Tyco 4906-9154 | Horn + Beacon | Indoor | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

TYCO   4906-9154

TYCO 4906-9154
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Tyco Simplex 4906-9154 Multi-tapped Speaker with Multi-Candela Synchronized Strobe (selectable intensity as 15 cd, 30 cd, 75 cd, or 110 cd). Non-Addressable. Rugged, high impact, flame retardant thermoplastic housing. Ceiling mount. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

4906-9154   
Please Email us your request for quote   

Model

   10 Weeks  ]
4 Variants of base SKU
Features Speaker/visible (S/V) notification appliances with multi-tapped speaker and multi-tapped high intensity xenon strobe with synchronized flash:
  • Rugged, high impact, flame retardant thermoplastic housings are available for wall or ceiling mount
  • Operation is compatible with ADA requirements (see Wall mount installation reference)
Wall mount S/V features:
  • Housings are available in red or white with clear lens with contrasting white or red FIRE lettering
  • Covers are available separately to convert housing color
Ceiling mount S/V features:
  • Housing is white with clear lens
  • Red FIRE lettering is printed on two sides
Audible notification appliance (speaker):
  • High quality voice and tone reproduction with taps for 1/4 W, 1/2 W , 1 W, or 2 W, at 25 VRMS or 70.7 VRMS
  • Capacitor input for connection to supervised notification appliance circuits
  • Speakers are wired separately from strobe wiring
  • UL listed to Standard 1480 and ULC-S541*
  • Compliant with NFPA 72, 520 Hz Low Frequency Signal Requirements for Sleeping Areas
Visible notification appliance (strobe):
  • 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing
  • Strobes are activated from NACs selected to provide Simplex strobe synchronization signals or from separate strobe Synchronization
  • Modules that are available for Class B or Class A operation
  • Regulated circuit design ensures consistent flash output and provides controlled inrush current
  • UL listed to Standard 1971 and ULC-S526*
Options for wall mounted S/Vs:
  • Red or white adapters to cover surface mounted electrical boxes
  • Red adapter for mounting to 2975-9145 boxes
  • Red wire guard
Description Multi-Candela TrueAlert S/Vs with speaker and synchronized strobe

Provide convenient installation to standard electrical boxes with extensions. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. You can select each model for strobe intensity output. This minimizes on-site model inventory and easily accommodates changes encountered during construction.

Wall mount

S/V housings are a one-piece assembly, including lens, that mounts to a 4 in. square electrical box with extension, see Wall mount installation reference. You can quickly remove the cover with a tool and covers are available separately for color conversion.

Ceiling mount

S/Vs also install using 4 in. electrical boxes with an extension. See Ceiling mount S/V installation reference and 2905-9946 tile bridge dimensions.

Strobe Intensity Selection

During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens.

Synchronized strobes Multiple strobes

When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these S/Vs are activated by NACs that provide the Simplex synchronization format. For additional information, refer to data sheet S4905-0003.

Strobe application selection

Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA).

S/V Specifications
Common Specifications
Environmental32°F to 122°F or 0°C to 50°C; 10% to 93%, non-condensing at 100°F or 38°C
ConnectionsTerminal blocks for 18 AWG to 12 AWG or 0.82 mm to 3.31 mm ; two wires for each terminal for in/out wiring
Speaker Specifications
Input voltage25 VRMS or 70.7 VRMS, see Note 1
Power taps1/4 W, 1/2 W, 1 W, and 2 W
Frequency ResponseFire Alarm: 400 Hz to 4000 Hz
General signaling: 125 kHz to 12 kHz
Speaker output Ratings @ 10 ft or 3 m (see Note 1)1/4 W: 76 dBA
1/2 W: 79 dBA
1 W: 82 dBA
2 W: 85 dBA
Polar Dispersion Reference (per ULC-S541 Anechoic Chamber Testing)Attenuation: -3 dB
Angle: +/- 30° off-axis
Attenuation: -6 dB
Angle: +/- 55° off-axis
Strobe Specifications
Rated voltage rangeRegulated 24 VDC; 16 VDC to 33 VDC, see Note 2
Flash rate and synchronized NAC loading1 Hz; with up to 35 synchronized strobes maximum for each NAC
Housing dimensionsSpeaker housing = 7 1/2 in. or 191 mm diameter, 1/2 in. deep or 13 mm; lens protrusion above speaker housing = 2 5/8 in. or 67 mm; depth into box = 2 3/4 in. or 70 mm
Maximum RMS Current rating per strobe setting15 cd: 75 mA
30 cd: 125 mA
75 cd: 233 mA
110 cd: 316 mA
Reference RMS currents at other voltages18 VDC
15 cd: 67 mA
30 cd: 111 mA
75 cd: 207 mA
110 cd: 281 mA
24 VDC
15 cd: 50 mA
30 cd: 83 mA
75 cd: 155 mA
110 cd: 211 mA

