Tyco 4906-9154 | Horn + Beacon | Indoor | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

TYCO   4906-9154

TYCO 4906-9154
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Tyco Simplex 4906-9154 Multi-tapped Speaker with Multi-Candela Synchronized Strobe (selectable intensity as 15 cd, 30 cd, 75 cd, or 110 cd). Non-Addressable. Rugged, high impact, flame retardant thermoplastic housing. Ceiling mount. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

4906-9154   
Please Email us your request for quote   

Model

   10 Weeks  ]
4 Variants of base SKU
Features Speaker/visible (S/V) notification appliances with multi-tapped speaker and multi-tapped high intensity xenon strobe with synchronized flash:
  • Rugged, high impact, flame retardant thermoplastic housings are available for wall or ceiling mount
  • Operation is compatible with ADA requirements (see Wall mount installation reference)
Wall mount S/V features:
  • Housings are available in red or white with clear lens with contrasting white or red FIRE lettering
  • Covers are available separately to convert housing color
Ceiling mount S/V features:
  • Housing is white with clear lens
  • Red FIRE lettering is printed on two sides
Audible notification appliance (speaker):
  • High quality voice and tone reproduction with taps for 1/4 W, 1/2 W , 1 W, or 2 W, at 25 VRMS or 70.7 VRMS
  • Capacitor input for connection to supervised notification appliance circuits
  • Speakers are wired separately from strobe wiring
  • UL listed to Standard 1480 and ULC-S541*
  • Compliant with NFPA 72, 520 Hz Low Frequency Signal Requirements for Sleeping Areas
Visible notification appliance (strobe):
  • 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing
  • Strobes are activated from NACs selected to provide Simplex strobe synchronization signals or from separate strobe Synchronization
  • Modules that are available for Class B or Class A operation
  • Regulated circuit design ensures consistent flash output and provides controlled inrush current
  • UL listed to Standard 1971 and ULC-S526*
Options for wall mounted S/Vs:
  • Red or white adapters to cover surface mounted electrical boxes
  • Red adapter for mounting to 2975-9145 boxes
  • Red wire guard
Description Multi-Candela TrueAlert S/Vs with speaker and synchronized strobe

Provide convenient installation to standard electrical boxes with extensions. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. You can select each model for strobe intensity output. This minimizes on-site model inventory and easily accommodates changes encountered during construction.

Wall mount

S/V housings are a one-piece assembly, including lens, that mounts to a 4 in. square electrical box with extension, see Wall mount installation reference. You can quickly remove the cover with a tool and covers are available separately for color conversion.

Ceiling mount

S/Vs also install using 4 in. electrical boxes with an extension. See Ceiling mount S/V installation reference and 2905-9946 tile bridge dimensions.

Strobe Intensity Selection

During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens.

Synchronized strobes Multiple strobes

When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these S/Vs are activated by NACs that provide the Simplex synchronization format. For additional information, refer to data sheet S4905-0003.

Strobe application selection

Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA).

S/V Specifications
Common Specifications
Environmental32°F to 122°F or 0°C to 50°C; 10% to 93%, non-condensing at 100°F or 38°C
ConnectionsTerminal blocks for 18 AWG to 12 AWG or 0.82 mm to 3.31 mm ; two wires for each terminal for in/out wiring
Speaker Specifications
Input voltage25 VRMS or 70.7 VRMS, see Note 1
Power taps1/4 W, 1/2 W, 1 W, and 2 W
Frequency ResponseFire Alarm: 400 Hz to 4000 Hz
General signaling: 125 kHz to 12 kHz
Speaker output Ratings @ 10 ft or 3 m (see Note 1)1/4 W: 76 dBA
1/2 W: 79 dBA
1 W: 82 dBA
2 W: 85 dBA
Polar Dispersion Reference (per ULC-S541 Anechoic Chamber Testing)Attenuation: -3 dB
Angle: +/- 30° off-axis
Attenuation: -6 dB
Angle: +/- 55° off-axis
Strobe Specifications
Rated voltage rangeRegulated 24 VDC; 16 VDC to 33 VDC, see Note 2
Flash rate and synchronized NAC loading1 Hz; with up to 35 synchronized strobes maximum for each NAC
Housing dimensionsSpeaker housing = 7 1/2 in. or 191 mm diameter, 1/2 in. deep or 13 mm; lens protrusion above speaker housing = 2 5/8 in. or 67 mm; depth into box = 2 3/4 in. or 70 mm
Maximum RMS Current rating per strobe setting15 cd: 75 mA
30 cd: 125 mA
75 cd: 233 mA
110 cd: 316 mA
Reference RMS currents at other voltages18 VDC
15 cd: 67 mA
30 cd: 111 mA
75 cd: 207 mA
110 cd: 281 mA
24 VDC
15 cd: 50 mA
30 cd: 83 mA
75 cd: 155 mA
110 cd: 211 mA

