Tyco 4906-9154 | Horn + Beacon | Indoor | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

TYCO   4906-9154

TYCO 4906-9154
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Tyco Simplex 4906-9154 Multi-tapped Speaker with Multi-Candela Synchronized Strobe (selectable intensity as 15 cd, 30 cd, 75 cd, or 110 cd). Non-Addressable. Rugged, high impact, flame retardant thermoplastic housing. Ceiling mount. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

4906-9154   
Please Email us your request for quote   

Model

   10 Weeks  ]
4 Variants of base SKU
Features Speaker/visible (S/V) notification appliances with multi-tapped speaker and multi-tapped high intensity xenon strobe with synchronized flash:
  • Rugged, high impact, flame retardant thermoplastic housings are available for wall or ceiling mount
  • Operation is compatible with ADA requirements (see Wall mount installation reference)
Wall mount S/V features:
  • Housings are available in red or white with clear lens with contrasting white or red FIRE lettering
  • Covers are available separately to convert housing color
Ceiling mount S/V features:
  • Housing is white with clear lens
  • Red FIRE lettering is printed on two sides
Audible notification appliance (speaker):
  • High quality voice and tone reproduction with taps for 1/4 W, 1/2 W , 1 W, or 2 W, at 25 VRMS or 70.7 VRMS
  • Capacitor input for connection to supervised notification appliance circuits
  • Speakers are wired separately from strobe wiring
  • UL listed to Standard 1480 and ULC-S541*
  • Compliant with NFPA 72, 520 Hz Low Frequency Signal Requirements for Sleeping Areas
Visible notification appliance (strobe):
  • 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing
  • Strobes are activated from NACs selected to provide Simplex strobe synchronization signals or from separate strobe Synchronization
  • Modules that are available for Class B or Class A operation
  • Regulated circuit design ensures consistent flash output and provides controlled inrush current
  • UL listed to Standard 1971 and ULC-S526*
Options for wall mounted S/Vs:
  • Red or white adapters to cover surface mounted electrical boxes
  • Red adapter for mounting to 2975-9145 boxes
  • Red wire guard
Description Multi-Candela TrueAlert S/Vs with speaker and synchronized strobe

Provide convenient installation to standard electrical boxes with extensions. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. You can select each model for strobe intensity output. This minimizes on-site model inventory and easily accommodates changes encountered during construction.

Wall mount

S/V housings are a one-piece assembly, including lens, that mounts to a 4 in. square electrical box with extension, see Wall mount installation reference. You can quickly remove the cover with a tool and covers are available separately for color conversion.

Ceiling mount

S/Vs also install using 4 in. electrical boxes with an extension. See Ceiling mount S/V installation reference and 2905-9946 tile bridge dimensions.

Strobe Intensity Selection

During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens.

Synchronized strobes Multiple strobes

When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these S/Vs are activated by NACs that provide the Simplex synchronization format. For additional information, refer to data sheet S4905-0003.

Strobe application selection

Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA).

S/V Specifications
Common Specifications
Environmental32°F to 122°F or 0°C to 50°C; 10% to 93%, non-condensing at 100°F or 38°C
ConnectionsTerminal blocks for 18 AWG to 12 AWG or 0.82 mm to 3.31 mm ; two wires for each terminal for in/out wiring
Speaker Specifications
Input voltage25 VRMS or 70.7 VRMS, see Note 1
Power taps1/4 W, 1/2 W, 1 W, and 2 W
Frequency ResponseFire Alarm: 400 Hz to 4000 Hz
General signaling: 125 kHz to 12 kHz
Speaker output Ratings @ 10 ft or 3 m (see Note 1)1/4 W: 76 dBA
1/2 W: 79 dBA
1 W: 82 dBA
2 W: 85 dBA
Polar Dispersion Reference (per ULC-S541 Anechoic Chamber Testing)Attenuation: -3 dB
Angle: +/- 30° off-axis
Attenuation: -6 dB
Angle: +/- 55° off-axis
Strobe Specifications
Rated voltage rangeRegulated 24 VDC; 16 VDC to 33 VDC, see Note 2
Flash rate and synchronized NAC loading1 Hz; with up to 35 synchronized strobes maximum for each NAC
Housing dimensionsSpeaker housing = 7 1/2 in. or 191 mm diameter, 1/2 in. deep or 13 mm; lens protrusion above speaker housing = 2 5/8 in. or 67 mm; depth into box = 2 3/4 in. or 70 mm
Maximum RMS Current rating per strobe setting15 cd: 75 mA
30 cd: 125 mA
75 cd: 233 mA
110 cd: 316 mA
Reference RMS currents at other voltages18 VDC
15 cd: 67 mA
30 cd: 111 mA
75 cd: 207 mA
110 cd: 281 mA
24 VDC
15 cd: 50 mA
30 cd: 83 mA
75 cd: 155 mA
110 cd: 211 mA

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
4906-9127
(7079)

TYCO  4906-9127

Tyco Simplex 4906-9127 Multi-Candela Audible/Visible Notification with high output Xenon Strobe and Synchronized Flash. Non-Addressable. Wall or ceiling mount. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

> HORN + BEACON :    91 Items found.
HAB121RTHDC012G/R
(3651)

E2S  HAB121RTHDC012G/R

E2S HAB121RTH Electronic Siren, Buzzer, Claxon and Bell 121dB(A). Includes beacon with 40W halogen bulb. Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 12VDC. IP66.

AL121HDC024R/A
(4431)

E2S  AL121HDC024R/A

E2S AL121H Alarm Horn Sounder (A121) 126dB(A) and High Output LED Beacon (L101H). 115VAC. Stainless steel fixings. Programmable version available. IP66. VdS and GOST-R Approved. Optional UL version.

