E2s Gnexcp6b-bg-snsnnrd06 | Call Points | Zone 1 And Zone 2 | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

E2S   GNEXCP6B-BG-SNSNNRD06

E2S GNEXCP6B-BG-SNSNNRD06
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
E2S GNExCP6B-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

GNEXCP6B-BG-SNSNNRD06   
Please Email us your request for quote   

Switch type
Stopping plug material
Terminals
Lift flap:
Duty Label
Housing Color
Voltage
E.O.L. Resistor
Series Resistor
Metric Adaptor

   2 Weeks  ]
251 Variants of base SKU / 30 Shown below

The GNExCP6B manual call points are available as break glass, push button or tool reset versions. They are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems.

All types are available with EOL or series resistors, diode or Zener diodes or an LED indicator and also with either single or double pole change over switches. All versions are certified to ATEX and IECEx standards. GNExCP6C versions are certified for ambient temperatures of +55°C.

Options:
  • Alternative housing colours are available to meet specific requirements.
  • Single or double pole c/o switch.
  • DIN rail mounted terminal blocks: 8 × 2.5mm2.
  • Metalised polyester or stainless steel “Duty” label.
  • Series and/or End of Line resistors, diodes & Zener diodes
  • Indicator LED.
Approvals:

  • ATEX certificate: Sira 09ATEX3286X,
    IEC 60079-0:2007 Ed 5, EN 60079-1:2004,
    EN 60079-7:2007, IEC 60079-18:2009 Ed 3,
    EN 61241-1:2004
  • IECEx certificate: IECEx SIR 09.0121X,
    IEC 60079-0:2007-10 Edition: 5,
    IEC 60079-1:2003 Edition: 5,
    IEC 60079-18:2009 Edition: 3,
    IEC 60079-7:2006-07 Edition: 4,
    IEC 61241-1:2004 Edition: 1
  • SIL 2 certified to IEC 61508 (2010)

Specification
GNExCP6B: II 2G Ex d e mb IIC T4 Gb
II 2D Ex t IIIC T80°C Db
IP66
Ambient: Ta = -40°C to +50°C/+55°C [-40° to +122°F/+131°F
Ingress protection: IP66
Housing material: GRP - glass reinforced polyester (UV stable)
Colour: RAL3000 Red (others available on request)
Cable entries: 2 x M20 clearance top and 1 x M20 clearance side. Back box can be rotated to give 2 x bottom and 1 x side entries.
Stopping plugs: 2 x Ex enylon plugs as standard Brass and stainless steel plugs optional
Terminals: 6 × 4.0mm2 / 8 × 2.5mm2
Test: Test:
Weight: 1.2Kg/2.64Ibs
Note: For applications that do not require monitoring resistors, diodes or inidcator LED’s please see the GNExCP6A-BG version.
The GNExCP6B call point can contain a maximum of two resistor or diode E.O.L. or series modules. The LED indicator can be combined with an EOL resistor or diode.
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)8531909000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> CALL POINTS :    47 Items found.
BExCP3B-PT-ST-NL-RD-06
(5138)

E2S  BExCP3B-PT-ST-NL-RD-06

E2S BExCP3B-PT Push Button Manual Call Point (Tool resettable) for alarm systems in Zones 1, 2, 21 & 22. B type (choose of end of line devices). LM6 aluminium enclosure. 470R 24Vdc. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BGWNNNNN100DSNNN7R
(4159)

MEDC  BGWNNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Weatherproof and dust proof only (Uncertified). IP66 & IP67. Designed for use in hazardous locations and harsh environmental conditions.

Configure

$477.46 
BGIBNNNN100DSNNN7R
(4157)

MEDC  BGIBNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exia (Intrinsically Safe). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 1GD. GOST R, CQST and Inmetro approvals also available.

