP-951

NOTIFIER by Honeywell FSP-951 Series Intelligent Plug-in Photoelectric Smoke Detector (0.5% to 4% per foot obscuration) with FlashScan and CLIP communication protocol systems. Addressable-analog communication. Optional relay, isolator and sounder bases. UL, ULC, FM and CSFM Approvals. *** Replaces FSP-851 ***

ISO-X
(3235)

NOTIFIER  ISO-X

Notifier ISO-X Fault Isolator Module for Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). Powered by SLC loop. High noise immunity. UL, FM, CSFM, MEA and BSA Approved.



 
FCO-951
(3502)

NOTIFIER  FCO-951

Notifier IntelliQuad PLUS FCO-951 Advanced Multi-Criteria Fire/CO Detector with four unique sensing elements: Carbon Monoxide (CO) electrochemical sensor, Infrared (IR) sensing measure, Photo-electric smoke detection and Thermal detection. UL listed. *** replaces FSC-851 ***



 
FSV-951R
(3229)

NOTIFIER  FSV-951R

Notifier FSV-951R Series Very Intelligent Plug-in Early Warning (VIEW) Laser Smoke Detector. 0.03% to 1.00% (CLIP) or 0.02% to 2.00% (other) sensivity. With FlashScan and CLIP protocol systems. Advanced laser light source and 360° viewing angle. Optional relay, isolator and sounder bases. UL and MEA listed. FM, CSFM, BSMI and CCCF Approved. (replaces FSL-751)

NFS-320
(2039)

NOTIFIER  NFS-320

NOTIFIER by Honeywell ONYX Series NFS-320 Intelligent Addressable Fire Alarm Control Panel. Certified for seismic and marine applications. Supports up to 159 detectors and 159 modules. Standard 80-character display and 6A power supply. Built-in Alarm, Trouble, Security and Supervisory relays, FlashScan network prototol.

U5015A1N12A
(5824)

DET-TRONICS  U5015A1N12A

Det-tronics SmokeWatch U5015 Explosion Proof Smoke Detector for smoldering and rapidly growing fires. Includes 0-20 mA output, LED and Alarm, Auxiliary and Fault relays. Aluminum Junction Box, 1x3/4" NPT entry, IP44. IECEx and FM Approved for use in Class I, Div 1 *** replaces 30-3013 ***



 
> INTELLIGENT :    20 Items found.
GNExH1N01AB1E1RN
(7280)

E2S  GNExH1N01AB1E1RN

E2S GNExH1 Heat Detector for harshest of environments. Robust corrosion proof GRP termination enclosure. Class I Zone 1, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

D2xH1VN01AB1E1RN
(7279)

E2S  D2xH1VN01AB1E1RN

E2S D2xH1 Heat Detector for harshest of environments. Stainless steel casing and hermetically sealed contacts. Class I Zone 2 and Zone 22, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

D1xH1N01MB1A1RN
(7278)

E2S  D1xH1N01MB1A1RN

E2S D1xH1 Heat Detector for harshest of environments. Stainless steel casing and hermetically sealed contacts. Certified for Zone 1 & Zone 21, Class I Zone 1 & Zone 21, Class I/Class II Div 1 & Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

OSI-R-SS
(7244)

NOTIFIER  OSI-R-SS

Notifier OSI-R-SS Reflective Imaging Beam Smoke Detector. Includes standby, fault and alarm LED indicators. 10.2 to 32 VDC. UL, ULC and FM Approved.



 
H365
(7239)

NOTIFIER  H365

Notifier H365 Addressable Intelligent Heat Detector. Two-wire SLC loop connection. Fire-resistant plastic enclosure. 15-32 VDC. UL, FM and CSFM listed.



 
SD365
(7235)

NOTIFIER  SD365

Notifier SD365 Addressable Photoelectric Smoke Detector. Two-wire SLC loop connection. LiteSpeed and CLIP protocol. UL/ULC and FM Approved.



 
STExH1N01AS1A1RN
(7281)

E2S  STExH1N01AS1A1RN

E2S STExH1 Heat Detector for harshest of environments. Explosion proof stainless steel enclosure. Zone 1 & Zone 21, Class I Zone 1 & Zone 21, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

B110LP
(7064)

NOTIFIER  B110LP

Notifier B110LP Plug-in Smoke Detector with photoelectric sensor for a wide range of combustion sources. Includes Low current draw, built-in tamper resistant base design, remote LED option, removable cover and built-in test switch. UL, ULC, FM and MEA approved.

4098-9733
(6852)

SIMPLEX TYCO  4098-9733

Simplex Tyco 4098-9733 TrueAlarm Analog Heat Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

4098-9612
(6854)

SIMPLEX TYCO  4098-9612

Simplex 4098-9612 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. 15 to 32 VDC. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

4098-9714
(6845)

SIMPLEX TYCO  4098-9714

Simplex Tyco 4098-9714 TrueAlarm Analog SSD Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

4098-9754
(6847)

SIMPLEX TYCO  4098-9754

Simplex Tyco 4098-9754 TrueAlarm Multi-Point Analog Photoelectric and Thermistor Sensor for Early Fire Detection (smoke and thermal activity). IDNet communication. Ceiling or wall mounting. UL, ULC, CSFM and FM Approved.

4098-9401
(6846)

SIMPLEX TYCO  4098-9401

Simplex Tyco 4098-9401 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

2W_-B
(6927)

NOTIFIER  2W-B

NOTIFIER by Honeywell i3 Series Photoelectric and Thermal Smoke Detector. Wide angle and dual color LED indicator. Mounting base included. UL, FM, and CSFM Approved.

4098-9601
(7076)

SIMPLEX TYCO  4098-9601

Simplex Tyco 4098-9601 TrueAlarm Photoelectric Intelligent Smoke Detector. 2.8%/ft or 3.5%/ft nominal sensivity. 2-wire or 4-wire operation. Ceiling or wall mounting. Includes alarm relay output and multi-function incator LED. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

4098-9757
(7073)

SIMPLEX TYCO  4098-9757

Simplex Tyco 4098-9757 QuickConnect2 TrueAlarm Analog Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet communications. Ceiling or wall mounting. NEMA 1. UL Approved.

FPTI-951
(6825)

NOTIFIER  FPTI-951

NOTIFIER by Honeywell FPTI-951 Multi-Criteria Photo/Thermal/Infrared Detector with FlashScan and CLIP protocol systems. Dual LEDs for 360° visibility. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FAPT-851 ***

DNR
(6866)

NOTIFIER  DNR

Notifier DNR intelligent Photoelectric Duct Smoke Detector for mounting to round or rectangular ducts. Non-Relay. Optional NEMA-4 watertight enclosure. Air velocity rating from 100 ft/min to 4,000 ft/min. Remote testing capability. UL, ULC, CSFM and FM approved.

4098-9756
(7075)

SIMPLEX TYCO  4098-9756

Simplex Tyco 4098-9756 Addressable Duct Sensor Housing with TrueAlarm Photoelectric Smoke Sensor. Includes relay, supervised output for multiple remote relays and 2 diagnostic LEDs. IDNet and MAPNET II communications. UL listed (requires separate 24 VDC fire alarm power).



 
FS-OSI-RI
(6933)

NOTIFIER  FS-OSI-RI

Notifier FS-OSI-RI Intelligent Addressable Single-ended Reflective Imaging Beam Smoke Detector suited for large open areas with high ceilings. 24 VDC. 12° field of view. Status LED indicators. UL and FM approved.



 
Cookie Notice