MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exed (Increased Safety). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2G. GOST R, CQST and Inmetro approvals also available.
Part# with Options:
BGEBNNNN100DSNNN7R
Price with Options:
574.43
Options :
Certification
EB-ATEX/CENELEC Ex ed $0.00 EG-GOST ‘R’ Ex ed $0.00 EM-Inmetro Ex ed $0.00 EQ-CQST Ex ed $0.00
(1) Certification for MEDC BGE
Entry
NN-None $0.00 1A-M16 (Entry 1 Top) $0.00 1B-M20 (Entry 1 Top) $0.00 2A-M16 (Entry 2 Top) $0.00 2B-M20 (Entry 2 Top) $0.00 3A-M16 (Entry 3 Top) $0.00 3B-M20 (Entry 3 Top) $0.00 4A-M16 (Entry 4 Bottom) $0.00 4B-M20 (Entry 4 Bottom) $0.00 5A-M16 (Entry 5 Bottom) $0.00 5B-M20 (Entry 5 Bottom) $0.00 6A-M16 (Entry 6 Bottom) $0.00 6B-M20 (Entry 6 Bottom) $0.00
(2) Conduit Entry for MEDC BG/PB
Entry
NN-None $0.00 1A-M16 (Entry 1 Top) $0.00 1B-M20 (Entry 1 Top) $0.00 2A-M16 (Entry 2 Top) $0.00 2B-M20 (Entry 2 Top) $0.00 3A-M16 (Entry 3 Top) $0.00 3B-M20 (Entry 3 Top) $0.00 4A-M16 (Entry 4 Bottom) $0.00 4B-M20 (Entry 4 Bottom) $0.00 5A-M16 (Entry 5 Bottom) $0.00 5B-M20 (Entry 5 Bottom) $0.00 6A-M16 (Entry 6 Bottom) $0.00 6B-M20 (Entry 6 Bottom) $0.00
(3) Conduit Entry for MEDC BG/PB
Label
0-None $0.00 1-Fire Break glass press here $0.00 2-Break glass press here $0.00 3-Glass label (3) specify. $0.00 4-Duty label specify. $47.65 5-Tag label specify. $47.65 7-Dot and arrows (no text) $0.00
(4) Label for MEDC BG
Label
0-None $0.00 1-Fire Break glass press here $0.00 2-Break glass press here $0.00 3-Glass label (3) specify. $0.00 4-Duty label specify. $47.65 5-Tag label specify. $47.65 7-Dot and arrows (no text) $0.00
(5) Label for MEDC BG
Label
0-None $0.00 1-Fire Break glass press here $0.00 2-Break glass press here $0.00 3-Glass label (3) specify. $0.00 4-Duty label specify. $47.65 5-Tag label specify. $47.65 7-Dot and arrows (no text) $0.00
(6) Label for MEDC BG
Voltage
A-a.c. $0.00 D-d.c $0.00
(7) Voltage for MEDC BG/PB
Switch
S-Single changeover $0.00 D-Double changeover $64.28
(8) Switch for MEDC BG
Options
N-None $0.00 P-Plastic Element (Replaces Break glass) $0.00 C-Resistor Series $63.57 D-Resistor EOL $63.57 E-Diode $63.57 S-Resistor Series & EOL $63.57 F-Earth Continuity $64.28 B-Lift Flap (BG only) $92.43 A-LED $160.68 H-Break Glass Hammer $52.32
(9) Options for MEDC BG
Options
N-None $0.00 P-Plastic Element (Replaces Break glass) $0.00 C-Resistor Series $63.57 D-Resistor EOL $63.57 E-Diode $63.57 S-Resistor Series & EOL $63.57 F-Earth Continuity $64.28 B-Lift Flap (BG only) $92.43 A-LED $160.68 H-Break Glass Hammer $52.32
(10) Options for MEDC BG
Options
N-None $0.00 P-Plastic Element (Replaces Break glass) $0.00 C-Resistor Series $63.57 D-Resistor EOL $63.57 E-Diode $63.57 S-Resistor Series & EOL $63.57 F-Earth Continuity $64.28 B-Lift Flap (BG only) $92.43 A-LED $160.68 H-Break Glass Hammer $52.32
(11) Options for MEDC BG
Terminals
6-6 x 2.5mm2 (standard) $0.00 7-7 x 2.5mm2 (standard) $0.00 9-9 x 2.5mm2 (standard) $16.12
(12) Terminals for MEDC BG
Finish
R-Red $0.00 N-Natural Black $0.00 B-Blue $47.65 Y-Yellow $47.65 G-Grey $47.65 S-Special $79.48 X-Yellow/Black Stripes $91.35
(13) Finish for MEDC BG
These manual fire alarm call points have been designed for use in
hazardous locations and harsh environmental conditions. The GRP
enclosures are suitable for use offshore or onshore, where lightweight
combined with a high level of corrosion resistance is required.
FEATURES
Polyester enclosure – light, strong and not
subject to corrosion.
2 models:
Breakglass.
Pushbutton.
4 basic versions available:
(1) Explosion protected Exe (ATEX, Chinese
[CQST],Brazilian [Inmetro])
(2) Explosion protected Exi (ATEX, GOST ‘R’,
GOST ‘K’, Chinese (CQST),
Brazilian [Inmetro] or CSA),
(3) Explosion protected: Class I, Div. 2,
Groups A-D
Class II, Div. 2, Groups F & G (PB only)
Class I, Zone 2
(4) Weatherproof & Dust-tight/UL ordinary
locations.
