| Certification and Specification | 
	| ATEX Ex d Gas:	 | 
	Cert. no. Baseefa13ATEX0229X. Certified to: EN60079-0,1. 
Ex II 2G, Ex d IIC T4/T5/T6 Gb | 
	| ATEX Ex d Gas & Dust: | 
	Cert. no. Baseefa13ATEX0231X. Certified to: EN60079-0,1,31. 
Ex II 2GD, Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66. | 
	| ATEX Ex de Gas: | 
	Cert. no. Baseefa13ATEX0232X. Certified to: EN60079-0,1,7. 
Ex II 2G, Ex de IIC T4/T5/T6 Gb. | 
	| ATEX Ex de Gas & Dust: | 
	Cert. no. Baseefa13ATEX0233X. Certified to: EN60079-0,1,7,31. 
Ex II 2GD, Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66. | 
	| IECEx Ex d Gas: | 
	Cert. no. IECEx BAS 13.0112X. Certified to: IEC60079-0,1. 
Ex d IIC T4/T5/T6 Gb. | 
	| IECEx Ex d Gas & Dust: | 
	Cert. no. IECEx BAS 13.0113X. Certified to: IEC60079-0,1,31. 
Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66. | 
	| IECEx Ex de Gas: | 
	Cert. no. IECEx BAS 13.0114X. Certified to: IEC60079-0,1,7. 
Ex de IIC T4/T5/T6 Gb. | 
	| IECEx Ex de Gas & Dust: | 
	Cert. no. IECEx BAS 13.0115X. Certified to: EN60079-0,1,7,31. 
Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66. | 
	| UL Haz Locs: | 
	UL Listed for USA and Canada, fire alarm or general use, listing no. E203310. 
Class I, Div 2. Groups A-D. Class I, Zone 1, Ex d IIC / AEx d IIC Gb 
Class II, Div 2. Groups F&G. Zone 21 AEx tb IIIC. 
Class III Div 1. | 
	| UL Ord Locs: | 
	UL Listed for USA and Canada, fire alarm or general use, listing no. S8116. | 
	| CUTR Ex d Gas:	 | 
	1Ex d IIC T4/T5/T6 Gb. | 
	| CUTR Ex d Gas & Dust:	 | 
	1Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db. | 
	| CUTR Ex de Gas: | 
	1Ex de IIC T4/T5/T6 Gb. | 
	| CUTR Ex de Gas & Dust: | 
	1Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db. | 
	| Russian Fire Approval: | 
	All CUTR certified units are Russian Fire Approved. | 
	| CQST Ex d Gas: | 
	Ex d IIC T4/T5/T6 Gb. | 
	| CQST Ex d Gas & Dust: | 
	Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db. | 
	| Inmetro Ex d Gas: | 
	Ex d IIC T4/T5/T6 Gb. | 
	| Inmetro Ex d Gas & Dust: | 
	Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66. | 
	| Inmetro Ex de Gas: | 
	Ex de IIC T4/T5/T6 Gb. | 
	| Inmetro Ex de Gas & Dust: | 
	Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db IP66. | 
	| Material | 
	Ex enclosure - Flame retardant, UV stable, Glass reinforced polyester. Flare - Flame retardant, high impact, UV stable, thermoplastic polyester. (UV stability tested to ISO 4892 part 3). Hardware - Bracket, fixings and captive cover screws in 316 stainless steel. | 
	| Fire retardancy: 	 | 
	Body - Glass reinforced polyester. V0 flammability rating. Outer Flare - Thermoplastic Polyester. V0 flammability rating. | 
  | Finish: | 
  Body - natural black. Flare - natural black, natural red or painted as specified.	(Black short flare painted black). | 
  | Voltage: | 
  DC: 12 - 48V AC: Up to 254V. If using an EOL resistor with a value between 700Ω and 2KΩ the maximum voltage must be limited to 28.8Vdc, if using an EOL resistor with a value between 470Ω and 700Ω the maximum voltage should be limited to 26Vdc. | 
	| Weight: | 
	Ex d/UL - 4.6kg, Ex de - 5.4kg. Based on long flare DC unit. | 
	| Ingress Protection: | 
	IP66 & IP67, NEMA 4X & 6. (IPx7 & NEMA 6 on terminal chamber only). | 
	| Earth Continuity: | 
	Optional for Ex de version. Not available on Ex d unit. | 
	| Entries: | 
	Up to 2 x M20 or 1 / 2 ” NPT. Blanking plug available. | 
	| Terminals:  | 
	AC: 7 x 2.5mm2 (4 for loop in/out power, 3 for tone selection) (Standard unit only). DC: 8 x 2.5mm2 (8 for loop in/out power and tone selection) (Standard unit only). | 
  | Mounting arrangement: | 
  Stainless steel bracket with ratchet facility, optional swivel bracket available. | 
  | Labels: | 
  Optional duty and tag labels available. | 
  | Tone information: | 
  28 tones per stage. Additional custom tones available (Contact MEDC) Suitable for use with 200Hz tones. |