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
4906-9127
(7079)

TYCO  4906-9127

Tyco Simplex 4906-9127 Multi-Candela Audible/Visible Notification with high output Xenon Strobe and Synchronized Flash. Non-Addressable. Wall or ceiling mount. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

> HORN + BEACON :    91 Items found.
GDS-450X-1-0/0/1-1-0
(4712)

GDS  GDS-450X-1-0/0/1-1-0

GDS GDS-450X Alarm Station Annunciator with Two Strobes and Horn. Corrosion-resistant stainless steel mounting plate. 24VDC or 110VAC configurations. Suitable for Class I Division 2 Hazardous Areas.

BEXCTS11005DR230AC-GN
(4406)

E2S  BEXCTS11005DR230AC-GN

E2S BExCTS110-05 flameproof telephone initiated and Omni-directional Alarm Horn 117dB(A) and Green Xenon Beacon. 32 selectable sounds. LM6 aluminium enclosure. 230 VAC.Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX, IECEx and GOST-R Approved.

D2xC2LD2DC024CN0H1R/C
(6414)

E2S  D2xC2LD2DC024CN0H1R/C

E2S D2xC2LD2-H Haz Loc Synchronized Horn & LED Beacon tested to UL464 & UL1971. 24VDC. Up to 116dB(A). Up to 180cd. 2 × 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.



 
D2xC2LD2DC024CN1A1R/C
(6415)

E2S  D2xC2LD2DC024CN1A1R/C

E2S D2xC2LD2 Haz Loc Horn & LED Beacon tested to UL1638. Up to 116dB(A). Up to 180cd. 2 × 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

D2XC1X10DC024CN1A1R/C
(4428)

E2S  D2XC1X10DC024CN1A1R/C

E2S D2xC1X10 Alarm Horn Sounder 116dB(A) and 10 Joule Xenon Strobe Beacon. Low current consumption and high SPL. Type 4/4X, IP66 enclosure. Suitable for the harshest of hazardous location environments. 4 remotely selectable alarm stages. 64 alarm tone frequencies. UL approved for Class I Div 2 and Class II Div 2. IECEx and ATEX Approved.

D2xC2XH1DC024CN0A1R/C
(6416)

E2S  D2xC2XH1DC024CN0A1R/C

E2S D2xC2XH1 auto-synchronizing Horn & 5 Joule Xenon Strobe tested to UL464 & UL1971. 24VDC. Up to 116dB(A). Up to 250cd. 2 × 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.



 
BEXDCS11005D_24DC-AM
(3674)

E2S  BEXDCS11005D24DC-AM

E2S BExDCS110-05D flameproof Alarm Horn 117dB(A) and 5 Joule Xenon Strobe. LM6 aluminium enclosure. Suitable for Zone 1, 2, 21 & 22 applications. Two M20 cable entries. IP66/67. ATEX, IECEx and GOST-R (1ExdIICT4) Approved.

D2xC2XH2DC024CN0A1R/C
(6417)

E2S  D2xC2XH2DC024CN0A1R/C

E2S D2xC2XH2 auto-synchronizing Horn & 10 Joule Xenon Strobe tested to UL464 & UL1971. 24VDC. Up to 116dB(A). Up to 500cd. 2 × 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.



