Calibration Technologies Gg-o2-c0 | Oxygen | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

CALIBRATION TECHNOLOGIES   GG-O2-C0

CALIBRATION TECHNOLOGIES GG-O2-C0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
CTI GasGuard O2 Oxygen Electrochemical Sensor (15-25% or 0-25%) for gas leak detection in food air quality monitoring, refrigeration systems, confined space and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

GG-O2-C0   
1,088.34

Gas Range
Enclosure
Relay Output
RM420 Relay Output

 In Stock  ]
2 Variants of base SKU
Key Features

  • Oxygen specific electrochemical sensor technology
  • “Long life” galvanic cell - up to10 years life at 20.9%
  • Industry standard linear 4/20 mA output
  • Corrosion, weather and chemical resistant polycarbonate sensor enclosure
  • Temperature and moisture control for improved cell life
  • Sensor designed to adapt to any harsh environment from +10°F to +125°F
  • Accurately monitor oxygen deficiency or enrichment levels for personnel protection
  • Real-time continuous monitoring for early leak detection.
  • Two ranges available: 15-25% (standard), or 0-25%

The GasGuard O2 utilizes a proven galvanic cell type oxygen sensor. With a large capacity electrolyte reservoir for exceptional cell life, the GasGuard O2 electrochemical cell is designed with excellent chemical durability, and is not affected by interference gases such as carbon dioxide.

Every GasGuard O2 sensor comes equipped with an internal temperature control designed to perform in the harshest of areas. The controlled environment provides temperature and moisture control for extended cell life. The high-quality injection-molded polycarbonate enclosure offers excellent chemical corrosion protection and high impact resistance.

The GasGuard O2 provides an industry standard linear 4/20 mA output signal compatible with most gas detection systems and PLCs. The output signal is not affected by drastic temperature variations such as washdown and defrost cycles, and is minimally affected by barometric pressure changes.

Applications

  • Air Quality Monitoring
  • Refrigeration Systems
  • Confined Space
  • Tank Rooms
  • Food Processing
  • Breweries
Benefits

  • Low cost of ownership
  • Simple operation
  • Rugged and reliable

No more hidden “adder” costs for stainless steel or heated boxes. The standard GasGuard O 2 sensor is designed to work anywhere, and at a lower base-model price than most of our competition. With the rugged extended life cell, the GasGuard O 2 sensor with give you years of trouble-free operation resulting in an extremely low cost of ownership. We typically recommend a 19.5% alarm setpoint for oxygen deficiency monitoring for personnel protection. 23.5% is usually desirable for oxygen enrichment situations.

From hot mechanical rooms, to acid washdowns of processing areas, the GasGuard O 2 is prepared to survive in just about any harsh industrial condition. Every circuit board is sealed forever in potting compound, protecting electronic components and copper tracing from corrosion. A specially vented chemical- resistant polycarbonate enclosure protects the sensor from accidental damage, weather and even direct hose-hits from clean-up crews. A stainless steel enclosure is also available for applications that require it.

Specifications
DETECTION PRINCIPLE: Galvanic Electrochemical
DETECTION METHOD: Diffusion
GASES: Oxygen (O2)
RANGES: 0/15% Vol (standard)
0/25% Vol
OUTPUT SIGNAL: Linear 4/20 mA (max input impedance: 700 Ohms)
POWER SUPPLY: +24 VDC, 250 mA
PRESSURE LIMITS: 0.5 to 1.5 Atmosphere. Output signal is directly proportionate to ambient pressure changes
RESPONSE TIME: T50 = less than 30 seconds
T90 = less than 60 seconds
ACCURACY: +/- 5% of value, but dependant on calibration gas accuracy and time since last calibration
ZERO DRIFT: Less than 0.5% of full-scale per month, non-cumulative
SPAN DRIFT: Less than 0.5% of full-scale per month, non- cumulative
LINEARITY: +/- 0.5% of full-scale
REPEATABILITY: +/- 1% of full-scale
WIRING CONNECTIONS: 3 conductor, shielded, stranded, 20 AWG cable (General Cable C2525A or equivalent) up to 1500 ft.
ENCLOSURE: Injection-molded NEMA 4X polycarbonate
Hinged lid with captive screw. For non-classified areas.
TEMPERATURE RANGE: +10°F to +125°F (-12°C to +52°C)
HUMIDITY RANGE: 5% to 100% condensing
DIMENSIONS: 7.5” high x 6.5” wide x 3.75” deep
WEIGHT: 3 lbs
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    10 Items found.
CK-Cup-Hose
(2982)

CALIBRATION TECHNOLOGIES  CK-Cup-Hose

Standard cup, large cup & 3 ft hose



$35.89 
CK-CUPSET
(7107)

CALIBRATION TECHNOLOGIES  CK-CUPSET

Cup Set, Calibration Fits Sensor Diameters 0.625, 0.875, 1, 1.25, 1.75 (inches)



$59.17 
RM420-LR
(5805)

CALIBRATION TECHNOLOGIES  RM420-LR

Calibration Technologies Adjustable Setpoint Relay, 24Vdc 4-20mA to relay module, fail-safe relay output to any 4-20 mA device. SPDT relay, Form C contacts.



