CTI EM2 Gas Detection Entrance Monitor Controller/Alarm Panel for stand-alone or feed-through applications. 8A SPDT relay, 3" LCD display, 4-20 mA input and NEMA 4X enclosure. IP68.

EM2-24   
635.00

Power Supply

   In Stock  ]
2 Variants of base SKU
Key Features

  • At-a-glance visual indication of gas concentrations before room entry
  • Single channel
  • For stand-alone or feed-through applications
  • Onboard 8A relay with adjustable alarm setpoint
  • Large 3” diagonal LCD display operates down to -40°F (-40°C)
  • Electronics are potted to protect against water damage and corrosion
  • Industry standard linear 4/20 mA input and output
  • Calibration mode allows alarm inhibiting during maintenance or calibration
  • Watertight IP68 enclosure designed for washdown areas and outdoors
  • Use with CTI sensor line or any other 4/20 mA device

The EM2 provides plant personnel an at-a-glance visual indication before entering potentially dangerous areas. Simple menu-driven programming through the LCD operator interface, and one relay output with adjustable alarm setpoint. Great for engine rooms, air handlers, and stand-alone applications.

The EM2 can be used as a stand-alone monitor or in series with the sensor signal to provide remote display / remote relay operation. As a feedthrough device, the sensor signal is re-transmitted back to any industry standard 4/20 mA device such as a PLC or gas detection control panel.

The watertight polycarbonate enclosure will stand up to corrosive washdown, temperature swings, and any other harsh environment encountered in the food industry. The electronics are completely potted to protect against corrosion, allowing for installation in washdown areas and outdoors.

Applications

  • Compressor Room Entrances
  • Rooftop Air Handling Units
  • Confined Spaces
  • Oxygen Deficiency Monitoring
  • Remote Relay Activation and Readout
  • Stand Alone Gas Detection Controller
Benefits
  • Low cost solution
  • Remote gas concentration display
  • Remote relay output

The EM2 is a low cost solution that provides multiple configurations to meet many needs for remote display and alarm applications. Use the EM2 as a stand-alone device, or a feedthrough device to provide remote display and alarm output capability located at or near the sensor.

Since sensors often end up in wet and harsh environments, an onboard relay is not always ideal. The EM2 provides alarm activation remote of the sensor, in a safe enclosure out of harm’s way. The onboard relay is rated at 5A @ 24VDC or 8A @ 120VAC.

The EM2 provides an at-a-glance indication of dangerous gas concentrations with a large LCD. Alarm indications are displayed by a flashing ALARM status on the LCD. Calibration mode, Test mode and analog In/Out Adjust mode are handy features of the operator interface.

Specifications
Power Requirements: EM2-24: 24 VDC, 350 mA max (not including other connected devices).
EM2-120: 100-240 VAC, 0.7A 50/60 Hz
Output 24 VDC Power available for sensors and audio/visual devices:
0.75A @ 40°C (104°F).
0.50A @ 50°C (122°F).
Signal Input: 4-20 mA, 261 Ohm input impendance
Dimensions: 6.1” high x 6.0” wide x 2.8” deep (EM2-24)
6.1” high x 6.0” wide x 4.0” deep (EM2-120)
Weight: 1.5 lbs (EM2-24)
2.5 lbs (EM2-120)
Enclosure: Polycarbonate IP68, with PU gasket and hingedlid. Powder-coated aluminun mounting plate. For non-classified areas.
Temperature Range: -40°F to +122°F (-40°C to +50°C)
Humidity Range: 0-100% RH, condensing
Alarm Level Setting: 1% of scale increments.
Relay Output: (1) SPDT relay, Form C contacts, 5A @ 24 VDC or 8A @120/240 VAC
Adjustable On/Off delays
Adjustable Latching/Non-Latching
Adjustable Normally energized/de-energized
Terminal Block Plugs: (Field Wiring) 12-26 AWG, torque 4 lbs-in
Wiring Connections: 3 conductor, shielded, stranded, 18 AWG cable (General Cable C2535A or equivalent) up to 1000 ft (total length between sensor and power supply)
Analog Output: 4/20 mA (max input impedance: 700 Ohms)
LCD: Monochrome, 2.7” x 1.5” viewing area
Monitor Functions: Calibration Mode: Locks relay outputs for sensor calibration or maintenance.
Relay Test Function: Allows for easy testing of relay output function.
Adjustable Alarm Setpoint.
Downscale Alarm Setting: for Oxygen Monitoring.
Latching relay (programmable)
Failsafe relay (programmable)
Relay set/reset delays (programmable)
Deadband (programmable)
Analog in/out adjust allow fine tuning of the signal to match transmitter to EM2 to PLC
Force output mode provides adjustable analog output signal to test connected analog input device.
Real-Time Status Display: Displays gas concentrations and any current alarm conditions.
Analog input and output offset adjustment to finetune the signal and display readings.
Certification: ETL listed to UL standard 61010-1, and CSA standard C22.2 No. 61010-1-12
Warranty: 2-years
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531100045

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> 1-CHANNEL :    4 Items found.
2306B2000
(2540)

HONEYWELL  2306B2000

Zareba Unipoint simple DIN rail mounted 1-channel controller with mV bridge input; 3 alarm relays and built-in audiovisual alarms. Flexible and low cost solution to incorporate catalytic bead, bridge type gas detection into control and gas detection systems.



$511.97 
2306B1000
(1503)

HONEYWELL  2306B1000

Zareba Unipoint simple DIN rail mounted 1-channel controller with 2 wire 4-20mA, 3 wire 4-20 mA , 3 alarm relays and built-in audiovisual alarms. Flexible and low cost solution to incorporate toxic or oxygen gas detection into control and gas detection systems.



$604.31 
SPXCDULNRFD
(3000)

HONEYWELL  SPXCDULNRFD

Honeywell Sensepoint XCD RFD (Remote Flammable Detector) for use with remotely mounted catalytic bead or infrared flammable gas sensors. TRANSMITTER ONLY. Adjustable gas range from 0-100%LEL to 0-20%LEL. Tri-colour backit display. 4-20mA Output. Sensor can be mounted up to 30 metres (100 feet) from transmitter. cCSAus Certified for North America. Class 1, Div 1, Groups B, C, & D.

Configure

$1,099.87 
SPXCDALMRFD
(4155)

HONEYWELL  SPXCDALMRFD

Honeywell Sensepoint XCD RFD (Remote Flammable Detector) for use with remotely mounted catalytic bead or infrared flammable gas sensors. TRANSMITTER ONLY. Adjustable gas range from 0-100%LEL to 0-20%LEL. Tri-colour backit display. 4-20mA Output. Sensor can be mounted up to 30 metres (100 feet) from transmitter. ATEX/IECEX & AP Certified with LM25 entry.

Configure

$1,365.61 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.