Notifier Hs-ncm-mf | Notifier | Accessories | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   HS-NCM-MF

NOTIFIER HS-NCM-MF__
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier HS-NCM High-Speed Network Communications Module. Single or Multi-mode versions available. Allow connection from Notifier Panels to NOTI•FIRE•NET™ with a fiber-optic cable or twisted-pair wire. NFPA Style 4 (Class B) or Style 7 (Class A) operation. 24 VDC, 100Mb baud transmission rate. UL, ULC, CSFM and FM approved.

HS-NCM-MF   
Please Email us your request for quote   

Mode

 4 Weeks  ]
6 Variants of base SKU

The High-Speed Network Communications Module (HS-NCM) provides NOTIFIER’s NFS-320, NFS-640, NFS2-640, NFS-3030, and NFS2-3030 Fire Alarm Control Panels, NCA and NCA-2 Network Control Annunciators, and DVC Digital Voice Command with a means to connect to High-Speed NOTI•FIRE•NET™ (NFN). Six types of HS-NCM are available:

  • HS-NCM-MF for connecting nodes with multi-mode fiber-optic cable
  • HS-NCM-SF for connecting nodes with single-mode fiber-optic cable
  • HS-NCM-MFSF for connecting multimode and single-mode fiber optic mediums on the same network.
  • HS-NCM-W-2 for connecting nodes with twisted-pair wire
  • HS-NCM-WMF-2 for connecting wire and multimode fiber-optic medium on the same network
  • HS-NCM-WSF-2 for connecting wire and single-mode fiber-optic mediums on the same network

Each HS-NCM can accommodate up to two node addresses. For example, one HS-NCM can provide network communication for both an NFS2-640 and an NCA-2.

When not connected to a fire alarm panel, the HS-NCM defaults to repeater mode and can be used to boost signal distances or to pass data transmissions between two differently configured network seg- ments when wire and fiber co-exist on a network.

NOTE: Correct configuration is dependent on network design; refer to the High-Speed NFN Manual, P/N 54013.

For further information and diagrams, refer to the HS-NCM Manual, P/N 54014.

HS-NCM-MF and HS-NCM-SF Features
  • Supports fiber-optic medium
  • NFPA Style 4 (Class B) or Style 7 (Class A) operation
  • Data is immune to all environmental noise
  • Optical isolation prevents ground loops
  • High-Speed NFN fiber-optic medium
  • Fiber type: 62.5/125 micrometers (multi-mode); 50/125 micrometers (multimode), or 9/125 micrometers (single mode)
  • Maximum attenuation: 10 dB with 62.5/125 µm cable, 6.5 dB with 50/125 µm cable, and 30 dB with 9/125 µm cable
  • Wavelength (1): 1310 nanometers
  • Connectors: LC style
  • Baud transmission rate: 100 Mb
  • Data is regenerated at each node
  • Two network ports to allow simultaneous connection to fire alarm control panel and to programming computer
  • Enables software and database upload/download over the High-Speed NFN

HS-NCM-MF/SF Interconnections: When wiring consecutive nodes/repeaters, fiber cable must exit one board on Transmit (TX) and enter the next node/repeater on Receive (RX). The fiber-optic pair (RX, TX) from Port A of one node/repeater connects to Port B of another node/repeater. A HS-NCM-MF/SF may be connected to any of the following devices:

  • HS-NCM-MF/SF (respectively) on another panel
  • HS-NCM-WMF-2
  • HS-NCM-WSF-2
  • HS-NCM-MFSF
HS-NCM-W-2 Features
  • Supports twisted-pair wire medium
  • NFPA Style 4 (Class B) operation or NFPA Style 7 (Class A) operation
  • Transformer coupling provides electrical isolation between nodes
  • Pluggable terminal wiring with strain relief
  • Pluggable service connector (feeds signal directly through) in the event that power must be removed from a node
  • 12 Mb transmission rate
  • Data is regenerated at each node
  • Two network ports to allow simultaneous connection to fire alarm control panel and to programming computer
  • Enables software and database upload/download over the High-Speed NFN
  • Up to 3,000 feet (914.4 m) between nodes in a point-to-point fashion (actual distance varies with wire quality)