$193.03 
SHA-024-B
(2987)

CALIBRATION TECHNOLOGIES  SHA-024-B

CTI SHA-24 100dB Horn/Strobe 24 VDC. White body and blue lens. With weather proof mounting backbox. UL1638 approved.

Configure

$226.01 
SHA-120-B
(2988)

CALIBRATION TECHNOLOGIES  SHA-120-B

CTI SHA-120 99dB Horn/Strobe 120 VAC. White body and blue lens. With weather proof mounting backbox. UL Listed. NEMA 4X enclosure.

Configure

$253.17 
SHA-PY-120-B
(7080)

CALIBRATION TECHNOLOGIES  SHA-PY-120-B

CTI SHA-PY-120 Horn and Strobe. Weather-proof. 120 VAC. Two or three wire connection. High intensity 5 Joules Xenon flash and 8 selectable horn tones. Wall or ceiling mount. NEMA 4X. UL listed.

Configure

$329.80 
SL3-_24-R____-B
(6570)

CALIBRATION TECHNOLOGIES  SL3-24-R-B

CTI SL3 LED stack light with 105 dB buzzer. Up to 5 24VDC or 120VAC Flashing light modules (62 fpm). Polycarbonate Housing. 1/2" NPT conduit. IP66. NEMA 4X. UL listed.

Configure

$446.20 
EM2-24
(2971)

CALIBRATION TECHNOLOGIES  EM2-24

CTI EM2 Gas Detection Entrance Monitor Controller/Alarm Panel for stand-alone or feed-through applications. 8A SPDT relay, 3" LCD display, 4-20 mA input and NEMA 4X enclosure. IP68.

Configure

$615.95 
GG-2
(2972)

CALIBRATION TECHNOLOGIES  GG-2

CTI GasGuardian 2 2-Channel Controller/Alarm Panel for simultaneously monitor of two sensor locations. 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.



$2,027.30 
GG-6
(2973)

CALIBRATION TECHNOLOGIES  GG-6

CTI GasGuardian 6 6-Channel Controller/Alarm Panel for simultaneously monitor of up to 30 sensors (with expansion modules). 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.

Configure

$4,062.36 
> OXYGEN :    29 Items found.
51001AL-0-1010/25V/L0
(7131)

RC SYSTEMS  51001AL-0-1010/25V/L0

RC Systems SenSmart 5100 3-wire gas detector for Oxygen (O2) 0-25% vol. with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
967-343490-25P
(6065)

DETCON  967-343490-25P

Detcon DM-700-O2 Electrochemical Smart Oxygen (O2) 0-25% Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

SPXCDULNO2
(5108)

HONEYWELL  SPXCDULNO2

Honeywell Sensepoint XCD RTD Gas Detector for Oxygen (O2) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 25% v/v. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,735.82 
961-340026-025G
(6372)

DETCON  961-340026-025G

Detcon DM-100-O2 Electrochemical Oxygen (O2) 0-25%vol Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

2100AL-0-9010/25V/L0
(116)

RC SYSTEMS  2100AL-0-9010/25V/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Oxygen (O2) 0-25% vol. with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,789.61 
31001AL-0-9010/25V/L0
(5787)

RC SYSTEMS  31001AL-0-9010/25V/L0

RC Systems SenSmart 3100 3 wire gas detector for Oxygen (O2) 0-25% vol. with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
XNXUTAENNNNN-XNXXSO1SS
(849)

HONEYWELL  XNXUTAENNNNN-XNXXSO1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Oxygen (O2) 0-25%VOL compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$1,969.63 
6100AL1-0-1010/0025P
(7013)

RC SYSTEMS  6100AL1-0-1010/0025P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Oxygen (O2) 0-25% vol with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
GG2SAXXX-X-O2
(5019)

ION SCIENCE  GG2SAXXX-X-O2

Ion Science GasCheck G2 Micro Thermal Conductivity Leak Detector (MTCD) for Oxygen (O2). Rapid and accurate. LCD back lit display, LED indicator and audible sounder. Low cost operation. *** Phased Out replaced by Panther ***

Page: 1 | 2 | All