AL121XDC024R/R
(3556)

E2S  AL121XDC024R/R

E2S AL121X Alarm Horn Sounder (A121) 126dB(A) and 5 Joule Xenon Strobe Beacon (L101X). 115VAC, 230VAC, 24VAC, 24VDC or 48VDC Versions. Stainless steel fixings. Programmable version available. IP66. VdS and GOST-R Approved. Optional UL version.

AB121LDADC024G/A
(3604)

E2S  AB121LDADC024G/A

E2S AB121LDA Alarm Sounder 126dB(A) and LED Beacon with 9 user selectable operation modes. Heavy duty sounder. Automatic synchronisation. Stainless Steel fixings. 24VDC, 48VDC, 115 VAC or 230VAC Versions. IP65. VdS Approved.

HAL121XAC115R/A
(5135)

E2S  HAL121XAC115R/A

E2S HAL121X Electronic Siren, Buzzer, Claxon and Bell 121dB(A) and 5 Joule Xenon Beacon. 24VDC, 115VAC or 230VAC Versions. Stainless steel fixings. IP56. GOST-R Approved.

REM-1L-R-FLASH
(5115)

COOL AIR  REM-1L-R-FLASH

Cool Air Indoor/Outdoor Remote Alarm Light & Horn Unit for LBW-50 or LBW-420 Ammonia Leak Detector. Provides a brighter light via a combination of long-life LEDs and a daybright lens. NEMA 4X box, light, horn, 24VDC. Output is 99db at 1 meter.

Configure

$541.20 
HMCA11205DC024G-AM
(3653)

E2S  HMCA11205DC024G-AM

E2S HMCA121-05 Electronic Siren, Buzzer, Claxon and Bell 122dB(A). With 5 Joules Xenon Beacon. Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel guard and fixings. 24VDC or 230VAC Versions. IP66 & IP67. GOST-R approved.

MC1LD2FDC024AN1A1GA
(6826)

E2S  MC1LD2FDC024AN1A1GA

E2S MC1LD2F Alarm Sounder 117dB(A) and LED Beacon with 7 user selectable operation modes. High output sounder with a robust, fire retardant, IP66 & IP67 housing. Suitable for harsh environments. Stainless Steel fixings and guard. 24VDC, 115VAC or 230VAC Versions. CE, RMRS Approvals.

MCA112L1DC024G-AM
(3610)

E2S  MCA112L1DC024G-AM

E2S MCA112-L1 Alarm Sounder 119dB(A) and LED Beacon with 9 user selectable operation modes. High output sounder with a robust, fire retardant, IP66 & IP67 housing. Suitable for harsh environments. Stainless Steel fixings and guard. 24VDC, 24VAC, 115 VAC or 230VAC Versions. GOST-R Approved. ***phased out, replaced by MC1LD2F ***

HO-REM-HU-ST-24
(3696)

COOL AIR  HO-REM-HU-ST-24

Cool Air High Output Remote Alarm Horn & Strobe Unit for LBW-50 or LBW-420 Ammonia Leak Detector. NEMA 4X box. Max 117 dB(A), No Cable.

Configure

$582.20 
DL105HDC024G/A
(6463)

E2S  DL105HDC024G/A

E2S DL105H 112dB(A) Alarm Sounder & 120cd LED Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

DL105XDC012G/A
(6464)

E2S  DL105XDC012G/A

E2S DL105X 112dB(A) Alarm Sounder & 5 Joule Xenon Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

DL112XDC012G/A
(6466)

E2S  DL112XDC012G/A

E2S DL112X 119dB(A) Alarm Sounder & 5 Joule Xenon Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

DL112HDC024G/A
(6465)

E2S  DL112HDC024G/A

E2S DL112H 119dB(A) Alarm Sounder & 120cd LED Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

MC1X05FDC024CN1A1G/Y
(6925)

E2S  MC1X05FDC024CN1A1G/Y

E2S MC1X05F Alarm Sounder 117dB(A) and 5J Xenon Beacon with 1Hz flash rate. High output sounder with a robust, fire retardant, IP66 & IP67 housing. Suitable for harsh environments. Stainless Steel fixings and guard. 12VDC, 24VDC, 48VDC, 115 VAC or 230VAC Versions. GOST-R Approved.

E2XC1X05RAC115CN1A1B/A
(6420)

E2S  E2XC1X05RAC115CN1A1B/A

E2S E2xC1X05R Combination Radial Horn & 5 Joule Xenon Beacon for hazardous locations. Up to 114dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

E2XC1LD2FAC115CN1A1B/A
(6421)

E2S  E2XC1LD2FAC115CN1A1B/A

E2S E2xC1LD2F Combination Alarm Horn & LED Beacon for hazardous locations. Up to 116dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

E2XC1LD2RAC115CN1A1B/A
(6422)

E2S  E2XC1LD2RAC115CN1A1B/A

E2S E2xC1LD2R Combination Radial Horn & LED Beacon for hazardous locations. Up to 114dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

E2XC1X05FAC115CN1A1B/A
(6419)

E2S  E2XC1X05FAC115CN1A1B/A

E2S E2xC1X05F Combination Alarm Horn & 5 Joule Xenon Beacon for hazardous locations. Up to 116dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

D2XC1X05DC024CN1A1R/C
(4427)

E2S  D2XC1X05DC024CN1A1R/C

E2S D2xC1X05 Alarm Horn Sounder 116dB(A) and 5 Joule Xenon Strobe Beacon. Low current consumption and high SPL. Type 4/4X, IP66 enclosure. Suitable for the harshest of hazardous location environments. 4 remotely selectable alarm stages. 64 alarm tone frequencies. UL approved for Class I Div 2 and Class II Div 2. IECEx and ATEX Approved.

Page: 1 | 2 | 3 | 4 | 5 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.