In line and end of line resistors and/or zener
diodes can be fitted.
Variety of colours available.
Up to 9 terminals available.
Lift flap available for extra protection against
inadvertent operation.
Optional LED – this indicates that the unit has
been operated – useful for testing purposes.
Earth continuity option for metal glands.
1 or 2 changeover switches.
Captive cover screws.
SIL 2 Certified.
Breakglass Model
No hammer required – the glass is covered by a membrane thus
protecting the operator from glass fragments.
A plastic ‘Break glass’ or deformable operating element is
available to replace the break glass*.
Once the flexible element is pressed it bends but will not break.
The unit is reset by repositioning the element. All other functions
remain the same.
Complies with the British Standard for call points.
Key operated test facility – simple but secure.
Breakglass hammer available.
Specification
Model:
BGW & PBW
*BGUL & PBUL
BGE & PBE
BGI & PBI
Protection:
Weatherproof/dust proof
Explosion Protected Class I, Div 2 Class II, Div 2
Explosion Protected Exed (Increased Safety)
Explosion Protected Exia (Intrinsically Safe)
Certification:
Weatherproof/dust proof IP66/IP67
UL Listed to Class I, Div 2, Groups A-D BGUL & PBUL Class II, Div 2, Groups F & G (PBUL only) Listing No. E186629 UL listed for ordinary locations Listing No. S8117 *Refer to UL data sheet at rear of catalogue for complete information
ATEX approved Ex II 2GD BAS02ATEX2105X (PB only) ATEX approved Ex II 2G BAS02ATEX2105X (BG only) Exed IICT6 (switch only) Exedm IICT4 (other versions) CENELEC EN50014 EN50019 EN50018 EN50028 Suitable for use in Zones 1 & 2 Chinese Certification (PBE & BGE):† CQST – Exed IIC T6 (switch only) Exedm IIC T4 (other versions) GOST ‘R’ Certification (PBE & BGE): Exedm IIC T6 Exedm IIC T4 (other versions) Russian Fire Approved Brazilian (Inmetro) Certification: BR-Ex emd IIC T4 or BR-Ex ed IIC T6 SIL 2 Certification to 61508. Cert. No. Sira 11013 (BGE only). American Bureau of Shipping Type Approval BGE only
ATEX approved Ex II 1GD Baseefa 03ATEX0084X (PB only) ATEX approved Ex II 1G Baseefa 03ATEX0084X (BG only) Exia IIC T4 CENELEC EN50014 CENELEC EN50020 Suitable for use in Zones 0, 1 & 2 CSA Certification to C22.2 (PBI only): Nos.0-M, 0.4-M, 14-M, 25, 30-M, 94, 142-M1987, 157-M1987, 157-92, Enclosure Type 4. T4A Class I Groups A, B, C & D Cert. No. 79120 GOST ‘R’ Certification (PBI & BGI): Exia IIC T4 Russian Fire Approved GOST ‘K’ Certification (PBI only): Exia IIC T4 Chinese Certification (PBI & BGI): CQST – Exia IIC T4 Brazilian (Inmetro) Certification: BR-Ex ia IIC T4 American Bureau of Shipping Type Approval
Voltage:
Up to 254V
Up to 240V
Up to 250V
Up to 28V (IS)
Certified Temp:
–40°C to +55°C Weatherproof
–25°C to +55°C (PBUL) –25°C to +55°C (BGUL) UL Version
–20°C to +50°C
ATEX/CENELEC –40°C to +70°C (PBI) ATEX/CENELEC –40°C to +50°C (BGI) CSA –50°C to +40°C (PBI only)
Switch Ratings: (1 or 2 changeover switches fitted)
d.c. - 0-30v 5A (resistive) or 3A (inductive) 30-50 1A resistive or inductive a.c. - 0-254V 5A resistive or inductive
NOT APPLICABLE
Note: UL versions Max Rating 240VAC, 3A
Specification
Material:
Anti static U.V. resistant glass reinforced polyester.
Finish:
Red painted finish as standard or to Customer specification.
British Standard for Call Points:
BS 5839 : Part 2 : 1983 (BG).
Weight:
1.2 kg. (Varies with model & entries).
Ingress Protection:
IP66 & IP67.
Entries:
Up to 4 entries, M16 or M20 top and bottom (1/2" NPT available on UL version).
Terminals:
6 x 2.5mm2 – standard (BGUL only). 7 x 2.5mm2 – standard. 9 x 2.5mm2 optional – up to 60V only.
Risistors & Diodest:
Various configurations available on versions up to 24V and all "IS" versions. (Minimum Resistor value 100ΩPBE/BGE, 470ΩPBI/BGI).
Earth Continuity:
Internal & external earth continuity is provided via an optional earth plate.
LED Indication:
A high intensity red LED can be fitted as an optional extra to indicate operation on versions up to 24V and all "IS" versions.
Labels:
BG Glass label - reads either (1) Fire Break glass – press here (2) Break glass – press her (3) Worded to customer requirements. PB & BG Duty label - worded to customer requirements. Rivetted on. PB & BG Tag label - worded to customer requirements. Screwed on.