E2s D2xs1ac115cn1a1g | Horns | Class I Div 2 And Class Ii Div 2 | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

E2S   D2XS1AC115CN1A1G

E2S D2XS1AC115CN1A1G
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
E2S D2xS1 Alarm Horn Sounder 116dB(A). Low current consumption and high SPL. Type 4/4X, IP66 enclosure. Suitable for all haz loc applications. 4 remotely selectable alarm stages. 64 alarm tone frequencies. UL approved for Class I Div 2 and Class II Div 2. IECEx and ATEX Approved.

D2XS1AC115CN1A1G   
Please Email us your request for quote   

Voltage
Cable Entries
Stopping plug/adaptor material
Enclosure colour
Metric Adaptor

 2 Weeks  ]
168 Variants of base SKU / 30 Shown below

The D2xS1 is a high output, 116dB(A) alarm horn sounder. Low current consumption and high SPL in a robust Type 4/4X, IP66 enclosure ensure the D2xS1 is suitable for all haz loc general signalling applications.

The corrosion proof, marine grade aluminium die cast enclosure is phosphated and powder coated providing resilience in the harshest of environments. One device, globally certified: ATEX, IECEx Zone 2 & 22; NEC/CEC CI D2 and CII D2; NEC CI Zone 2 and Zone 22; CEC Zone 2 & 22 and CII D2.

Features:
  • High output, up to 116dB(A)
  • 4 remotely selectable alarm stages/channels
  • Positive or negative line stage/channel switching (DC units)
  • Choice of 64 alarm tone frequencies
  • Automatic synchronisation on multi-sounder system
  • Continuously rated
  • Compact form factor
  • Robust corrosion proof aluminium enclosure
  • Stainless steel fixings
  • Dual cable entries
  • Duplicate cable terminations (in & out for daisy-chain installations)
  • Available with custom tone configurations and frequencies.
Approvals:
  • UL File ref: E2 30764
    ANSI/ISA 12 .12 .01 – 2013
    CSA C2 2 .2 No. 2 13-M1987
    ANSI/UL60079-0-13
    ANSI/UL60079-15-2 013
    ISA60079-31-2 009
    CAN/CSA C2 2 .2 No. 60079-0-11
    CAN/CSA C2 2 .2 No. 60079-15-12
    CAN/CSA C2 2 .2 No. 60079-31-12
  • IECEx cert: IECEx ULD 14.0004X
    Standards:
    IEC60079-0: ed. 6.0 (2 011-06)
    IEC60079-15: ed. 4.0 (2 010-01)
    IEC60031-31: ed. 2 .0 (2 013-11)
  • ATEX cert: DEMKO 14 ATEX 4786493904X
    Standards:
    EN60079-0:2 012
    EN60079-15:2 010
    EN60079-31:2 009

