Cool Air Lbw-50-rlv | Ammonia | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

COOL AIR   LBW-50-RLV

COOL AIR LBW-50-RLV
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Cool Air Ammonia Relief Line Vent Gas Detector LBW-RLV for continuos monitoring of Ammonia (NH3) 25-800ppm refrigeration gas emergency vent line headers. NEMA 4 weatherproof enclosure. 2 Alarm and 1 Auxiliary relays, 2 wires for power. 4 wires for control signals. 100 to 240VAC, 50/60 Hz, 16 VAC, or 24 VDC UL Listed
Includes TB-100 test bottle

LBW-50-RLV   
1,332.50

Backup Battery
Remote Sensor
Alarm
Washdown Utility Tube

 In Stock  ]

Housed in a durable, weatherproof enclosure (NEMA 4 rated), the Ammonia Relief Line Gas Detector provides reliable detection of refrigeration system overpressure or relief valve leakage.

The unit contains a voltage stabilized amplifier circuit which enables detection of ammonia gas in the ammonia emergency relief line. Sensor trip point is adjustable from 25 ppm to 800 ppm.

18 gauge, 6 conductor wire, 2 wires for power and 4 wires for control signals. Available in 115/230 VAC, 50/60 Hz, or 16 VAC if you use the Central Supervisory Control Panel. Connect all wires to factory wired terminal strip.

Features
  • NO SENSOR DEPLETION during an ammonia leak, from background ammonia vapors, or during testing &/or calibration.
  • Affordable
  • Dependable
  • One year warranty
  • Rugged, weatherproof enclosure (NEMA 4)
  • High quality, UL listed components
  • Virtually maintenance free
  • Can be tied into existing security alarm system
  • Easy to adjust calibration
  • Sensitivity adjustable from 25 ppm to 800 ppm
Warranty

12 months warranty on workmanship from date of sale. Cool Air Incorporated reserves the right to make changes in the design of this unit without notification.

Coolair Relief Line Gas Detector Diagram
Coolair Relief Line Gas Detector Diagram

GENERAL SPECIFICATIONS
Size4-1/8"H x 6-7/8"W x 5-1/4"D.
Weight 4 lbs.
Power input115/230 VAC, 50/60 Hz, or 16 VAC.
Sensitivityas determined by trip point settings at remote detectors, adjustable from 25 ppm to 800 ppm concentration of NH3. Early warning alarm trip point at remote detectors is set at 25 ppm (not adjustable).
High and Low Temperature Set Point Range-50°F to 50°F (No heater required)
General AccuracyDependent on the calibration solution which is typically +/- 5%
Linearity+/-1% of full scale. Full scale being defined as the calibrated solution concentration
Sensor Life Span 10 Years plus. Sensor operation and life span are not affected by background NH3 gas
Agency ApprovalsTUV Rheinland USA/CANADA (tested to UL 61010-1:2004 R7.05; CAN/CSA-C22.2 61010-1:2004)
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    10 Items found.
(6213)

COOL AIR  EC-CAL-ADPT

Cool Air calibration cup adaptor for COOL Air Ammonia Electrochemical sensors, to be used with 0.3 LPM flow regulator.



$21.75 
TB-100
(919)

COOL AIR  TB-100

Cool Air Replacement Test Bottle for LBW-50 or LBW-420 Ammonia Leak Detectors, 100 ppm NH3.



$45.50 
LBW-BB
(1559)

COOL AIR  LBW-BB

Backup Batery for Cool Air LBW-50, LBW-RLV, OR LBW-420



$63.70 
NH3-S-RPL
(4456)

COOL AIR  NH3-S-RPL

Cool Air Replacement Solid State Ammonia Sensor for LBW-50, LBW-420, Watchman and RLV Ammonia Leak Detectors.



$122.85 
LBW-420-RS-050
(913)

COOL AIR  LBW-420-RS-050

Cool Air Remote Sensor for LBW-420 Ammonia Leak Detector. Comes with NEMA 4X box, circuit board with sensor socket and 50 feet of cable.

Configure

$262.40 
NH3-50-EC
(6211)

COOL AIR  NH3-50-EC

Cool Air Replacement Electrochemical Ammonia Sensor for LBW-50 Ammonia Leak Detectors.



$282.90 
DM-LCD
(3697)

COOL AIR  DM-LCD

Cool Air LCD door monitor remote display for PPM ammonia concentration from a single LBW-420/420-1 Detector. 4-20 mA output. 24 VDC.

Configure

$360.80 
REM-1L-R-FLASH
(5115)

COOL AIR  REM-1L-R-FLASH

Cool Air Indoor/Outdoor Remote Alarm Light & Horn Unit for LBW-50 or LBW-420 Ammonia Leak Detector. Provides a brighter light via a combination of long-life LEDs and a daybright lens. NEMA 4X box, light, horn, 24VDC. Output is 99db at 1 meter.

Configure

$541.20 
HO-REM-HU-ST-24
(3696)

COOL AIR  HO-REM-HU-ST-24

Cool Air High Output Remote Alarm Horn & Strobe Unit for LBW-50 or LBW-420 Ammonia Leak Detector. NEMA 4X box. Max 117 dB(A), No Cable.

Configure

$582.20 
DCSAP-08
(915)

COOL AIR  DCSAP-08

Cool Air 8 Channel (Zone) Digital Central Supervisory Alarm Panel for single-location monitoring of remote Ammonia (NH3) leak detectors. Designed to monitor up to 32 Ammonia Leak Detectos. Audible and visible warnings. NEMA 4X Enclosure. Optional 16, 24 and 32 channels.

Configure

$2,788.00 
> AMMONIA :    42 Items found.
GDS-IR2-1-301-0
(5829)

GDS  GDS-IR2-1-301-0

GDS GDS-IR2 Infrared Stainless Steel Sensor Head for detection of Ammonia (NH3) in Harsh Enviroments. 3-Wire output 4-20 mA transmitter. CSA certified for use in Class 1 Division 1.

QTU-QRU-C-2111
(6984)

SPECTREX  QTU-QRU-C-2111

SPECTREX SafEye Quasar 960 open path gas detector and source with ultraviolet technology to detect toxic Ammonia (NH3) at very low concentrations. Long range and high speed response. 24 Vdc. 0-20 mA, HART and RS-485 Modbus outputs. Stainless steel housing. IP66 and IP68. NEMA 250 6P. FM, ATEX, IECEx, CSA and SIL2 approvals.

Configure

$27,342.56 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.