E2s Gnexh1n01ab1e1rn | Intelligent | Thermal | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

E2S   GNExH1N01AB1E1RN

SKU# (7280)



E2S GNExH1N01AB1E1RN
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
E2S GNExH1 Heat Detector for harshest of environments. Robust corrosion proof GRP termination enclosure. Class I Zone 1, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

UL   ATEX   IECEX   DIV 2   ZONE 1

GNExH1N01AB1E1RN   
Please Email us your request for quote   

Element guard
Temperature code
Cable entries
Options A, B, C & D reduced to 1 entry for Product version R with LED option L or C .
Stopping plug/adaptor material
Equipment tag
Product version
Versions E, H, I & R: IECEx, ATEX, UL, cUL, ULC
LED indicator

   2 Weeks  ]
251 Variants of base SKU / 30 Shown below

The E2S GNExH1 globally certified heat detector provides a comprehensive solution suitable for the harshest of environments. Featuring the D-A-F rate compensated heat detector elements with stainless steel casing and hermetically sealed contacts. The GNExH1 is approved for Class I Zone 1 AEx db eb, Ex db eb increased safety, Class I/II Div 2 applications with a high temperature version rated to 105°C plus versions certified as intrinsically safe. Global approvals include IECEx, ATEX, UL, ULC and cUL.

The robust IP66/67, Type 4/4X corrosion proof junction box enclosure is manufactured from UV stable GRP (glass reinforced polyester). The E2S GNExH1 heat detector offers a robust and reliable source for alarm initiation in the most hazardous and demanding of applications.

Features
  • Robust corrosion proof GRP (glass reinforced polyester) termination enclosure
  • Ingress protection IP66/67 Type: 4/4X
  • Threaded flame path simplifies installation and inspection
  • Multiple cable entries
  • Stopping plugs supplied
  • UL521 and CAN/ULC-S530 approved
  • EN54-5 compliant
  • D-A-F rate compensated heat detector elements
  • Versatile: various temperature settings available
  • Durable: long lasting stainless steel element shell
  • Reliable: hermetically sealed internal contact area
  • Economical: wide installation spacing reduces installation costs
  • Factory set temperature
  • Globally approved to IECEx, ATEX, UL, cUL and ULC standards
  • Version E: Zone 1/21, Class I/II Div 2
  • Version H: High temp Zone 1/21, Class I/II Div 2
  • Version I & R: Zone 0, Zone 21, Class I/II Div 1
Approvals
  • UL/cUL – File ref: E245313
  • IECEx UL 15.0003X
  • ATEX DEMKO 15ATEX1448X
  • UKCA UL21UKEX2136X
  • SIL2 compliant to IEC61508 (2010)

Specification
Enclosure:UV stable GRP (glass reinforced polyester)
Enclosure colour:Natural Red
Enclosure finish:Natural – can be painted in alternative colours
Ingress protection:IP66/67 EN50029, Type 4/4X UL50E
Cable entries:2 x M20x1.5mm – Stopping plug(s) included
Cable spec:Solid core: 0.5-2.5mm2 AWG20-12
Stranded core: 0.5-2.5mm2 AWG24-14
Terminals:DIN Rail AKZ 2.5 × 6
Max Input32Vdc: 1A, 24Vdc: 2A, 32Vac 50/60Hz: 5A – version E & H
Max Power1.25W – version E
Safety parameters:Ui=30V, Ii=500mA, Pi=1100mW, Ci=0, Li=0 – version I & R
Stopping plugs:Brass, Nickel Plated or Stainless Steel
Grounding stud:M5
Installation temp:-50° to +70°C/105°C (-58°F to +158°F/221°F)
Storage temp:-50° to +70°C/105°C (-58°F to +158°F/221°F)
Weight:2.5kg/5.5lbs
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)8531800010

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> INTELLIGENT :    24 Items found.
D2xH1VN01AB1E1RN
(7279)

E2S  D2xH1VN01AB1E1RN

E2S D2xH1 Heat Detector for harshest of environments. Stainless steel casing and hermetically sealed contacts. Class I Zone 2 and Zone 22, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

D1xH1N01MB1A1RN
(7278)

E2S  D1xH1N01MB1A1RN

E2S D1xH1 Heat Detector for harshest of environments. Stainless steel casing and hermetically sealed contacts. Certified for Zone 1 & Zone 21, Class I Zone 1 & Zone 21, Class I/Class II Div 1 & Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

OSI-R-SS
(7244)

NOTIFIER  OSI-R-SS

Notifier OSI-R-SS Reflective Imaging Beam Smoke Detector. Includes standby, fault and alarm LED indicators. 10.2 to 32 VDC. UL, ULC and FM Approved.



