Notifier APS2-6R 6.0 Amp Auxiliary Power Supply for the Onyx Series control panels. 150 watt. 24 VDC. SLC circuit. UL, FM and CSFM listed.

APS2-6R   
Please Email us your request for quote   

Voltage

   13 Weeks  ]

The APS2-6R is a state-of-the-art, 150 watt, switching auxiliary power supply providing 24 VDC of filtered DC power. The APS2- 6R provides three 24 VDC output circuits, rated for 6.0 Amps in alarm and 4.0 Amps continuous. It is used for the operation of peripheral audible/visual devices (alarm signaling appliances) for the Onyx Series control panels.

The APS2-6R can also be used with Legacy panels. Please refer to the APS2-6R manual for more information.

Features
  • UL 864 Ninth Edition compliant
  • Lightweight, compact design
  • 120 or 220/240 VAC (@ 50/60 Hz) versions
  • Output circuits with overload protection
  • Built-in “brown-out” circuitry
  • Diagnostic trouble LED
  • Plug-in connector for in-cabinet applications and screw terminals for remote device applications
  • Trouble supervision bus
  • Shares battery and charger circuit with control panel
  • Power-limited design, per UL requirements
  • AC Fail supervision and reporting with field-selectable delay per UL 864
  • Heavy-duty clamp-type terminals accept up to 12 AWG (3.1 mm²) wire
  • Battery voltage supervision
  • Low battery disconnect
  • Mounts in a standard CAB-3/XLS-ADT-CAB-4 Series cabinet.
Construction and Operation

When used with the CAB-3 or CAB-4 Series (CAB-A3/-A4, -B3/- B4, -C3/-C4, or -D3/-D4 one to four tiers), the APS2-6R mounts to a CHS-4 or CHS-4L mounting chassis. If more than one APS2-6R is necessary to satisfy Audible/Visual (DC) power requirements, connect additional APS2-6R power supplies together as described in the Installation Instruction Manual #53232.

Underwriters Laboratories requires that all Signaling Appliances be approved for use with the selected control system due to volt- age operating range criteria. Use only those appliances listed for use with the associated control system. Refer to Device Compati- bility Document #15378.

Installation Standards and Codes

This power supply complies with the standards set forth by the fol- lowing regulatory agencies:

NFPA Standards
  • NFPA 72 National Fire Alarm Code
Underwriters Laboratories:
  • UL 864 Standard for Control Units and Accessories for Fire Alarm Systems.

In addition, the installer should be familiar with the following standards:

  • NEC Article 300 Wiring Methods
  • Applicable Local and State Building Codes
  • Requirements of the Local Authority Having Jurisdiction
  • The Canadian Electrical Code, Part 1
Agency Listings and Approvals

The listings and approvals below apply to the basic APS2-6R. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL/ULC S635
  • FM Approved
  • CSFM: 7315-0028:248
  • FDNY: COA #6028

Specifications
ELECTRICAL SPECIFICATIONS
AC primary input power (TB1):APS2-6R: 120 VAC, 50/60 Hz, 2.9 A., APS2-6RE : 220-240 VAC, 50/60 Hz, 1.5 A.
DC secondary input power (TB3):TB3-1 (+), TB3-2 (–).
24 VDC output power (TB2):Total 6.0 A (4.0 A continuous). Cir- cuit 1 (TB2-1, TB2-2): 3.0 A @ 24 VDC power-limited. Circuit 2 (TB2-3, TB2-4): 3.0 A @ 24 VDC power-limited.
24 VDC output power (J9):6.0 A (4.0 A continuous), Non-Power Limited.
Relay Contacts (TB4):AC Fail supervision over the SLC. Fuse: (F2 battery supervision): 32 VAC, 10.0 A, Fast-A
Fuse: (F2 battery supervision):32 VAC, 10.0 A, Fast-Acting Automotive Minifuse.
Trouble supervision bus:J3 output: Form-A contact (open collector).
J4 input: Form-A contact (open collector).
J3 and J4 can be interchanged.
Loss of AC indication:Immediate indication (default); 1-2 hour delay (cut JP2); 2-3 hour delay (cut JP2 and JP3).
MECHANICAL SPECIFICATIONS
The APS2-6R measures approximately 8.625" (21.91 cm) x 6.625" (16.83 cm) x 2.375” (6.03 cm) and weighs approximately 2 lbs (0.91kg).
Export Info
Made inMexico

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    5 Items found.
NCA-2RETRO
(3509)

NOTIFIER  NCA-2RETRO

Notifier NCA-2RETRO kit for ONYX Series fire control panels



 
ACPS-610
(6936)

NOTIFIER  ACPS-610

Notifier ACPS-610 Addressable Charger/Power Supply. Provides 6 amps of shared power to four outputs or 10 amps as an external battery charger. SLC circuit. UL, ULC, CSFM and FM listed.

