CTI GasGuardian 6 6-Channel Controller/Alarm Panel for simultaneously monitor of up to 30 sensors (with expansion modules). 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.

GG-6   
4,188.00

Output Board
Power Supply
Expansion Module
Each module includes power supply and 8 relay outputs (does not include sensors).

 In Stock  ]
Key Features

  • Simultaneously monitor 6 sensors – up to 30 with expansion modules
  • Six onboard relays standard – eight more relays per expansion module
  • Alarm Log records and stores every event
  • Industry standard linear 4/20 mA input can accommodate any gas sensor
  • Simple menu-driven programming through the LCD operator interface
  • Power supply can also drive external horn/strobes
  • Watertight enclosure designed for washdown areas and outdoors
  • Configurable for GasGuard sensor line and any other 4/20 mA gas sensor
  • Horn relay silenceable from front-panel Silence key

The GG-6 can interface to, but operate independently of, plant control systems for a reliable stand- alone safety system. The GG-6 comes standard with six onboard relays, as well as an onboard buzzer. One relay is a dedicated fault relay, the other five relays are user programmable to trigger upon any event for any sensor or group of sensors.

The GG-XM expansion modules allow you to add on eight sensors for each module, up to three modules for a total of 30 sensors. Each GG-XM comes equipped with eight 4/20 mA inputs, eight programmable relays and its own power supply. Analog output boards can be added on to the controller and expansion modules, which can be connected to your plant PLC or other 4/20 mA control panel.

The watertight fiberglass enclosure will stand up to corrosive washdown, temperature swings and any other harsh environment often encountered in the food industry. The GG-XM’s connect to the GG-6 and /or each other via a 24” wire harness. Since the alarm log holds 10,000 events, yesterday’s events will not go unnoticed.

Applications

  • Engine Rooms
  • Tank Rooms
  • Mechanical Rooms
  • Sea Vessels
  • Refrigeration Systems
  • Perimeter Monitoring
  • Heat Treatment
  • Refineries
  • Chemical Plants
Benefits
  • Full-featured
  • Expandable
  • Easy configuration

The GG-6 controller utilizes a user- friendly LCD operator interface for all readout information and alarm function control. Out of the box, the controller and expansion modules are configured and ready to go with default setpoints loaded in the software. Just enter the zone location names and adjust the low the high alarm setpoints if needed.

The backlit LCD displays real-time status of gas sensor concentrations and allows for custom programming thru a user-friendly menu system. The GG-6 and expansion modules are compatible with all gas sensors with industry standard 4/20 mA inputs. The power supplies are powerful enough to power all connected sensors and external 24Vdc horn/strobes.

All wiring is safely enclosed inside and easily accessed from the hinged lids. All expansion modules connect to the GG-6 in a daisy-chain configuration. Wiring is as easy as plugging in a wiring harness. All human interfacing is performed via the waterproof membrane keys on the outside of the GG-6, for non-intrusive operation.

Specifications
AC POWER REQUIREMENTS: 110 VAC @ 2 A
DC POWER REQUIREMENTS: DC P OWER A VAILABLE F OR S ENSORS
DIMENSIONS: 15.8” high x 14” wide x 7” deep (GG-6/GG-XM)
WEIGHT: 12 lbs (GG-6/GG-XM)
ENCLOSURE: Fiberglass Reinforced Polyester NEMA 4X, with neoprene gasket. Continuous stainless steel hinge. Captive screws in lid. For non-classified areas.
TEMPERATURE RANGE: 0°F to +122°F
HUMIDITY RANGE: 0-100% RH, condensing, with proper conduit seals
RELAY OUTPUTS (6): SPDT relays, 10A @ 24 VDC or 120 VAC
10 Second On/Off delays
Selectable to Latch/Non-Latch
Status LEDs show relay state

GG-6 (Six Relays)
(6) Programmable Relays
Programmable to trigger upon any event for any sensor or group of sensors.

GG-XM (Eight Relays)
(8) Programmable Relays
Programmable to trigger upon any event for any sensor or group of sensors.
ANALOG OUTPUTS: (optional) (6) Individual 4/20 mA outputs (GG-6)
(8) Individual 4/20 mA outputs (GG-XM)
HORN: PCB mount Piezo buzzer (GG-6 only)
CONTROLLER FUNCTIONS: LCD, backlit, graphics display (GG-6 only)
8 lines x 22 characters
Waterproof membrane switches, alpha-numeric keys
Non-volatile memory
Real-Time Status Display: Displays gas concentrations and any current alarm conditions.
Alarm Log: Records and stores 10,000 events for easy recall
Calibration Mode: Locks relay outputs for sensor calibration or maintenance.
Relay Test Function: Allows for easy testing of relay output functions
Adjustable Warning and Alarm Setpoints
Adjustable Relay Latch/Non-Latch
Downscale Alarm Setting for Oxygen Monitoring
Horn Silence Button Clears Horn Relay
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531100045

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.