E2s Stexcp8pbsasdn1a1r | Call Points | Zone 1 And Zone 2 | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

E2S   STEXCP8PBSASDN1A1R

E2S STEXCP8PBSASDN1A1R
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
E2S STExCP8-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1 & 2. 316L stainless steel enclosure. 24VDC, 48VDC or 250VAC. 3 M20 entries. Single or double switch. IP66. ATEX, IECEx and SIL 2 certified.

STEXCP8PBSASDN1A1R   
Please Email us your request for quote   

Switch type
Cable Entries
Terminals
Lift flap:
Duty Label
Housing Color
E.O.L. Resistor
Series Resistor
Metric Adaptor

   2 Weeks  ]
251 Variants of base SKU / 30 Shown below

The STExCP8-PB latching, dual action push button manual call point, featuring 316L stainless steel enclosures, is designed for the harshest of environments.

Approved for Zone 1 and 2 hazardous areas for fire and gas alarm systems plus emergency shutdown and process control applications. Available with standard DIN rail terminals or the innovative E2S termination board providing dedicated connections for field installed EOL and/or series devices. SIL 2 compliant to IEC 61508 (2010). DNV type approved for exposed locations.

Features
  • Robust corrosion proof 316L stainless steel enclosure
  • Epoxy powder coat paint finish
  • Alternative housing colours are available to meet specific
  • requirements
  • Ingress protection IP66
  • Single or double switch
  • Optional equipment tags and duty labels
  • 2 × 316 Stainless steel stopping plugs included
  • 3 x M20 cable entries
  • Stainless steel fasteners
  • DNV type approved IEC 60945 & DNVGL-CG-0339
Approvals:

  • IECEx certificate: IECEx ULD 15.0018X,
    IEC 60079-0:2011 Edition: 6.0,
    IEC 60079-1:2014-06 Edition: 7.0
  • ATEX certificate: DEMKO 15 ATEX 1589X,
    EN 60079-0:2012+A11:2013
    EN 60079-1:2014
  • TR-CU Ex EAC certificate: RU C-GB.AA71.B.00109
  • SIL 2 compliant to IEC 61508 (2010)
Coding
  • Ex db IIC T6 Gb Ta. -55°C to +70°C (Single switch)
  • Ex db IIC T5 Gb Ta. -55°C to +70°C (Dual switch)
  • Ex db IIC T6 Gb Ta. -55°C to +60°C (Dual switch)

Specification
Coding: Ex db IIC T6 Gb Ta. -55°C to +70°C (Single switch)
Ex db IIC T5 Gb Ta. -55°C to +70°C (Dual switch)
Ex db IIC T6 Gb Ta. -55°C to +60°C (Dual switch)
Ingress protection: EN/IEC 60529 – IP66
Enclosure matl: 316L Stainless Steel
Colour: RAL3000 Red (others available on request)
Cable entries: 2 x M20x1.5 top and 1 x M20x1.5 side.
Back box can be rotated to give 2 x bottom and 1 x side entries
Stopping plugs: 2 × 316 Stainless Steel plugs as standard
Brass and Nickel plated plugs optional
Terminals: DIN rail 8 × 2.5mm2 SAK2.5 or Termination board featuring 6 × 2.5mm2 terminals plus 4 x dedicated EOL & Series terminals
Earth: External M5 earth connection
Weight: 4.6Kg/10.14Ibs
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)8531909000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> CALL POINTS :    47 Items found.
BExCP3B-PB-ST-NL-06
(5137)

E2S  BExCP3B-PB-ST-NL-06

E2S BExCP3B-PB Push Button Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. B type (choice of end of line devices). LM6 aluminium enclosure. 470R 24Vdc. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3B-PT-ST-NL-RD-06
(5138)

E2S  BExCP3B-PT-ST-NL-RD-06

E2S BExCP3B-PT Push Button Manual Call Point (Tool resettable) for alarm systems in Zones 1, 2, 21 & 22. B type (choose of end of line devices). LM6 aluminium enclosure. 470R 24Vdc. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BGWNNNNN100DSNNN7R
(4159)

MEDC  BGWNNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Weatherproof and dust proof only (Uncertified). IP66 & IP67. Designed for use in hazardous locations and harsh environmental conditions.