HS-NCM-W-2 Interconnections: When wiring consecutive HS- NCM-W-2 boards, wiring may enter or exit at Port A or Port B. HS- NCM-W-2 port-to-port wiring is polarity sensitive; use of Port A or Port B is not arbitrary. An HS-NCM-W-2 may be connected to any of the following devices:

  • HS-NCM-W-2 (in another panel)
  • HS-NCM-WMF-2
  • HS-NCM-WSF-2

HS-NCM-W-2 Switch Functions: The HS-NCM-W provides one set of switches to simplify network setup. Enable ground fault detection by setting the “ON” switch SW4-1 (Channel A); switch SW4-2 (Channel B).

HS-NCM-WMF-2, HS-NCM-WSF-2, and HSNCM-MFSF Features
  • Supports twisted-pair wire and fiber-optic medium
  • NFPA Style 4 (Class B) operation or NFPA Style 7 (Class A) operation
  • Allows wire and fiber optic nodes to communicate as one network
  • Fiber type: 62.5/125 micrometers (multi-mode); 50/125 micrometers (multimode), or 9/125 micrometers (single mode)
  • Maximum attenuation is 10 dB with 62.5/125 µm cable, and 6.5 dB with 50/125 µm cable, and 30 dB with 9/125 µm cable
  • Wavelength (1): 1310 nanometers
  • Pluggable service connector (feeds signal directly through) in the event that power must be removed from a node
  • Data is regenerated at each node
  • Two network ports to allow simultaneous connection to fire alarm control panel and to programming computer
  • Enables software and database upload/download over the High-Speed NFN
  • Up to 3,000 feet (914.4 m) between nodes in a point-to-point fashion (actual distance varies with wire quality)

HS-NCM-WMF-2/WSF-2/MFSF Interconnections: When wiring consecutive nodes/repeaters, fiber cable must exit one board on Transmit (TX) and enter the next node/repeater on Receive (RX). The fiber-optic pair (RX, TX) from Port A of one node/ repeater con- nects to Port B of another node/repeater. An HSNCM- WMF-2/WSF- 2/MFSF may be connected to any of the following devices:

  • HS-NCM-WMF-2
  • HS-NCM-WSF-2
  • HS-NCM-MFSF (on another panel)
  • HS-NCM-MF
  • HS-NCM-SF
Mounting

All models of the HS-NCM can be installed in any standard chassis such as the CHS-4L, CHS-M2, CHS-M3, CHS-4N or CPU2-640 chassis (see panel sheets). Additionally, the HS-NCM-W-2 can be door-mounted on the ADP-4B dress panel on a single-space blank plate (BMP-1) for mounting in an CAB-4 Series cabinet.

Agency Listings and Approvals

The following listings and approvals apply to the HS-NCM. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult Honeywell for the latest listing status.

  • UL Listed: S635
  • ULC Listed: S635
  • CSFM approved: 7300-0028:0257, 7165-0028:0224
  • FM approved
  • FDNY: Pending

Common Specifications
Temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (non-condensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the useful life of the system’s standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F).
Weight: HS-NCM-MFSF, HS-NCM-MF, HS-NCM-SF: 5.2 ounces (147.4 grams)
HSNCM-W-2, HS-NCM-WMF-2, HS-NCM-WSF-2: 5.75 ounces (163 grams)
Power supply: 24 VDC @ 400 mA

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    2 Items found.
NCD
(7024)

NOTIFIER  NCD

Notifier NCD Network Control Display annunciator for NOTIFIER INSPIRETM and ONYX® series fire alarm control panels. 24 VDC. USB C, USB Micro, and USB A. Trouble Relay.



 
NFS-320
(2039)

NOTIFIER  NFS-320

NOTIFIER by Honeywell ONYX Series NFS-320 Intelligent Addressable Fire Alarm Control Panel. Certified for seismic and marine applications. Supports up to 159 detectors and 159 modules. Standard 80-character display and 6A power supply. Built-in Alarm, Trouble, Security and Supervisory relays, FlashScan network prototol. *** UNPREDICTABLE LEAD TIME ****

> NOTIFIER :    37 Items found.
LDM-32
(6870)

NOTIFIER  LDM-32

Notifier LDM-32 Lamp Driver Module for annunciation and control of NOTIFIER Intelligent Fire Alarm Control Panels. Up to 32 alarm indications. 24 VDC. EIA-485 interface. UL, ULC, MEA, CSFM and FM Listed.



