Autronica Bh-300 | Intelligent | Smoke | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

AUTRONICA   BH-300

SKU# (7730)
AUTRONICA BH-300
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Autronica BH-300 Optical Photoelectric Smoke Detector. PC/ABS housing. 10-27 VDC. IP44. *** Phased out ***

Please Email us your request for quote   

   14 Weeks  ]
Features
  • Interactive
  • Different sensitivity settings possible
  • Comprises the DYFI+ adaptive and self learning functions
  • SelfVerify functions for reduced maintenance/testing and increased reliability
  • Detection of visible smoke
  • Built-in thermistor for reading of temperature at the detector point
  • Short circuit isolator in each detector
  • Comprises a built-in alarm indicator (LED)
  • Automatic addressing
  • Proven technology
  • Immune to electromagnetic disturbance
  • EN 54-7/EN 54-17
  • Designed to meet the requirement of the major maritime classification societies
Applications

BH-300 is a point smoke detector for detection of combustion gases mainly consisting of visible particles. The detector has a built in thermistor and is designed for use with Autronica’s interactive fire detection systems, which can provide temperature information from the detector point. The SelfVerify function ensures the highest grade of reliability because all units comprising this function are tested with a calibrated test once every 24 hours.

The DYFI+ intelligence combined with the SelfVerify function makes this detector the obvious choice for demanding applications such as industrial, maritime and offshore installations.

Principle

Photoelectric, operating on the light scatter principle.

Use of LED output

When LED or other equipment is connected to the LED output, a varistor - Siemens SIOVS07K25 (39V) - Autronica part. no. 116-8464-003.5039, is required between terminals 1 and 4 in base. The LED is connected between terminals 3 and 4, terminal 3 being the positive terminal.

Technical Specifications
Weight 150 g
Materials PC/ABS
Colour White
Sensitivity Ref. Table 1
Voltage 10 – 27 VDC
Current consumption Stand by < 0.3mA
External alarm indicator 6mA
CPD certificate 1134-CPD-016
Degree of protection IP44
Working temperature -20 - +70°C
Humidity (non condensing) Max. 95% RH
Maintenance None
Service Replace if faulty
Approvals See web site
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531100025

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping & Handling

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> INTELLIGENT :    34 Items found.
D1xH1N01MB1A1RN
(7278)

E2S  D1xH1N01MB1A1RN

E2S D1xH1 Heat Detector for harshest of environments. Stainless steel casing and hermetically sealed contacts. Certified for Zone 1 & Zone 21, Class I Zone 1 & Zone 21, Class I/Class II Div 1 & Div 2. IECEx, ATEX, UL, ... more

SK-HEAT-W
(7727)

SILENT KNIGHT  SK-HEAT-W

Silent Knight SK-HEAT-W Series Addressable Heat Detector (135 DegreesF). Two-wire SLC connection. 15-32VDC. UL, FM and CSFM approved.



 
SD365
(7235)

NOTIFIER  SD365

Notifier SD365 Addressable Photoelectric Smoke Detector. Two-wire SLC loop connection. LiteSpeed and CLIP protocol. UL/ULC and FM Approved.



 
OSI-R-SS
(7244)

NOTIFIER  OSI-R-SS

Notifier OSI-R-SS Reflective Imaging Beam Smoke Detector. Includes standby, fault and alarm LED indicators. 10.2 to 32 VDC. UL, ULC and FM Approved.



 
D2xH1VN01AB1E1RN
(7279)

E2S  D2xH1VN01AB1E1RN

E2S D2xH1 Heat Detector for harshest of environments. Stainless steel casing and hermetically sealed contacts. Class I Zone 2 and Zone 22, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

GNExH1N01AB1E1RN
(7280)

E2S  GNExH1N01AB1E1RN

E2S GNExH1 Heat Detector for harshest of environments. Robust corrosion proof GRP termination enclosure. Class I Zone 1, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

STExH1N01AS1A1RN
(7281)

E2S  STExH1N01AS1A1RN

E2S STExH1 Heat Detector for harshest of environments. Explosion proof stainless steel enclosure. Zone 1 & Zone 21, Class I Zone 1 & Zone 21, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

MIX-2351AP
(7444)

MIRCOM  MIX-2351AP

Mircom MIX-2351AP(A) Intelligent Photoelectric Smoke Detector. 15-32 VDC. UL & ULC Listed.

SK-FIRE-CO-W
(7720)

SILENT KNIGHT  SK-FIRE-CO-W

Silent Knight SK-FIRE-CO-W Multi-Criteria Fire (smoke, light, flame and heat) and Carbon Monoxide (CO) Detector with Photoelectric, Thermal and Infrared sensors. 15-32VDC. UL, FM and CSFM Approvals.



 
2098-9489
(7521)

SIMPLEX TYCO  2098-9489

Simplex Tyco 2098-9489 Heat Detector for fixed temperature. Normally-Open contacts. UL rated.



 
4098-5601
(7528)

SIMPLEX TYCO  4098-5601

Simplex Tyco 4098-5601 Photo Detector. Rate-of-rise and fixed temperature thermistor-based detection. False alarm resistant. UL listed to standard 268.



 
SK-PHOTO-W
(7670)

SILENT KNIGHT  SK-PHOTO-W

Silent Knight SK-PHOTO-W Series Addressable Photoelectric Smoke Detector. 15-32 VDC. Inludes Two wire SLC connection and remote test capability. Available with thermal sensing (135 DegreesF) and various base options. UL, FM and CSFM Approved.



 
4098-5610
(7672)

SIMPLEX TYCO  4098-5610

Simplex Tyco 4098-5610 Heat Detector. Rate-of-rise and fixed temperature thermistor-based detection. False alarm resistant. UL listed to standard 268.

H365
(7239)

NOTIFIER  H365

Notifier H365 Addressable Intelligent Heat Detector. Two-wire SLC loop connection. Fire-resistant plastic enclosure. 15-32 VDC. UL, FM and CSFM listed.



 
SS-PHOTO
(7716)

SYSTEM SENSOR  SS-PHOTO

System Sensor SS-Photo Intelligent Photoelectric Smoke detector with point ID capability. Includes analog communications and Dual LEDs for 360 Degrees visibility. 15 to 32 VDC. UL approved.

B110LP
(7064)

NOTIFIER  B110LP

Notifier B110LP Plug-in Smoke Detector with photoelectric sensor for a wide range of combustion sources. Includes Low current draw, built-in tamper resistant base design, remote LED option, removable cover and built-in test switch. UL, ULC, FM and MEA approved.

5601P
(4021)

NOTIFIER  5601P

Notifier System Sensor Mechanical Heat Detector

4098-9733
(6852)

SIMPLEX TYCO  4098-9733

Simplex Tyco 4098-9733 TrueAlarm Analog Heat Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

4098-9612
(6854)

SIMPLEX TYCO  4098-9612

Simplex 4098-9612 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. 15 to 32 VDC. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

4098-9714
(6845)

SIMPLEX TYCO  4098-9714

Simplex Tyco 4098-9714 TrueAlarm Analog SSD Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.