Prosense Pc3-4824 | Ammonia | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

PROSENSE   PC3-4824

PROSENSE PC3-4824
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Prosense PC3-4824 Gas Detector with Electrochemical sensor for Ammonia (NH3) with range 0-100 ppm or 0-1000 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

PC3-4824   
823.68

Range
Relays

   3 Weeks  ]
Epoxy painted aluminum housing

PC3 has a certain higher price-performance ratio considering its substitutes in the market.

Well-Suited Solution for Light Indusrty

PC3 is specially designed for the light industry as a Category 3 device.

Accurate Readings

Electrochemical, and Catalytic sensors undoubtedly provide an accurate and sensitive measurement.

Ready to Operate

4-20mA Analog is provided onboard to operate properly without any additional setup. Additionally, it can be integrated into other systems with Modbus RS485 RTU and relay module.

Automatic Calibration

Detector calibration can be done automatically via preset values recorded in detector software once calibration requirements are provided.

Fail-Safe Technology Alarming

Alarm 1 and Alarm 2 relays are easy to set to default LEL, ppm, VOL levels. The fault relay output properly indicates fault status.

Robust and Reliable Housing

Epoxy painted aluminum housing and IP65 protection class allow to use in harsh environmental conditions.

Universal Outputs

4-20mA Analog, Modbus RS485 RTU, and relay outputs are simple to operate efficiently and they are universally usable in any control panel.

Applications
  • Process Industry
  • Chemical Industry
  • Food and Medicine Facilities
  • Gas Distribution Stations
  • Laboratories
Optional Modules

P-3R+: 2 Alarms and 1 Fault (NO/NC adjustable) relay output card.

Specifications PC3-XY24
Sensing Element Electrochemical
Output Signal 4-20mA Analog
Modbus RS485 RTU
Sensor Warm-Up Time <30*sec
Accuracy %±1
Operating Temperature ‐20°C ~ +50°C
Humidity 5 ~ 95%RH Non-Condensing
Input Voltage Min 10VDC - Max 32VDC - Nominal 24VDC
Power Consumption Max. 2W
Optional Relay Outputs 2 Alarms (Selectable) and 1 Fault (All relays are NO/NC adjustable)
Cable Entry 1x 1/2"NPT
Ingress Protection IP65
Enclosure Epoxy Painted Die-Cast Aluminum
Sensor Head Nickel‐Plated Brass SH20
Dimensions 230x120x100mm
Weight 1100gr
Hazardous Class Zone 2 ‐ Category 3
Standards IEC EN 60079-0
IEC EN 60079-1
IEC EN 60079-18
Warranty 12 months from date of shipment from Prosense Technology
Export Info
Made inTurkey
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    17 Items found.
PR-KT12
(6978)

PROSENSE  PR-KT12

Prosense 1/2" NPT ATEX Certified Blind Plug for P, PQ and B Series gas detectors



$12.28 
PR-NYY12
(6976)

PROSENSE  PR-NYY12

Prosense 1/2"NPT ATEX Certified Cable Gland for P, PQ and B Series gas detectors



$18.41 
PROX-EDU
(7017)

PROSENSE  PROX-EDU

Prosense PDM Software 1-Year license for maintenance, setup, calibration, monitoring and troubleshooting of PQ, P, PC3 series gas detectors. Calibration function is licensed separately, to print calibration reports or certificates directly from the program after calibration.

Configure

$165.00 
SP-PC3-TB02
(7038)

PROSENSE  SP-PC3-TB02

Prosense PC3 Transmitter/Main Board for PC3 series gas detectors



$165.00 
MANNING-10566-L9-EQUIV
(4653)

PORTAGAS  MANNING-10566-L9-EQUIV

Calibration Gas Ammonia (NH3) 50ppm. Balance Air. Size 34 Liter GAL. C-10 Inlet (Made by Portagas)

Configure

$178.53 
BW-CG2A5034-EQUIV
(2142)

PORTAGAS  BW-CG2A5034-EQUIV

Calibration Gas Ammonia 50ppm Balance Air Size 34 Liter GAL C-10 Inlet Cylinder (Made by Portagas)

Configure

$178.53 
MSA-10011937-EQUIV
(2952)

PORTAGAS  MSA-10011937-EQUIV

Calibration Gas Ammonia 50ppm Balance Nitrogen Size 34 Liter GAL C-10 Inlet Cylinder (Made by Portagas) (No RFID neck ring)

Configure

$178.53 
CYL-10005475
(1266)

PORTAGAS  CYL-10005475

Calibration Gas Ammonia (NH3) 50 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$252.43 
BW-CG2A5058-EQUIV
(2143)

PORTAGAS  BW-CG2A5058-EQUIV

Calibration Gas Ammonia 50ppm Balance Nitrogen Size 58 Liter GAL C-10 Inlet Cylinder (Made by Portagas)

Configure

$252.43 
CYL-10005003
(297)

PORTAGAS  CYL-10005003

Calibration Gas Ammonia (NH3) 50 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$252.43 
RAE-600-0058-000-EQUIV
(2632)

PORTAGAS  RAE-600-0058-000-EQUIV

Calibration Gas Ammonia 50ppm Balance Nitrogen 58 Liter GAL Cylinder (Made by Portagas)

Configure

$252.43 
SCOTT-077-0207-EQUIV
(2430)

PORTAGAS  SCOTT-077-0207-EQUIV

Calibration Gas Ammonia 500ppm Balance Nitrogen Size 58 Liter GAL C-10 Inlet Cylinder (Made by Portagas)

Configure

$252.43 
P-ASU-2
(6989)

PROSENSE  P-ASU-2

Prosense flow adapter cell for SH30 and SH20 sensor heads used in PQ, P, PE and PC3 series, gas sampling applications. For 6mm OD Tubing made of corrosion-resistant Teflon.



$405.90 
S-DP4
(6764)

PROSENSE  S-DP4

Prosense S-DP4 Gas Detector Controller, Alarm Panel for Up to 4 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

$772.20 
S-DP8
(6765)

PROSENSE  S-DP8

Prosense S-DP8 Gas Detector Controller, Alarm Panel for Up to 8 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

$900.90 
S-DPX064
(7034)

PROSENSE  S-DPX064

Prosense S-DPX064 Gas Detector Controller, Alarm Panel for 64 x RS485 MODBUS RTU Detectors + 8 x 4-20mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

$1,801.80 
S-DPX128
(7035)

PROSENSE  S-DPX128

Prosense S-DPX128 Gas Detector Controller, Alarm Panel for 128 x RS485 MODBUS RTU Detectors + 8 x 4-20mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

$2,316.60 
> AMMONIA :    42 Items found.
GDS-IR2-1-301-0
(5829)

GDS  GDS-IR2-1-301-0

GDS GDS-IR2 Infrared Stainless Steel Sensor Head for detection of Ammonia (NH3) in Harsh Enviroments. 3-Wire output 4-20 mA transmitter. CSA certified for use in Class 1 Division 1.

QTU-QRU-C-2111
(6984)

SPECTREX  QTU-QRU-C-2111

SPECTREX SafEye Quasar 960 open path gas detector and source with ultraviolet technology to detect toxic Ammonia (NH3) at very low concentrations. Long range and high speed response. 24 Vdc. 0-20 mA, HART and RS-485 Modbus outputs. Stainless steel housing. IP66 and IP68. NEMA 250 6P. FM, ATEX, IECEx, CSA and SIL2 approvals.

Configure

$27,342.56 
Page: 1 | 2 | 3 | All