 
BAT-12120-BP
(6940)

NOTIFIER  BAT-12120-BP

Notifier BAT-12180-BP rechargeable battery. 12VDC. 12 AH. 4-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-1250-BP
(6942)

NOTIFIER  BAT-1250-BP

Notifier BAT-1250-BP rechargeable battery. 12VDC. 5 AH. 10-unit bulk pack, Overcharge protected. ABS high-impact case.



 
XP6-R
(6930)

NOTIFIER  XP6-R

Notifier by Honeywell XP6-R(A) Six Relay Control Module with Form-C Relays. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan® or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP6-C
(5122)

NOTIFIER  XP6-C

Notifier XP6-C Six Circuit Supervised Control Module for horns, strobes or bells that require an external power supply. Short-circuit-protection. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan® or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP10-M
(3724)

NOTIFIER  XP10-M

Notifier XP10-M Ten Input Monitor Module for intelligent alarm systems. Up to 10 addresable Class B or 5 addressable Class A devices. SLC inputs. Green LED indicators. Flexible mounting options. FlashScan® or CLIP operation. UL Listed. CSFM, FM, MEA and MSTM approved.



 
PSE-6
(6924)

NOTIFIER  PSE-6

Notifier PSE-6 (6 amp) or PSE-10 (10 amp) 24 VDC Remote Power Supply Expander with battery charger for 12 or 24 volt alarm control panels (FACP). Up to 7 outputs. UL, ULC, CSFM and FM listed.

APS2-6R
(6938)

NOTIFIER  APS2-6R

Notifier APS2-6R 6.0 Amp Auxiliary Power Supply for the Onyx Series control panels. 150 watt. 24 VDC. SLC circuit. UL, FM and CSFM listed.

BAT-121000
(6939)

NOTIFIER  BAT-121000

Notifier BAT-121000 rechargeable battery. 12VDC. 100 AH. Overcharge protected. ABS high-impact case.



 
NCM-F
(3507)

NOTIFIER  NCM-F

Notifier NCM-F or NCM-W network communication module for NOTIFIER Intelligent Fire Alarm Control Panels and Annunciators. Fiber optic or twisted-pair wire connection. 24 VDC.

HPFF12
(6600)

NOTIFIER  HPFF12

Notifier HPFF12(E) 12 Amp and 24 Volt Power Supply to extend the power of existing Notification Appliance Circuits (NACs) or provide power for auxiliary devices. 4 NAC and 1 aux outputs. 8 status LEDs. UL, CSFM and FM listed.

KDM-R2
(6932)

NOTIFIER  KDM-R2

Notifier KDM-R2 Keyboard Display Module for CPU2-640. 80 character display and QWERTY programming keypad included.



 
ACPS-610
(6936)

NOTIFIER  ACPS-610

Notifier ACPS-610 Addressable Charger/Power Supply. Provides 6 amps of shared power to four outputs or 10 amps as an external battery charger. SLC circuit. UL, ULC, CSFM and FM listed.

AMPS-24
(6937)

NOTIFIER  AMPS-24

Notifier AMPS-24 Addressable Power Supply for NFS-3030, NFS2-3030 and NCA-2. Charges 7 AH to 200 AH batteries. SLC circuit. UL, ULC, CSFM and FM listed.

LEM-320
(6872)

NOTIFIER  LEM-320

Notifier LEM-320 Loop Expander Module for NOTIFIER’s ONYX® Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.



 
LCM-320
(6871)

NOTIFIER  LCM-320

Notifier LCM-320 Loop Control Module for NOTIFIER’s ONYX® Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.



 
CPU2-3030D
(6931)

NOTIFIER  CPU2-3030D

Notifier CPU2-3030D Central processing unit for an NFS2-3030 system. Keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control keypad. Requires an AMPS-24(E) power supply.

Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.