Cool Air Lbw-50-rlv | Ammonia | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

COOL AIR   LBW-50-RLV

COOL AIR LBW-50-RLV
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Cool Air Ammonia Relief Line Vent Gas Detector LBW-RLV for continuos monitoring of Ammonia (NH3) 25-800ppm refrigeration gas emergency vent line headers. NEMA 4 weatherproof enclosure. 2 Alarm and 1 Auxiliary relays, 2 wires for power. 4 wires for control signals. 100 to 240VAC, 50/60 Hz, 16 VAC, or 24 VDC UL Listed
Includes TB-100 test bottle

LBW-50-RLV   
1,332.50

Backup Battery
Remote Sensor
Alarm
Washdown Utility Tube

 In Stock  ]

Housed in a durable, weatherproof enclosure (NEMA 4 rated), the Ammonia Relief Line Gas Detector provides reliable detection of refrigeration system overpressure or relief valve leakage.

The unit contains a voltage stabilized amplifier circuit which enables detection of ammonia gas in the ammonia emergency relief line. Sensor trip point is adjustable from 25 ppm to 800 ppm.

18 gauge, 6 conductor wire, 2 wires for power and 4 wires for control signals. Available in 115/230 VAC, 50/60 Hz, or 16 VAC if you use the Central Supervisory Control Panel. Connect all wires to factory wired terminal strip.

Features
  • NO SENSOR DEPLETION during an ammonia leak, from background ammonia vapors, or during testing &/or calibration.
  • Affordable
  • Dependable
  • One year warranty
  • Rugged, weatherproof enclosure (NEMA 4)
  • High quality, UL listed components
  • Virtually maintenance free
  • Can be tied into existing security alarm system
  • Easy to adjust calibration
  • Sensitivity adjustable from 25 ppm to 800 ppm
Warranty

12 months warranty on workmanship from date of sale. Cool Air Incorporated reserves the right to make changes in the design of this unit without notification.

Coolair Relief Line Gas Detector Diagram
Coolair Relief Line Gas Detector Diagram

GENERAL SPECIFICATIONS
Size4-1/8"H x 6-7/8"W x 5-1/4"D.
Weight 4 lbs.
Power input115/230 VAC, 50/60 Hz, or 16 VAC.
Sensitivityas determined by trip point settings at remote detectors, adjustable from 25 ppm to 800 ppm concentration of NH3. Early warning alarm trip point at remote detectors is set at 25 ppm (not adjustable).
High and Low Temperature Set Point Range-50°F to 50°F (No heater required)
General AccuracyDependent on the calibration solution which is typically +/- 5%
Linearity+/-1% of full scale. Full scale being defined as the calibrated solution concentration
Sensor Life Span 10 Years plus. Sensor operation and life span are not affected by background NH3 gas
Agency ApprovalsTUV Rheinland USA/CANADA (tested to UL 61010-1:2004 R7.05; CAN/CSA-C22.2 61010-1:2004)
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    10 Items found.
(6213)

COOL AIR  EC-CAL-ADPT

Cool Air calibration cup adaptor for COOL Air Ammonia Electrochemical sensors, to be used with 0.3 LPM flow regulator.



$21.75 
TB-100
(919)

COOL AIR  TB-100

Cool Air Replacement Test Bottle for LBW-50 or LBW-420 Ammonia Leak Detectors, 100 ppm NH3.



$45.50 
LBW-BB
(1559)

COOL AIR  LBW-BB

Backup Batery for Cool Air LBW-50, LBW-RLV, OR LBW-420



$63.70 
NH3-S-RPL
(4456)

COOL AIR  NH3-S-RPL

Cool Air Replacement Solid State Ammonia Sensor for LBW-50, LBW-420, Watchman and RLV Ammonia Leak Detectors.



$122.85 
LBW-420-RS-050
(913)

COOL AIR  LBW-420-RS-050

Cool Air Remote Sensor for LBW-420 Ammonia Leak Detector. Comes with NEMA 4X box, circuit board with sensor socket and 50 feet of cable.

Configure

$262.40 
NH3-50-EC
(6211)

COOL AIR  NH3-50-EC

Cool Air Replacement Electrochemical Ammonia Sensor for LBW-50 Ammonia Leak Detectors.



$282.90 
DM-LCD
(3697)

COOL AIR  DM-LCD

Cool Air LCD door monitor remote display for PPM ammonia concentration from a single LBW-420/420-1 Detector. 4-20 mA output. 24 VDC.

Configure

$360.80 
REM-1L-R-FLASH
(5115)

COOL AIR  REM-1L-R-FLASH

Cool Air Indoor/Outdoor Remote Alarm Light & Horn Unit for LBW-50 or LBW-420 Ammonia Leak Detector. Provides a brighter light via a combination of long-life LEDs and a daybright lens. NEMA 4X box, light, horn, 24VDC. Output is 99db at 1 meter.

Configure

$541.20 
HO-REM-HU-ST-24
(3696)

COOL AIR  HO-REM-HU-ST-24

Cool Air High Output Remote Alarm Horn & Strobe Unit for LBW-50 or LBW-420 Ammonia Leak Detector. NEMA 4X box. Max 117 dB(A), No Cable.