Tone Table

Stage 1 WAV file Frequency Description. Stage 2 Stage 3 Stage 4
T 1 1000 Continuous - PFEER Toxic Gas T 3 T 2 T 44
T 2 1200/500 @ 1Hz Sweeping - DIN / PFEER P.T.A.P. T 1 T 3 T 44
T 3 1000 @ 0.5Hz (1s on, 1s off) Intermittent - PFEER Gen. Alarm T 1 T 2 T 44
T 4 1.4KH-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s - NF C 48-265 T 44 T 24 T 1
T 5 544(100mS)/440 (400mS) - NF S 32-001 T 52 T 19 T 1
T 6 1500/500 - (0.5s on , 0.5s off) x3 + 1s gap - AS4428 T 7 T 44 T 1
T 7 500-1500Hz Sweeping 2 sec on 1 sec off - AS4428 T 6 T 44 T 1
T 8 500/1200Hz @ 0.26Hz(3.3s on, 0.5s off) - NEN 2575 T 44 T 24 T 35
T 9 1000 (1s on, 1s off)x7 + (7s on, 1s off) - IMO Code 1a T 18 T 34 T 1
T 10 1000 (1s on, 1s off)x7 + (7s on, 1s off) - IMO Code 1a T 21 T 34 T 1
T 11 420(0.5s on, 0.5s off)x3 + 1s gap - ISO 8201 Temporal T 44 T 1 T 8
T 12 1000(0.5s on, 0.5s off)x3 + 1s gap - ISO 8201 Temporal T 44 T 1 T 8
T 13 422/775 - (0.85 on, 0.5 off) x3 + 1s gap - NFPA Temporal T 44 T 1 T 8
T 14 1000/2000 @ 1Hz - Singapore T 23 T 3 T 35
T 15 300 Continuous T 44 T 24 T 35
T 16 440 Continuous T 44 T 24 T 35
T 17 470 Continuous T 44 T 24 T 35
T 18 500 Continuous - IMO code 2 (Low) T 44 T 24 T 35
T 19 554 Continuous T 64 T 24 T 35
T 20 660 Continuous T 44 T 24 T 35
T 21 800 Continuous - IMO code 2 (High) T 44 T 24 T 35
T 22 1200 Continuous T 44 T 24 T 35
T 23 2000 Continuous T 15 T 3 T 35
T 24 2400 Continuous T 48 T 20 T 35
T 25 440 @ 0.83Hz (0.60s on, 0.60s off) Intermittent T 1 T 44 T 8
T 26 470 @ 0.9Hz (0.55s on, 0.55s off) Intermittent T 1 T 44 T 8
T 27 470 @ 5Hz (0.10s on, 0.10s off) Intermittent T 1 T 44 T 8
T 28 544 @ 1.14Hz (0.43s on, 0.44s off) Intermittent T 44 T 24 T 8
T 29 655 @ 0.875Hz (0.57s on, 0.57s off) Intermittent T 1 T 44 T 8
T 30 660 @ 0.28Hz (1.80s on, 1.80s off) Intermittent T 44 T 24 T 8
T 31 660 @ 3.3Hz (0.15s on, 0.15s off) Intermittent T 30 T 24 T 8
T 32 745 @ 1Hz (0.50s on, 0.50s off) Intermittent T 44 T 24 T 8
T 33 800 (0.25s on, 1.00s off) Intermittent T 53 T 24 T 8
T 34 800 @ 2Hz (0.25s on, 0.25s off) - IMO code 3.a (High) T 56 T 24 T 8
T 35 1000 @ 1Hz (0.50s on, 0.50s off) Intermittent T 44 T 24 T 8
T 36 2400 @ 1Hz (0.50s on, 0.50s off) Intermittent T 21 T 24 T 8
T 37 2900 @ 5Hz (0.10s on, 0.10s off) Intermittent T 53 T 24 T 8
T 38 363/518 @ 1Hz (0.50s / 0.50s) Alternating T 1 T 8 T 19
T 39 450/500 @ 2Hz (0.25s / 0.25s) Alternating T 1 T 8 T 19
T 40 554/440 @ 1Hz (0.50s / 0.50s) Alternating T 44 T 24 T 19
T 41 554/440 @ 0.65Hz (0.76s / 0.76s) Alternating T 1 T 8 T 19
T 42 561/760 @ 0.83Hz (0.60s / 0.60s) Alternating T 1 T 8 T 19
T 43 780/600 @ 0.96Hz (0.52s / 0.52s) Alternating T 1 T 8 T 19
T 44 800/1000 @ 2Hz (0.25s / 0.25s) Alternating T 5 T 24 T 19
T 45 970/800 @ 2Hz (0.25s / 0.25s) Alternating T 1 T 8 T 19
T 46 800/1000 @ 0.875Hz (0.57s / 0.57s) Alternating T 53 T 24 T 19
T 47 2400/2900 @ 2Hz (0.25s / 0.25s) Alternating T 57 T 24 T 19
T 48 500/1200 @ 0.3Hz (1.67s / 1.67s) Sweeping T 44 T 24 T 12
T 49 560/1055 @ 0.18Hz (2.73s / 2.73s) Sweeping T 44 T 24 T 12
T 50 560/1055 @ 3.3Hz (0.15s / 0.15s) Sweeping T 44 T 24 T 12
T 51 600/1250 @ 0.125Hz (4s / 4s) Sweeping T 44 T 24 T 12
T 52 660/1200 @ 1Hz (0.50s / 0.50s) Sweeping T 64 T 24 T 12
T 53 800/1000 @ 1Hz (0.50s / 0.50s) Sweeping T 56 T 24 T 12
T 54 800/1000 @ 7Hz (0.07s / 0.07s) Sweeping T 57 T 24 T 12
T 55 800/1000 @ 50Hz (0.01s / 0.01s) Sweeping T 54 T 24 T 12
T 56 2400/2900 @ 7Hz (0.07s / 0.07s) Sweeping T 57 T 24 T 12
T 57 2400/2900 @ 1Hz (0.50s / 0.50s) Sweeping T 47 T 24 T 12
T 58 2400/2900 @ 50Hz (0.01s / 0.01s) Sweeping T 54 T 24 T 12
T 59 2500/3000 @ 2Hz (0.25s / 0.25s) Sweeping T 44 T 24 T 12
T 60 2500/3000 @ 7.7Hz (0.65s / 0.65s) Sweeping T 44 T 24 T 12
T 61 800Hz Motor Siren T 44 T 24 T 12
T 62 1200Hz Motor Siren T 44 T 24 T 12
T 63 2400Hz Motor Siren T 44 T 24 T 12
T 64 Simulated Bell T 44 T 21 T 12
Country specific or custom tone configurations and alarm frequencies are available upon request.