AMPS-24
(6937)

NOTIFIER  AMPS-24

Notifier AMPS-24 Addressable Power Supply for NFS-3030, NFS2-3030 and NCA-2. Charges 7 AH to 200 AH batteries. SLC circuit. UL, ULC, CSFM and FM listed.

NCA-2
(3508)

NOTIFIER  NCA-2

Notifier NCA-2 for ONYX Series fire control panels



 
NFS-320
(2039)

NOTIFIER  NFS-320

NOTIFIER by Honeywell ONYX Series NFS-320 Intelligent Addressable Fire Alarm Control Panel. Certified for seismic and marine applications. Supports up to 159 detectors and 159 modules. Standard 80-character display and 6A power supply. Built-in Alarm, Trouble, Security and Supervisory relays, FlashScan network prototol. *** UNPREDICTABLE LEAD TIME ****

> NOTIFIER :    35 Items found.
B300-6
(7063)

NOTIFIER  B300-6

Notifier B300-6 Standard 6” Intelligent Base

SMB500-WH
(4022)

NOTIFIER  SMB500-WH

Notifier System Sensor Surface Mount Box



 
SB-10
(6935)

NOTIFIER  SB-10

Notifier SB-10 (Metal) or SB-I/O (Plastic) Surface Backbox for Notifier NBG-10 or NBG-12 pull stations.

B501-WH
(7067)

NOTIFIER  B501-WH

Notifier B501 4” standard European flangeless mounting base. UL/ULC listed.

SPCWL
(7068)

NOTIFIER  SPCWL

Notifier SPCWL Indoor Selectable-Output Speaker for Ceiling Applications (520 Hz). 12- or 24-volt operation. UL, ULC, FM and CSFM approved.



 
FMM-1
(3695)

NOTIFIER  FMM-1

Notifier FMM-1/FMM-101 Series Monitor Module for supervised dry-contact input devices or monitor and power two-wire circuits. Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and US Coast Guard Approved.

HWL-LF
(7065)

NOTIFIER  HWL-LF

Notifier HRL-LF or HWL-LF Low frequency wall sounder (520 Hz). Plastic housing. Includes universal mounting plate. NFPA compliance. UL Listed.

B200S-WH
(6928)

NOTIFIER  B200S-WH

Notifier B200S-WH Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. Only compatible with the NFS-320, NFS2-640 and NFS2-3030 operating version with version 15.0 or higher panel firmware.



 
FRM-1
(3694)

NOTIFIER  FRM-1

Notifier FRM-1 Series Relay Module for activation of auxiliary devices (fans, dampers, etc). Two-wire SLC loop. Two Form-C dry contacts. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



 
FCM-1
(3236)

NOTIFIER  FCM-1

Notifier FCM-1 Series Addressable Control Module for Notification Appliances (horns, strobes, speakers, etc). Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



 
B210LPBP
(4141)

NOTIFIER  B210LPBP

Notifier B210LPBP Flanged Mounting Intelligent Base (10 Pack)



 
FDM-1
(6597)

NOTIFIER  FDM-1

Notifier FDM-1 Series Monitor Module to supervise, monitor and power Style B dry-contact input devices with two-wire circuits. Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and US Coast Guard Approved.



 
B200S-LF-WH
(7066)

NOTIFIER  B200S-LF-WH

Notifier BS200S-LF Low Frequency Intelligent, programmable sounder base (520 Hz). Meest NFPA 72.

FCM-1-REL
(4143)

NOTIFIER  FCM-1-REL

Notifier FCM-1-REL(A) Series Releasing Control Module for fire suppresion releasing applications. Reports the panel status as NORMAL, OPEN or SHORT CIRCUIT. Analog communications. FlashScan operation. 15 to 32 VDC. UL, FM and CSFM Approved.



 
BAT-12180-BP
(4140)

NOTIFIER  BAT-12180-BP

Notifier BAT-12180-BP rechargeable battery. 12VDC. 18 AH. 2-unit bulk pack, Overcharge protected. ABS high-impact case.



 
PF24V
(3237)

NOTIFIER  PF24V

Notifier PF24V ExitPoint Directional Sounder with Voice Messaging designed for open areas, corridors or stairs. Reduces evacuation times up to 75%. 24VDC. UL, FM, CSFM and MEA Approved.



 
BAT-1270-BP
(6944)

NOTIFIER  BAT-1270-BP

Notifier BAT-1270-BP rechargeable battery. 12VDC. 7 AH. 5-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-12260-BP
(6941)

NOTIFIER  BAT-12260-BP

Notifier BAT-12260-BP rechargeable battery. 12VDC. 26 AH. 2-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-12550
(6943)

NOTIFIER  BAT-12550

Notifier BAT-12550 rechargeable battery. 12VDC. 55 AH. Overcharge protected. ABS high-impact case.



 
ISO-6
(6934)

NOTIFIER  ISO-6

Notifier ISO-6 Six Fault Isolator Module for Notifier Fire Alarm Control Panels (FACPs). Powered by SLC loop. Class B isolator circuits. UL, FM, CSFM Approved.



 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.