 
BEXDCS11005DR115AC-RD
(4405)

E2S  BEXDCS11005DR115AC-RD

E2S BExDCS110-05D-R flameproof Alarm Horn 117dB(A) and 5 Joule Xenon Red Strobe. Omni-directional. 115 VAC. LM6 aluminium enclosure. Suitable for Zone 1, 2, 21 & 22 applications. Two M20 cable entries. IP66/67. ATEX, IECEx and GOST-R (1ExdIICT4) Approved.

BEXDCS110L1D_24DC-AM
(3677)

E2S  BEXDCS110L1D24DC-AM

E2S BExDCS110-L1D flameproof Alarm Horn 117dB(A) and LED Beacon with 9 user selectable operation modes. LM6 aluminium enclosure. Suitable for Zone 1, 2, 21 & 22 applications. Two M20 cable entries. IP66/67. ATEX, IECEx, GOST-R (1ExdIICT4) and SIL1 Approved.

XB13-DB3BWN0481BNNNNN
(6047)

MEDC  XB13-DB3BWN0481BNNNNN

MEDC XB13/DB3B Strobe/Horn Combination Unit mounted on a sturdy, drilled, painted, stainless steel, 2 way baseplate. Heavy Duty Industrial & Marine Xenon 10J. Sounder up to 110dB(A). IP66 and IP67.

Configure

$1,557.17 
BEXCS11005DPRDC012AB1A1R/A
(3675)

E2S  BEXCS11005DPRDC012AB1A1R/A

E2S BExCS110-05-R flameproof Omnidirectional Horn 117dB(A) and 5 Joule Xenon Strobe. LM6 aluminium enclosure. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX, IECEx and GOST-R (1ExdIICT4) Approved.

BEXCS110L2DPFDC024AB1A1R/A
(3676)

E2S  BEXCS110L2DPFDC024AB1A1R/A

E2S BExCS110-L2D flameproof Alarm Horn 117dB(A) and LED Beacon with 7 user selectable operation modes. LM6 aluminium enclosure. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX and IECEx Approvals.

BEXCS11005DPFDC012AB1A1R/A
(3673)

E2S  BEXCS11005DPFDC012AB1A1R/A

E2S BExCS110-05D flameproof Alarm Horn 117dB(A) and 5 Joule Xenon Strobe. LM6 aluminium enclosure. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX, IECEx and GOST-R (1ExdIICT4) Approved.

BEXCS110L2DPRDC024AB1A1R/A
(4407)

E2S  BEXCS110L2DPRDC024AB1A1R/A

E2S BExCS110-L2-R flameproof Omni-directional Alarm Horn 117dB(A) and Red LED Beacon with 7 user selectable operation modes. LM6 aluminium enclosure. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX and IECEx approvals.

D1xC1X05FDC024AB1A1R/A
(4413)

E2S  D1xC1X05FDC024AB1A1R/A

E2S D1xC1X05F Alarm Horn 117dB(A) and 5 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xC1X05RDC024AB1A1R/A
(4414)

E2S  D1xC1X05RDC024AB1A1R/A

E2S D1xC1X05R Radial Alarm Horn 115dB(A) and 5 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xC2X05RDC024AB1A1R/A
(4418)

E2S  D1xC2X05RDC024AB1A1R/A

E2S D1xC2X05R Radial Alarm Horn 118dB(A) and 5 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xC2X05FDC024AB1A1R/A
(4417)

E2S  D1xC2X05FDC024AB1A1R/A

E2S D1xC2X05F Alarm Horn 125dB(A) and 5 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xC1X10FDC024AB1A1R/A
(4415)

E2S  D1xC1X10FDC024AB1A1R/A

E2S D1xC1X10F Alarm Horn 117dB(A) and 10 Joule Xenon Strobe. High output. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

Page: 1 | 2 | 3 | 4 | 5 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.