Notifier B110LP Plug-in Smoke Detector with photoelectric sensor for a wide range of combustion sources. Includes Low current draw, built-in tamper resistant base design, remote LED option, removable cover and built-in test switch. UL, ULC, FM and MEA approved.

B110LP   
Please Email us your request for quote   

Version

   2 Days  ]
2 Variants of base SKU
100 Series Low-Profile Plug-In Smoke Detectors

100 Series Plug-in Smoke Detectors offer superb performance and reliability in a profile which is just 2” (5.1 cm) deep. Model 2151 (photoelectric sensor) and model 2151T (photoelectric sensor with thermal) can be used with a variety of different adapter bases in several wiring configurations and voltages. Other features include: low current draw, stable performance in high air velocities, built-in tamper resistant base design, remote LED option, removable cover, and built-in test switch.

The 100 Series is designed to meet the performance criteria designated by UL. Its sensing chambers are sealed against back pressure air flow, dirt, and insects. This chamber is protected by a fine mesh screen which can be cleaned or replaced. Additional key features include a variety of mounting bases and a full line of accessories.

All 100 Series photoelectric smoke detectors contain a unique optical sensing chamber designed to sense smoke particles produced by a wide range of combustion sources. A custom integrated circuit incorporates signal processing to reduce false alarms.

Model 2151(A) photoelectric detector’s unique optical sensing chamber is engineered to sense smoke by a wide range of combustion sources. Dual electronic thermistors add 135°F fixed temperature thermal sensing on model 2151T.

Agency Listings and Approvals

These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL Listed: S911.
  • ULC Listed: CS308.
  • CSFM: 7272-1653:0122.
  • FM Approved.
  • MEA Approved: 205-94-E.
  • Maryland State Fire Marshal: #2180.

Specifications
Operating Voltage/Alarm CurrentSee Adapter Base Selec- tion Guide (see page 2).
Standby Current120uA Standby
Sensitivity1 - 3.18%/ft
Height2.0” in B401.
Diameter4.1” installed in B401; 6.2” installed in B110LP.
Shipping Weight5.2 oz.
ConstructionFlame retardant thermoplastic
TemperaturePhoto: 32°F to 120°F (0°C to 49°C).
Photo/Thermal: 32°F to 100°F (0° to 38°C).
UL Listed Velocity RangePhoto: 0–3000 fpm (0–15.2 m/s).
Humidity Range10%–93% RH non-condensing.
Smoke Detector SpacingOn smooth ceilings (as defined in NFPA 72), spacing of 30 feet (900 sq. ft.) may be used as a guide. Other spacing may be used depending on ceiling height, high air movements, and other conditions or response requirements.
Export Info
Made inMexico

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    7 Items found.
5601P
(4021)

NOTIFIER  5601P

Notifier System Sensor Mechanical Heat Detector

FST-951
(3228)

NOTIFIER  FST-951

Notifier FST-951 Series Intelligent Addressable Thermal (Heat) Detector with FlashScan and CLIP protocol systems. Two-wire SLC connection and 360° viewing angle. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FST-851 ***

FSP-951
(2038)

NOTIFIER  FSP-951

NOTIFIER by Honeywell FSP-951 Series Intelligent Plug-in Photoelectric Smoke Detector (0.5% to 4% per foot obscuration) with FlashScan and CLIP communication protocol systems. Addressable-analog communication. Optional relay, isolator and sounder bases. UL, ULC, FM and CSFM Approvals. *** Replaces FSP-851 ***

ISO-X
(3235)

NOTIFIER  ISO-X

Notifier ISO-X Fault Isolator Module for Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). Powered by SLC loop. High noise immunity. UL, FM, CSFM, MEA and BSA Approved.



 
FCO-951
(3502)

NOTIFIER  FCO-951

Notifier IntelliQuad® PLUS FCO-951 Advanced Multi-Criteria Fire/CO Detector with four unique sensing elements: Carbon Monoxide (CO) electrochemical sensor, Infrared (IR) sensing measure, Photo-electric smoke detection and Thermal detection. UL listed. *** replaces FSC-851 ***



 
FSV-951R
(3229)

NOTIFIER  FSV-951R

Notifier FSV-951R Series Very Intelligent Plug-in Early Warning (VIEW®) Laser Smoke Detector. 0.03% to 1.00% (CLIP) or 0.02% to 2.00% (other) sensivity. With FlashScan and CLIP protocol systems. Advanced laser light source and 360° viewing angle. Optional relay, isolator and sounder bases. UL and MEA listed. FM, CSFM, BSMI and CCCF Approved. (replaces FSL-751)

NFS-320
(2039)

NOTIFIER  NFS-320

NOTIFIER by Honeywell ONYX Series NFS-320 Intelligent Addressable Fire Alarm Control Panel. Certified for seismic and marine applications. Supports up to 159 detectors and 159 modules. Standard 80-character display and 6A power supply. Built-in Alarm, Trouble, Security and Supervisory relays, FlashScan network prototol. *** UNPREDICTABLE LEAD TIME ****

> INTELLIGENT :    9 Items found.
4098-9733
(6852)

TYCO  4098-9733

Tyco Simplex 4098-9733 TrueAlarm Analog Heat Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

Configure

$25.86 
4098-9714
(6845)

TYCO  4098-9714

Tyco Simplex 4098-9714 TrueAlarm Analog SSD Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

2W_-B
(6927)

NOTIFIER  2W-B

NOTIFIER by Honeywell i3 Series Photoelectric and Thermal Smoke Detector. Wide angle and dual color LED indicator. Mounting base included. UL, FM, and CSFM Approved.

4098-9601
(7076)

TYCO  4098-9601

Tyco Simplex 4098-9601 TrueAlarm Photoelectric Intelligent Smoke Detector. 2.8%/ft or 3.5%/ft nominal sensivity. 2-wire or 4-wire operation. Ceiling or wall mounting. Includes alarm relay output and multi-function incator LED. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

4098-9757
(7073)

TYCO  4098-9757

Tyco Simplex 4098-9757 QuickConnect2 TrueAlarm Analog Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet communications. Ceiling or wall mounting. NEMA 1. UL Approved.

Configure

$61.78 
FPTI-951
(6825)

NOTIFIER  FPTI-951

NOTIFIER by Honeywell FPTI-951 Multi-Criteria Photo/Thermal/Infrared Detector with FlashScan and CLIP protocol systems. Dual LEDs for 360° visibility. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FAPT-851 ***

DNR
(6866)

NOTIFIER  DNR

Notifier DNR intelligent Photoelectric Duct Smoke Detector for mounting to round or rectangular ducts. Non-Relay. Optional NEMA-4 watertight enclosure. Air velocity rating from 100 ft/min to 4,000 ft/min. Remote testing capability. UL, ULC, CSFM and FM approved.

4098-9756
(7075)

TYCO  4098-9756

Tyco Simplex 4098-9756 Addressable Duct Sensor Housing with TrueAlarm Photoelectric Smoke Sensor. Includes relay, supervised output for multiple remote relays and 2 diagnostic LEDs. IDNet and MAPNET II communications. UL listed (requires separate 24 VDC fire alarm power).



 
FS-OSI-RI
(6933)

NOTIFIER  FS-OSI-RI

Notifier FS-OSI-RI Intelligent Addressable Single-ended Reflective Imaging Beam Smoke Detector suited for large open areas with high ceilings. 24 VDC. 12° field of view. Status LED indicators. UL and FM approved.



 