Configure

$494.64 
GNEXCP6B-PB-SNSNRD06
(6444)

E2S  GNEXCP6B-PB-SNSNRD06

E2S GNExCP6B-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

GNEXCP6A-PB-SNNRD
(4087)

E2S  GNEXCP6A-PB-SNNRD

E2S GNExCP6A-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

GNEXCP6A-PT-SNNRD
(4088)

E2S  GNEXCP6A-PT-SNNRD

E2S GNExCP6A-PT Push Button Manual Call Point (Tool resettable) for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

GNEXCP6B-PT-SNSNRD06
(6445)

E2S  GNEXCP6B-PT-SNSNRD06

E2S GNExCP6B-PT Tool Reset Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

PBUWNNNN0DSNNN7R
(4212)

MEDC  PBUWNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof only version. Designed for use in hazardous locations and harsh environmental conditions.

Configure

$541.92 
PBIBNNNN0DSNNN7R
(4209)

MEDC  PBIBNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 1GD, Ex ia IIC T4 Ga, Ex ia IIIC T135C Da. CUTR, Inmetro and CQST certifications also available.

Configure

$559.15 
BGEBNNNN100DSNNN7R
(1573)

MEDC  BGEBNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exed (Increased Safety). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2G. GOST R, CQST and Inmetro approvals also available.

Configure

$615.05 
BGULNNNN100DSNNN6R
(4158)

MEDC  BGULNNNN100DSNNN6R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected. Designed for use in hazardous locations and harsh environmental conditions. NEMA 4X and 6. UL approved for Class I, Div 2 and Class II, Div 2 Groups A, B, C and D. Weatherproof only version (for Ordinary Locations) also available.

Configure

$670.91 
PBULNNNN0DSNNN7R
(4211)

MEDC  PBULNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. UL Listed for Class 1, Div 2, Groups A,B,C,D, Class II, Div 2, Groups F & G.

Configure

$679.51 
PBICNNNN0DSNNF7R
(4210)

MEDC  PBICNNNN0DSNNF7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. CSA Certified, Class 1, Groups A,B,C,D

Configure

$683.83 
PBEBNNNN0DSNNN7R
(1574)

MEDC  PBEBNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2GD. EExed IIC T6 (T4 if resistors fitted). CUTR, Inmetro and CQST certifications also available.

Configure

$692.54 
D1XCP1PSDXSNNRD
(6407)

E2S  D1XCP1PSDXSNNRD

E2S D1xCP1-PS Explosion Proof Manual Alarm Pull Station for use in harsh operating environments and hazardous locations. NEMA 4X cast aluminium housing. DPDT switch. UL and FM listed.



 
XAL-53
(6225)

NOTIFIER  XAL-53

Notifier XAL-53 Explosion Proof / Weather Proof Pull Station with Ring. Copper Free Aluminum Enclosure and 3/4" NPT conduits. Suitable for Class I Div 1, Class II Div 1 & 2 and Class III on Hazardous Locations. NEMA 7. UL and CSA Approvals.



 
SM87PBLAI_NNNNNNNNNR
(4219)

MEDC  SM87PBLAINNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Intrinsically Safe (Exia), Exd, Weatherproof. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 1G, Ex ia IIC T4 Ga. CSA, CUTR, IECEx and Inmetro versions also available.

Configure

$1,230.09 
SM87PBLAULNNNNNNN_N_N_R
(4220)

MEDC  SM87PBLAULNNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Intrinsically Safe (Exia), Exd, Weatherproof. Push Button Latching Key Reset version. Designed for the most harduous environmental conditions. UL Listed: Class 1, Div 1 Groups C & D. UCL version also available.

Configure

$1,294.65 
SM87PBLAD_NNNNNNNNNR
(1575)

MEDC  SM87PBLADNNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Exd, Weatherproof. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 2 GD, Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db. CSA, CUTR, IECEx and Inmetro versions also available.

Configure

$1,346.25 
SM87_BGLAI_NNNNNNNNNR
(4192)

MEDC  SM87BGLAINNNNNNNNNR

MEDC SM87BG Manual call point with breakglass. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 1G, Ex ia IIC T4 Ga. CSA (Class I Groups A-D), CUTR, IECEx, Inmetro and CQST versions also available.

Configure

$1,359.12 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.