Configure

$582.20 
DCSAP-08
(915)

COOL AIR  DCSAP-08

Cool Air 8 Channel (Zone) Digital Central Supervisory Alarm Panel for single-location monitoring of remote Ammonia (NH3) leak detectors. Designed to monitor up to 32 Ammonia Leak Detectos. Audible and visible warnings. NEMA 4X Enclosure. Optional 16, 24 and 32 channels.

Configure

$2,788.00 
> AMMONIA :    42 Items found.
ECFX-200-N
(6467)

HONEYWELL  ECFX-200-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-200 with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,596.46 
LBW-420-1-SS
(912)

COOL AIR  LBW-420-1-SS

Cool Air LBW-420 Ammonia (NH3) 0-100/1000ppm Gas Leak Detector 4-20mA analog output. NEMA 4X enclosure. Alarm, pre-alarm and auxiliary relays. 115/230 VAC, 50/60 Hz, or 24 VDC. User Adjustable ranges: 0-100, 0-250, 0-500 and 0-1000ppm

Configure

$1,631.80 
ECFX-1000-N
(6587)

HONEYWELL  ECFX-1000-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-1000 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,654.94 
LBW-420-LEL-DC-01
(6055)

COOL AIR  LBW-420-LEL-DC-01

Cool Air LBW-420-LEL Ammonia (NH3) 0-9.9% Gas Leak Detector. Includes 4-20mA analog output, 3 latching relays and LED Display. 18-36 VDC (Optional AC). NEMA 4X and UL listed enclosure.

Configure

$1,676.90 
ECFX-500-N
(6468)

HONEYWELL  ECFX-500-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-500 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

GG-NH3-2-EXP
(4149)

CALIBRATION TECHNOLOGIES  GG-NH3-2-EXP

CTI GasGuard NH3-2%-EXP Ammonia Catalytic Bead Sensor 0-2% (up to 20000 ppm) for gas leak detection in compressorrooms where E-stop or electrical shunt trip is desired. Explosion-proof. Enclosure and sensor head certified for hazardous locations. Industry standard linear 4-20 mA output. Power: 24 VDC, 120 mA. NEC, UL, CSA, FM and IEC Approvals.

Configure

$1,786.74 
2100AL-0-9012/0300P/L0
(132)

RC SYSTEMS  2100AL-0-9012/0300P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,789.61 
LBW-HHS-II
(1556)

COOL AIR  LBW-HHS-II

Cool Air LBW-HHS-II Portable Handheld Ammonia (NH3) Leak Detector. Glass Filled Polycarbonate Housing. Includes touch-sensitive LCD display, 3 concentration alarms (caution, warning and danger), USB output, RS-232 Output Cable, 4GB of internal memory and rechargeable NiMH battery.

Configure

$1,820.40 
VL-F7-NH3-N4-LPA-NO
(3720)

HONEYWELL  VL-F7-NH3-N4-LPA-NO

Honeywell Analytics Manning Vent Line (VL) leak detector for Ammonia (NH3) 0-10000ppm (1%). Continuos monitoring. Can be connected to and monitored by all Honeywell Analytics readouts. 2” cast steel “T”. 4-20mA output. NEMA 4 Enclosure. Linear pre-amp.



 
S3KUL2-XNXXSA1SS
(685)

HONEYWELL  S3KUL2-XNXXSA1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring AMMONIA (NH3) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display. Optional ranges: 0-200ppm, 0-1000ppm. Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,837.05 
961-500026-100G
(6349)

DETCON  961-500026-100G

Detcon DM-102-NH3 Electrochemical Ammonia (NH3) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

ECFX-250-N
(6588)

HONEYWELL  ECFX-250-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-250 with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,898.10 
ECFX-100-N
(1516)

HONEYWELL  ECFX-100-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-100 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,898.10 
SPXCDULNA2
(1897)

HONEYWELL  SPXCDULNA2

Honeywell Sensepoint XCD RTD Gas Detector for Ammonia (NH3) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 50 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,920.63 
31001AL-0-9012/0300P/L0
(6888)

RC SYSTEMS  31001AL-0-9012/0300P/L0

RC Systems SenSmart 3100 3 wire gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,967.53 
967-505090-100
(6070)

DETCON  967-505090-100

Detcon DM-702-NH3 Electrochemical Smart Ammonia (NH3) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

VL-F7-NH3-N4-LPA-MK
(3716)

HONEYWELL  VL-F7-NH3-N4-LPA-MK

Honeywell Analytics Manning Vent Line (VL) leak detector for Ammonia (NH3) 0-10000ppm (1%). continuous monitoring. Can be connected to and monitored by all Honeywell Analytics readouts. 2" cast steel T. 4-20mA output. NEMA 4 Enclosure. Linear pre-amp. Includes mounting kit



 
XNXUTAENNNNN-XNXXSA1SS
(835)

HONEYWELL  XNXUTAENNNNN-XNXXSA1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Ammonia (NH3) compatible with all Honeywell gas sensing technologies, with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-200ppm, 0-1000ppm

Configure

$2,251.86 
IR-F9-NH3-0/2-N1
(1548)

HONEYWELL  IR-F9-NH3-0/2-N1

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Ammonia (NH3) 0-20000 ppm with 4-20 mA output, 24VDC Power, NEMA-1 enclosure.

6100AL1-0-1015/0100P
(7001)

RC SYSTEMS  6100AL1-0-1015/0100P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Ammonia (NH3) 0-100 to 0-1000ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class I Div 2 (Non-Incendive). IP66.

Configure

$2,389.61 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.