Configure

$477.46 
BGIBNNNN100DSNNN7R
(4157)

MEDC  BGIBNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exia (Intrinsically Safe). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 1GD. GOST R, CQST and Inmetro approvals also available.

Configure

$494.64 
GNEXCP6B-PB-SNSNRD06
(6444)

E2S  GNEXCP6B-PB-SNSNRD06

E2S GNExCP6B-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

GNEXCP6A-PB-SNNRD
(4087)

E2S  GNEXCP6A-PB-SNNRD

E2S GNExCP6A-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

GNEXCP6B-PT-SNSNRD06
(6445)

E2S  GNEXCP6B-PT-SNSNRD06

E2S GNExCP6B-PT Tool Reset Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

GNEXCP6A-PT-SNNRD
(4088)

E2S  GNEXCP6A-PT-SNNRD

E2S GNExCP6A-PT Push Button Manual Call Point (Tool resettable) for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

PBUWNNNN0DSNNN7R
(4212)

MEDC  PBUWNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof only version. Designed for use in hazardous locations and harsh environmental conditions.

Configure

$541.92 
PBIBNNNN0DSNNN7R
(4209)

MEDC  PBIBNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 1GD, Ex ia IIC T4 Ga, Ex ia IIIC T135C Da. CUTR, Inmetro and CQST certifications also available.

Configure

$559.15 
BGEBNNNN100DSNNN7R
(1573)

MEDC  BGEBNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exed (Increased Safety). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2G. GOST R, CQST and Inmetro approvals also available.

Configure

$615.05 
BGULNNNN100DSNNN6R
(4158)

MEDC  BGULNNNN100DSNNN6R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected. Designed for use in hazardous locations and harsh environmental conditions. NEMA 4X and 6. UL approved for Class I, Div 2 and Class II, Div 2 Groups A, B, C and D. Weatherproof only version (for Ordinary Locations) also available.

Configure

$670.91 
PBULNNNN0DSNNN7R
(4211)

MEDC  PBULNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. UL Listed for Class 1, Div 2, Groups A,B,C,D, Class II, Div 2, Groups F & G.

Configure

$679.51 
PBICNNNN0DSNNF7R
(4210)

MEDC  PBICNNNN0DSNNF7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. CSA Certified, Class 1, Groups A,B,C,D

Configure

$683.83 
PBEBNNNN0DSNNN7R
(1574)

MEDC  PBEBNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2GD. EExed IIC T6 (T4 if resistors fitted). CUTR, Inmetro and CQST certifications also available.

Configure

$692.54 
D1XCP1PSDXSNNRD
(6407)

E2S  D1XCP1PSDXSNNRD

E2S D1xCP1-PS Explosion Proof Manual Alarm Pull Station for use in harsh operating environments and hazardous locations. NEMA 4X cast aluminium housing. DPDT switch. UL and FM listed.



 
XAL-53
(6225)

NOTIFIER  XAL-53

Notifier XAL-53 Explosion Proof / Weather Proof Pull Station with Ring. Copper Free Aluminum Enclosure and 3/4" NPT conduits. Suitable for Class I Div 1, Class II Div 1 & 2 and Class III on Hazardous Locations. NEMA 7. UL and CSA Approvals.



 
SM87PBLAI_NNNNNNNNNR
(4219)

MEDC  SM87PBLAINNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Intrinsically Safe (Exia), Exd, Weatherproof. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 1G, Ex ia IIC T4 Ga. CSA, CUTR, IECEx and Inmetro versions also available.

Configure

$1,230.09 
SM87PBLAULNNNNNNN_N_N_R
(4220)

MEDC  SM87PBLAULNNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Intrinsically Safe (Exia), Exd, Weatherproof. Push Button Latching Key Reset version. Designed for the most harduous environmental conditions. UL Listed: Class 1, Div 1 Groups C & D. UCL version also available.

Configure

$1,294.65 
SM87PBLAD_NNNNNNNNNR
(1575)

MEDC  SM87PBLADNNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Exd, Weatherproof. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 2 GD, Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db. CSA, CUTR, IECEx and Inmetro versions also available.

Configure

$1,346.25 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.