NOTIFIER   APS2-6R

SKU# (6938)



NOTIFIER APS2-6R
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier APS2-6R 6.0 Amp Auxiliary Power Supply for the Onyx Series control panels. 150 watt. 24 VDC. SLC circuit. UL, FM and CSFM listed.

APS2-6R   
Please Email us your request for quote   

Voltage

   4 Weeks  ]

The APS2-6R is a state-of-the-art, 150 watt, switching auxiliary power supply providing 24 VDC of filtered DC power. The APS2- 6R provides three 24 VDC output circuits, rated for 6.0 Amps in alarm and 4.0 Amps continuous. It is used for the operation of peripheral audible/visual devices (alarm signaling appliances) for the Onyx Series control panels.

The APS2-6R can also be used with Legacy panels. Please refer to the APS2-6R manual for more information.

Features
  • UL 864 Ninth Edition compliant
  • Lightweight, compact design
  • 120 or 220/240 VAC (@ 50/60 Hz) versions
  • Output circuits with overload protection
  • Built-in “brown-out” circuitry
  • Diagnostic trouble LED
  • Plug-in connector for in-cabinet applications and screw terminals for remote device applications
  • Trouble supervision bus
  • Shares battery and charger circuit with control panel
  • Power-limited design, per UL requirements
  • AC Fail supervision and reporting with field-selectable delay per UL 864
  • Heavy-duty clamp-type terminals accept up to 12 AWG (3.1 mm²) wire
  • Battery voltage supervision
  • Low battery disconnect
  • Mounts in a standard CAB-3/XLS-ADT-CAB-4 Series cabinet.
Construction and Operation

When used with the CAB-3 or CAB-4 Series (CAB-A3/-A4, -B3/- B4, -C3/-C4, or -D3/-D4 one to four tiers), the APS2-6R mounts to a CHS-4 or CHS-4L mounting chassis. If more than one APS2-6R is necessary to satisfy Audible/Visual (DC) power requirements, connect additional APS2-6R power supplies together as described in the Installation Instruction Manual #53232.

Underwriters Laboratories requires that all Signaling Appliances be approved for use with the selected control system due to volt- age operating range criteria. Use only those appliances listed for use with the associated control system. Refer to Device Compati- bility Document #15378.

Installation Standards and Codes

This power supply complies with the standards set forth by the fol- lowing regulatory agencies:

NFPA Standards
  • NFPA 72 National Fire Alarm Code
Underwriters Laboratories:
  • UL 864 Standard for Control Units and Accessories for Fire Alarm Systems.

In addition, the installer should be familiar with the following standards:

  • NEC Article 300 Wiring Methods
  • Applicable Local and State Building Codes
  • Requirements of the Local Authority Having Jurisdiction
  • The Canadian Electrical Code, Part 1
Agency Listings and Approvals

The listings and approvals below apply to the basic APS2-6R. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL/ULC S635
  • FM Approved
  • CSFM: 7315-0028:248
  • FDNY: COA #6028

Specifications
ELECTRICAL SPECIFICATIONS
AC primary input power (TB1):APS2-6R: 120 VAC, 50/60 Hz, 2.9 A., APS2-6RE : 220-240 VAC, 50/60 Hz, 1.5 A.
DC secondary input power (TB3):TB3-1 (+), TB3-2 (–).
24 VDC output power (TB2):Total 6.0 A (4.0 A continuous). Cir- cuit 1 (TB2-1, TB2-2): 3.0 A @ 24 VDC power-limited. Circuit 2 (TB2-3, TB2-4): 3.0 A @ 24 VDC power-limited.
24 VDC output power (J9):6.0 A (4.0 A continuous), Non-Power Limited.
Relay Contacts (TB4):AC Fail supervision over the SLC. Fuse: (F2 battery supervision): 32 VAC, 10.0 A, Fast-A
Fuse: (F2 battery supervision):32 VAC, 10.0 A, Fast-Acting Automotive Minifuse.
Trouble supervision bus:J3 output: Form-A contact (open collector).
J4 input: Form-A contact (open collector).
J3 and J4 can be interchanged.
Loss of AC indication:Immediate indication (default); 1-2 hour delay (cut JP2); 2-3 hour delay (cut JP2 and JP3).
MECHANICAL SPECIFICATIONS
The APS2-6R measures approximately 8.625" (21.91 cm) x 6.625" (16.83 cm) x 2.375” (6.03 cm) and weighs approximately 2 lbs (0.91kg).
Export Info
Made inMexico

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> NOTIFIER :    41 Items found.
CPU2-3030D
(6931)

NOTIFIER  CPU2-3030D

Notifier CPU2-3030D Central processing unit for an NFS2-3030 system. Keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control keypad. Requires an AMPS-24(E) power supply.

Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.