Silent Knight Sk-photo-w | Intelligent | Smoke | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

SILENT KNIGHT   SK-PHOTO-W

SKU# (7670)
SILENT KNIGHT SK-PHOTO-W
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Silent Knight SK-PHOTO-W Series Addressable Photoelectric Smoke Detector. 15-32 VDC. Inludes Two wire SLC connection and remote test capability. Available with thermal sensing (135 DegreesF) and various base options. UL, FM and CSFM Approved.

UL   FM

Please Email us your request for quote   

   In Stock  ]
Description

The Silent Knight® SK-PHOTO-W Series feature a modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency.

The SK-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the SK-PHOTO Series detectors. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DNR Series duct detector housings.

FEATURES AND BENEFITS
  • Designed to meet UL 268 7th Edition
  • Sleek and stylish contemporary design
  • Stable communication technique with noise immunity
  • Addressable by device
  • Rotary, decimal addressing (Refer to the Silent Knight panel manuals for device capacity)
  • Two-wire SLC connection
  • LEDs blink every time the unit is polled
  • 360° field viewing angle of visual alarm indicators (two bi-color LEDs); LEDs blink green in Normal condition and turn on steady red in Alarm
  • Integral communications and built-in device-type identification
  • Remote test feature from the panel
  • Built-in functional test switch activated by external magnet
  • Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1)
  • Low standby current
  • Built-in tamper-resistant feature
  • Designed for direct-surface or electrical-box mounting
  • Sealed against back pressure
  • Plugs into separate base for ease of installation and maintenance
  • Expanded color options
  • SEMS screws for wiring of the separate base
  • Optional remote, single-gang LED accessory
  • Optional sounder, relay, and isolator bases
INSTALLATION

The SK-PHOTO-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector.

Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Class "B" wiring. When using relay or sounder bases, consult the SK-ISO installation sheet for device limitations between isolator modules and isolator bases.

OPERATION

Each SK-PHOTO-W Series detector uses one of the panel's addresses (total limit is panel dependent) on the Signaling Line Circuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The SK-PHOTO-W Series offers features and performance that represent the latest in smoke detector technology.

TECHNICAL SPECIFICATIONS
PHYSICAL/ENVIRONMENTAL
Sensitivity (UL Applications): 0.5% to 4.0% per foot obscuration
Sensitivity (ULC Applications): 0.5% to 3.5% per foot obscuration
Size (Detector): 2.0" (51mm) high; base determines diameter
Size (B300-6 Base): 6.1" (15.6 cm) diameter
Size (B501 Base): 4" (10.2 cm) diameter
Shipping Weight: 3.4 oz. (95 g)
Operating Temperature (SK-PHOTO-W): 32°F to 122°F (0°C to 50°C)
Operating Temperature (SK-PHOTO-T-W): 32°F to 100°F (0°C to 38°C)
Operating Temperature (SK-PHOTO-R-W in DNR/DNRW): -4°F to 158°F (-20°C to 70°C)
UL/ULC Listed Velocity Range: 0-4000 ft/min (1219.2 m/min), suitable for duct installation
Relative Humidity: 10% - 93% non-condensing
Thermal Ratings: fixed-temperature set point: 135°F (57°C)
rate-of-rise detection: 15°F (8.3°C) per minute
high temperature heat: 190°F (88°C)
ELECTRICAL ENVIRONMENTAL
Voltage Range: 15 - 32 volts DC peak
Standby Current (max. avg.): 200 μA @24 VDC (one communication every 5 seconds with LED enabled)
Max Current: 4.5 mA @24 VDC ("ON")
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531100025

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping & Handling

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> INTELLIGENT :    30 Items found.
H365
(7239)

NOTIFIER  H365

Notifier H365 Addressable Intelligent Heat Detector. Two-wire SLC loop connection. Fire-resistant plastic enclosure. 15-32 VDC. UL, FM and CSFM listed.



 
4098-5610
(7672)

SIMPLEX TYCO  4098-5610

Simplex Tyco 4098-5610 Heat Detector. Rate-of-rise and fixed temperature thermistor-based detection. False alarm resistant. UL listed to standard 268.