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
4906-9127
(7079)

TYCO  4906-9127

Tyco Simplex 4906-9127 Multi-Candela Audible/Visible Notification with high output Xenon Strobe and Synchronized Flash. Non-Addressable. Wall or ceiling mount. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

> HORN + BEACON :    91 Items found.
D1xC1X10RDC024AB1A1R/A
(4416)

E2S  D1xC1X10RDC024AB1A1R/A

E2S D1xC1X10R Radial Alarm Horn 117dB(A) and 10 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xC2X10RDC024AB1A1R/A
(4420)

E2S  D1xC2X10RDC024AB1A1R/A

E2S D1xC2X10R Radial Alarm Horn 118dB(A) and 10 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xC2X10FDC024AB1A1R/A
(4419)

E2S  D1xC2X10FDC024AB1A1R/A

E2S D1xC2X10F Alarm Horn 125dB(A) and 10 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

CU1S_W_024F06RNNNN1BN
(4160)

MEDC  CU1SW024F06RNNNN1BN

MEDC CU1 Combination Unit (Beacon Sounder) with 27 output tones. Weatherproof only version. Up to 116 dB(A), IP66 and 67, intended for use in potentially explosive gas atmospheres. -50C to +50C.

Configure

$2,007.50 
XB12-DB3BWN0481BNNNNN
(1620)

MEDC  XB12-DB3BWN0481BNNNNN

MEDC XB12/DB3B Strobe/Horn Combination Unit mounted on a sturdy, drilled, painted, stainless steel, 2 way baseplate. Heavy Duty Industrial & Marine Xenon 10J. Sounder up to 110dB(A). IP66 and IP67.

Configure

$2,198.99 
CU1S_B_024F06RNNNN1BN
(1598)

MEDC  CU1SB024F06RNNNN1BN

MEDC CU1 Combination Unit (Beacon Sounder) with 27 output tones, Zone 1, Zone 2 and non-Ex use, Up to 116 dB(A), IP66 and 67, intended for use in potentially explosive gas atmospheres. -50C to +50C. Available Certifications: ATEX, IECEx, CENELEC, GOST R and K, BASEEFA and Inmetro.

Configure

$2,230.51 
CU1H_B_024F06RNNNN1BN
(4161)

MEDC  CU1HB024F06RNNNN1BN

MEDC CU1 Combination Unit (Beacon Sounder) with 27 output tones, Zone 1, Zone 2 and non-Ex use, Up to 116 dB(A), IP66 and 67, intended for use in potentially explosive gas atmospheres. High Temperature version. -50C to +60C. Available Certifications: ATEX, IECEx, CENELEC, GOST R and K, BASEEFA and Inmetro.

Configure

$2,342.03 
STEXC1X05FDC012AS2A1R/A
(6455)

E2S  STEXC1X05FDC012AS2A1R/A

E2S STExC1X05F 117dB(A) Alarm Horn & 5 Joule Xenon Strobe Beacon with 1Hz, 1.5Hz and double flash rates. IP66 corrosion proof 316L stainless steel enclosure with guard. 3 x M20 ISO entries. Suitable for For All Zone 1, 2, 21 & 22. IECEx and ATEX Approved.

STEXC1X05RDC012AS2A1R/A
(6456)

E2S  STEXC1X05RDC012AS2A1R/A

E2S STExC1X05R 115dB(A) Radial Alarm Horn & 5 Joule Xenon Strobe Beacon with 1Hz, 1.5Hz and double flash rates. IP66 corrosion proof 316L stainless steel enclosure with guard. 3 x M20 ISO entries. Suitable for For All Zone 1, 2, 21 & 22. IECEx and ATEX Approved.

SM87HXB+DB3D024RRA1
(4403)

MEDC  SM87HXB+DB3D024RRA1

MEDC SM87HXB/DB3 Strobe/Horn Combination Unit mounted on a sturdy, drilled, painted, stainless steel, 2 way baseplate. Explosionproof Xenon 5J; Sounder up to 115dB(A). ATEX Certified Ex II 2GD, Ex d IIC T4/T5 Gb, Ex tb IIIC T100°C/T135°C Db. IP66 and IP67. LM25.

SM87HXB+DB3BUL024RR3B
(1619)

MEDC  SM87HXB+DB3BUL024RR3B

MEDC SM87HXB/DB3B Strobe/Horn Combination Unit mounted on a sturdy, drilled, painted, stainless steel, 2 way baseplate. Explosionproof Xenon 5J; Sounder up to 122dB(A). Class I Div 1, IP66 and IP67. LM25. Available certifications: UL.

Configure

$3,581.33 
Page: 1 | 2 | 3 | 4 | 5 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.