Specification
Maximum output: 116dB(A) @ 1 metre [107dB(A) @ 10ft/3m]
Nominal output: 112 dB(A) @ 1m +/- 3dB - Tone 2 [103dB(A) @ 10ft/3m]
No. of tones: 64 (UKO O A / PFEER compliant)
No. of stages: 4
Volume control: Adjustable -12 dB(A) [Tone 2]
Effective range: 125m/410ft @ 1KHz
Voltages DC: 24Vdc (10-30V dc);
48Vdc (38-58V dc)
Voltages AC: 115Vac 50/60Hz;
230Vac 50/60Hz
Ingress protection: EN60529: IP66
UL50E / NEMA2 50: 4 / 4X / 3R / 13
Housing material: Marine grade aluminium Al Si12 CuS
Colour: Red (RAL3000) & Grey (RAL7038)
Cable entries: 2 x M20 x 1.5mm threaded gland entries.
Terminals: 0.5 - 2.5mm2 (20-14 AWG)
Grounding stud: M5
Operating temp: -40 to +70°C [-40° to +158°F] - Class I Div 2
-40 to +50°C [-40° to +122 °F] - All other markings
Relative humidity: 90% at 20°C [68°F]
Weight: DC: 2.48kg/4.96Ibs AC:2.73kg/5.46lbs
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)85318030

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> HORNS :    73 Items found.
BEXDS110DR_12DC
(3521)

E2S  BEXDS110DR12DC

E2S BExDS110DR flameproof radial output Alarm Sounder 117dB(A). Anti-Static High impact ABS flare. LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1 & Zone 2 applications. Omni-directional signal. Two M20 cable entries. IP66/67. ATEX, IECEx & GOST-R (1ExdIICT4) Approved.

BEXS110DRDC012AB1A1R
(3519)

E2S  BEXS110DRDC012AB1A1R

E2S BExS110DR Flameproof and Explosion Proof radial output Alarm Sounder 117dB(A). High impact UL94 V0 & 5VA FR ABS flare. LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1 & Zone 2 applications. Omni-directional signal. Two M20 cable entries. IP66/67. ATEX, IECEx and INMETRO approvals.

BEXS110DFDC012AB1A1R
(3523)

E2S  BEXS110DFDC012AB1A1R

E2S BExS110 Flameproof and Explosion Proof Alarm Sounder 117dB(A). High impact UL94 V0 & 5VA FR ABS flare. LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX, IECEx, SIL 1, SIL 2 and INMETRO approvals.

BEXS110E_12DC
(3526)

E2S  BEXS110E12DC

E2S BExS110E flameproof Alarm Sounder 117dB(A). High impact UL94 V0 & 5VA FR ABS flare. LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66. ATEX, IECEx & GOST-R (2ExdeIICT4) Approved.

BEXS110ER_12DC
(3520)

E2S  BEXS110ER12DC

E2S BExS110ER flameproof radial output Alarm Sounder 117dB(A). High impact UL94 V0 & 5VA FR ABS flare. LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1 & Zone 2 applications. Omni-directional signal. Two M20 cable entries. IP66. ATEX, IECEx & GOST-R (2ExdeIICT4) Approved.

BEXTS110D115AC
(3671)

E2S  BEXTS110D115AC

E2S BExTS110D flameproof Telephone Initiated Alarm Horn 117dB(A). LM6 aluminium enclosure. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX, IECEx, GOST-R (1ExdIICT4), SIL1 and Inmetro Approved.

BEXDS110ER_12DC
(3522)

E2S  BEXDS110ER12DC

E2S BExDS110ER flameproof radial output Alarm Sounder 117dB(A). Anti-Static High impact ABS flare. LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1 & Zone 2 applications. Omni-directional signal. Two M20 cable entries. IP66. ATEX, IECEx & GOST-R (2ExdeIICT4) Approved.