SD365
(7235)

NOTIFIER  SD365

Notifier SD365 Addressable Photoelectric Smoke Detector. Two-wire SLC loop connection. LiteSpeed and CLIP protocol. UL/ULC and FM Approved.



 
OSI-R-SS
(7244)

NOTIFIER  OSI-R-SS

Notifier OSI-R-SS Reflective Imaging Beam Smoke Detector. Includes standby, fault and alarm LED indicators. 10.2 to 32 VDC. UL, ULC and FM Approved.



 
D1xH1N01MB1A1RN
(7278)

E2S  D1xH1N01MB1A1RN

E2S D1xH1 Heat Detector for harshest of environments. Stainless steel casing and hermetically sealed contacts. Certified for Zone 1 & Zone 21, Class I Zone 1 & Zone 21, Class I/Class II Div 1 & Div 2. IECEx, ATEX, UL, ... more

D2xH1VN01AB1E1RN
(7279)

E2S  D2xH1VN01AB1E1RN

E2S D2xH1 Heat Detector for harshest of environments. Stainless steel casing and hermetically sealed contacts. Class I Zone 2 and Zone 22, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

4098-5601
(7528)

SIMPLEX TYCO  4098-5601

Simplex Tyco 4098-5601 Photo Detector. Rate-of-rise and fixed temperature thermistor-based detection. False alarm resistant. UL listed to standard 268.



 
STExH1N01AS1A1RN
(7281)

E2S  STExH1N01AS1A1RN

E2S STExH1 Heat Detector for harshest of environments. Explosion proof stainless steel enclosure. Zone 1 & Zone 21, Class I Zone 1 & Zone 21, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

MIX-2351AP
(7444)

MIRCOM  MIX-2351AP

Mircom MIX-2351AP(A) Intelligent Photoelectric Smoke Detector. 15-32 VDC. UL & ULC Listed.

2098-9489
(7521)

SIMPLEX TYCO  2098-9489

Simplex Tyco 2098-9489 Heat Detector for fixed temperature. Normally-Open contacts. UL rated.



 
GNExH1N01AB1E1RN
(7280)

E2S  GNExH1N01AB1E1RN

E2S GNExH1 Heat Detector for harshest of environments. Robust corrosion proof GRP termination enclosure. Class I Zone 1, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

B110LP
(7064)

NOTIFIER  B110LP

Notifier B110LP Plug-in Smoke Detector with photoelectric sensor for a wide range of combustion sources. Includes Low current draw, built-in tamper resistant base design, remote LED option, removable cover and built-in test switch. UL, ULC, FM and MEA approved.

5601P
(4021)

NOTIFIER  5601P

Notifier System Sensor Mechanical Heat Detector

4098-9733
(6852)

SIMPLEX TYCO  4098-9733

Simplex Tyco 4098-9733 TrueAlarm Analog Heat Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

4098-9612
(6854)

SIMPLEX TYCO  4098-9612

Simplex 4098-9612 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. 15 to 32 VDC. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

4098-9714
(6845)

SIMPLEX TYCO  4098-9714

Simplex Tyco 4098-9714 TrueAlarm Analog SSD Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

4098-9754
(6847)

SIMPLEX TYCO  4098-9754

Simplex Tyco 4098-9754 TrueAlarm Multi-Point Analog Photoelectric and Thermistor Sensor for Early Fire Detection (smoke and thermal activity). IDNet communication. Ceiling or wall mounting. UL, ULC, CSFM and FM Approved.

FST-951
(3228)

NOTIFIER  FST-951

Notifier FST-951 Series Intelligent Addressable Thermal (Heat) Detector with FlashScan and CLIP protocol systems. Two-wire SLC connection and 360 Degrees viewing angle. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FST-851 ***

4098-9401
(6846)

SIMPLEX TYCO  4098-9401

Simplex Tyco 4098-9401 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

2W_-B
(6927)

NOTIFIER  2W-B

NOTIFIER by Honeywell i3 Series Photoelectric and Thermal Smoke Detector. Wide angle and dual color LED indicator. Mounting base included. UL, FM, and CSFM Approved.

Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.