 
H365
(7239)

NOTIFIER  H365

Notifier H365 Addressable Intelligent Heat Detector. Two-wire SLC loop connection. Fire-resistant plastic enclosure. 15-32 VDC. UL, FM and CSFM listed.



 
SD365
(7235)

NOTIFIER  SD365

Notifier SD365 Addressable Photoelectric Smoke Detector. Two-wire SLC loop connection. LiteSpeed and CLIP protocol. UL/ULC and FM Approved.



 
STExH1N01AS1A1RN
(7281)

E2S  STExH1N01AS1A1RN

E2S STExH1 Heat Detector for harshest of environments. Explosion proof stainless steel enclosure. Zone 1 & Zone 21, Class I Zone 1 & Zone 21, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

B110LP
(7064)

NOTIFIER  B110LP

Notifier B110LP Plug-in Smoke Detector with photoelectric sensor for a wide range of combustion sources. Includes Low current draw, built-in tamper resistant base design, remote LED option, removable cover and built-in test switch. UL, ULC, FM and MEA approved.

5601P
(4021)

NOTIFIER  5601P

Notifier System Sensor Mechanical Heat Detector

4098-9733
(6852)

SIMPLEX TYCO  4098-9733

Simplex Tyco 4098-9733 TrueAlarm Analog Heat Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

4098-9612
(6854)

SIMPLEX TYCO  4098-9612

Simplex 4098-9612 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. 15 to 32 VDC. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

4098-9714
(6845)

SIMPLEX TYCO  4098-9714

Simplex Tyco 4098-9714 TrueAlarm Analog SSD Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

4098-9754
(6847)

SIMPLEX TYCO  4098-9754

Simplex Tyco 4098-9754 TrueAlarm Multi-Point Analog Photoelectric and Thermistor Sensor for Early Fire Detection (smoke and thermal activity). IDNet communication. Ceiling or wall mounting. UL, ULC, CSFM and FM Approved.

FST-951
(3228)

NOTIFIER  FST-951

Notifier FST-951 Series Intelligent Addressable Thermal (Heat) Detector with FlashScan and CLIP protocol systems. Two-wire SLC connection and 360° viewing angle. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FST-851 ***

4098-9401
(6846)

SIMPLEX TYCO  4098-9401

Simplex Tyco 4098-9401 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

2W_-B
(6927)

NOTIFIER  2W-B

NOTIFIER by Honeywell i3 Series Photoelectric and Thermal Smoke Detector. Wide angle and dual color LED indicator. Mounting base included. UL, FM, and CSFM Approved.

FSP-951
(2038)

NOTIFIER  FSP-951

NOTIFIER by Honeywell FSP-951 Series Intelligent Plug-in Photoelectric Smoke Detector (0.5% to 4% per foot obscuration) with FlashScan and CLIP communication protocol systems. Addressable-analog communication. Optional relay, isolator and sounder bases. UL, ULC, FM and CSFM Approvals. *** Replaces FSP-851 ***

4098-9601
(7076)

SIMPLEX TYCO  4098-9601

Simplex Tyco 4098-9601 TrueAlarm Photoelectric Intelligent Smoke Detector. 2.8%/ft or 3.5%/ft nominal sensivity. 2-wire or 4-wire operation. Ceiling or wall mounting. Includes alarm relay output and multi-function incator LED. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

4098-9757
(7073)

SIMPLEX TYCO  4098-9757

Simplex Tyco 4098-9757 QuickConnect2 TrueAlarm Analog Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet communications. Ceiling or wall mounting. NEMA 1. UL Approved.

FPTI-951
(6825)

NOTIFIER  FPTI-951

NOTIFIER by Honeywell FPTI-951 Multi-Criteria Photo/Thermal/Infrared Detector with FlashScan and CLIP protocol systems. Dual LEDs for 360° visibility. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FAPT-851 ***

DNR
(6866)

NOTIFIER  DNR

Notifier DNR intelligent Photoelectric Duct Smoke Detector for mounting to round or rectangular ducts. Non-Relay. Optional NEMA-4 watertight enclosure. Air velocity rating from 100 ft/min to 4,000 ft/min. Remote testing capability. UL, ULC, CSFM and FM approved.