BEXDS110E_12DC
(3525)

E2S  BEXDS110E12DC

E2S BExDS110E flameproof Alarm Sounder 117dB(A). Anti-Static High impact ABS flare. LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66. ATEX, IECEx & GOST-R (2ExdeIICT4) Approved.

BEXDS110D_12DC
(3524)

E2S  BEXDS110D12DC

E2S BExDS110D flameproof Alarm Sounder 117dB(A). Anti-Static High impact ABS flare. LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX, IECEx & GOST-R (1ExdIICT4) Approved.

D1xS1RDC024AB1A1R
(4409)

E2S  D1xS1RDC024AB1A1R

E2S D1xS1R 115dB(A) high output Radial Alarm Horn Sounder with an omni-directional horn. Low current consumption and high SPL. 64 alarm sounds. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

D1xS1FDC024AB1A1R
(4408)

E2S  D1xS1FDC024AB1A1R

E2S D1xS1F 117dB(A) high output Alarm Horn Sounder with re-entrant flare horn. Low current consumption and high SPL. 64 alarm sounds. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

BEXDTS110D115AC
(3672)

E2S  BEXDTS110D115AC

E2S BExDTS110D flameproof Telephone Initiated Alarm Horn 117dB(A). LM6 aluminium enclosure. Suitable for Zone 1, 2, 21 & 22 applications. Two M20 cable entries. IP66/67. ATEX, IECEx, GOST-R (1ExdIICT4), SIL1 and Inmetro Approved.

BEXH120D_24DC-G
(3661)

E2S  BEXH120D24DC-G

E2S BExH120D flameproof 'Hootronic' Alarm Horn 117.5dB(A). LM6 aluminium enclosure. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX, IECEx, SIL1, Inmetro and GOST-R Approved.

BEXDH120DR24DC-R
(4404)

E2S  BEXDH120DR24DC-R

E2S BExDH120-R flameproof 'Belltronic' Alarm Horn 106dB(A). LM6 aluminium enclosure. Suitable for Zone 1, 2, 21 & 22 applications. Two M20 cable entries. Anti-Static High impact ABS flare. IP66/67. 24VDC. Red. ATEX and IECEx, SIL1, Inmetro and GOST-R Approved.

BEXDH120D_24DC-G
(3662)

E2S  BEXDH120D24DC-G

E2S BExDH120D flameproof 'Hootronic' Alarm Horn 117.5dB(A). LM6 aluminium enclosure. Suitable for Zone 1, 2, 21 & 22 applications. Two M20 cable entries. IP66/67. ATEX, IECEx, SIL1, Inmetro and GOST-R Approved.

D1xS2FDC024AB1A1R
(4410)

E2S  D1xS2FDC024AB1A1R

E2S D1xS2F 125dB(A) high output Alarm Horn Sounder with re-entrant flare horn. Low current consumption and high SPL. 64 alarm sounds. Type 4/4x, IP66 aluminium enclosure. Suitable for all Class I & II Division 1, Zone 1 & 20 applications. UL and CSA Approved.

DB3BWN0481BNNNNN
(4230)

MEDC  DB3BWN0481BNNNNN

MEDC DB3B Sounder (up to 125dB(A)) with 28 output tones. Weatherproof only version. IP66 & IP67. NEMA 4X & 6. Designed to be used on potentially explosive gas and dust atmospheres. -55C to +70C.

Configure

$1,124.54 
BEXDS120D_12DC
(3659)

E2S  BEXDS120D12DC

E2S BExDS120D flameproof Alarm Horn Sounder 123dB(A). LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1, 2, 21 & 22 applications. Two M20 cable entries. IP66/67. ATEX, IECEx, GOST-R (1ExdIICT4), VdS, CPD, SIL1 and Inmetro Approved.

BEXS120DFDC012AB1A1R
(3657)

E2S  BEXS120DFDC012AB1A1R

E2S BExS120 Flameproof and Explosion Proof Alarm Horn Sounder 123dB(A). LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66/67. ATEX, IECEx, VdS, CPD, SIL1 and INMETRO approvals.

BEXS120E_12DC
(3658)

E2S  BEXS120E12DC

E2S BExS120E flameproof Alarm Horn Sounder 123dB(A). LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1 & Zone 2 applications. Two M20 cable entries. IP66. ATEX, IECEx, GOST-R (2ExdeIICT4), VdS, CPD, SIL1 and Inmetro Approved.

Page: 1 | 2 | 3 | 4 | All
Cookie Notice