Notifier Aps2-6r | Notifier | Accessories | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   APS2-6R

NOTIFIER APS2-6R
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier APS2-6R 6.0 Amp Auxiliary Power Supply for the Onyx Series control panels. 150 watt. 24 VDC. SLC circuit. UL, FM and CSFM listed.

APS2-6R   
Please Email us your request for quote   

Voltage

   13 Weeks  ]

The APS2-6R is a state-of-the-art, 150 watt, switching auxiliary power supply providing 24 VDC of filtered DC power. The APS2- 6R provides three 24 VDC output circuits, rated for 6.0 Amps in alarm and 4.0 Amps continuous. It is used for the operation of peripheral audible/visual devices (alarm signaling appliances) for the Onyx Series control panels.

The APS2-6R can also be used with Legacy panels. Please refer to the APS2-6R manual for more information.

Features
  • UL 864 Ninth Edition compliant
  • Lightweight, compact design
  • 120 or 220/240 VAC (@ 50/60 Hz) versions
  • Output circuits with overload protection
  • Built-in “brown-out” circuitry
  • Diagnostic trouble LED
  • Plug-in connector for in-cabinet applications and screw terminals for remote device applications
  • Trouble supervision bus
  • Shares battery and charger circuit with control panel
  • Power-limited design, per UL requirements
  • AC Fail supervision and reporting with field-selectable delay per UL 864
  • Heavy-duty clamp-type terminals accept up to 12 AWG (3.1 mm²) wire
  • Battery voltage supervision
  • Low battery disconnect
  • Mounts in a standard CAB-3/XLS-ADT-CAB-4 Series cabinet.
Construction and Operation

When used with the CAB-3 or CAB-4 Series (CAB-A3/-A4, -B3/- B4, -C3/-C4, or -D3/-D4 one to four tiers), the APS2-6R mounts to a CHS-4 or CHS-4L mounting chassis. If more than one APS2-6R is necessary to satisfy Audible/Visual (DC) power requirements, connect additional APS2-6R power supplies together as described in the Installation Instruction Manual #53232.

Underwriters Laboratories requires that all Signaling Appliances be approved for use with the selected control system due to volt- age operating range criteria. Use only those appliances listed for use with the associated control system. Refer to Device Compati- bility Document #15378.

Installation Standards and Codes

This power supply complies with the standards set forth by the fol- lowing regulatory agencies:

NFPA Standards
  • NFPA 72 National Fire Alarm Code
Underwriters Laboratories:
  • UL 864 Standard for Control Units and Accessories for Fire Alarm Systems.

In addition, the installer should be familiar with the following standards:

  • NEC Article 300 Wiring Methods
  • Applicable Local and State Building Codes
  • Requirements of the Local Authority Having Jurisdiction
  • The Canadian Electrical Code, Part 1
Agency Listings and Approvals

The listings and approvals below apply to the basic APS2-6R. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL/ULC S635
  • FM Approved
  • CSFM: 7315-0028:248
  • FDNY: COA #6028

Specifications
ELECTRICAL SPECIFICATIONS
AC primary input power (TB1):APS2-6R: 120 VAC, 50/60 Hz, 2.9 A., APS2-6RE : 220-240 VAC, 50/60 Hz, 1.5 A.
DC secondary input power (TB3):TB3-1 (+), TB3-2 (–).
24 VDC output power (TB2):Total 6.0 A (4.0 A continuous). Cir- cuit 1 (TB2-1, TB2-2): 3.0 A @ 24 VDC power-limited. Circuit 2 (TB2-3, TB2-4): 3.0 A @ 24 VDC power-limited.
24 VDC output power (J9):6.0 A (4.0 A continuous), Non-Power Limited.
Relay Contacts (TB4):AC Fail supervision over the SLC. Fuse: (F2 battery supervision): 32 VAC, 10.0 A, Fast-A
Fuse: (F2 battery supervision):32 VAC, 10.0 A, Fast-Acting Automotive Minifuse.
Trouble supervision bus:J3 output: Form-A contact (open collector).
J4 input: Form-A contact (open collector).
J3 and J4 can be interchanged.
Loss of AC indication:Immediate indication (default); 1-2 hour delay (cut JP2); 2-3 hour delay (cut JP2 and JP3).
MECHANICAL SPECIFICATIONS
The APS2-6R measures approximately 8.625" (21.91 cm) x 6.625" (16.83 cm) x 2.375” (6.03 cm) and weighs approximately 2 lbs (0.91kg).
Export Info
Made inMexico

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    5 Items found.
NCA-2RETRO
(3509)

NOTIFIER  NCA-2RETRO

Notifier NCA-2RETRO kit for ONYX Series fire control panels



 
ACPS-610
(6936)

NOTIFIER  ACPS-610

Notifier ACPS-610 Addressable Charger/Power Supply. Provides 6 amps of shared power to four outputs or 10 amps as an external battery charger. SLC circuit. UL, ULC, CSFM and FM listed.

AMPS-24
(6937)

NOTIFIER  AMPS-24

Notifier AMPS-24 Addressable Power Supply for NFS-3030, NFS2-3030 and NCA-2. Charges 7 AH to 200 AH batteries. SLC circuit. UL, ULC, CSFM and FM listed.

NCA-2
(3508)

NOTIFIER  NCA-2

Notifier NCA-2 for ONYX Series fire control panels



 
NFS-320
(2039)

NOTIFIER  NFS-320

NOTIFIER by Honeywell ONYX Series NFS-320 Intelligent Addressable Fire Alarm Control Panel. Certified for seismic and marine applications. Supports up to 159 detectors and 159 modules. Standard 80-character display and 6A power supply. Built-in Alarm, Trouble, Security and Supervisory relays, FlashScan network prototol. *** UNPREDICTABLE LEAD TIME ****

> NOTIFIER :    35 Items found.
LDM-32
(6870)

NOTIFIER  LDM-32

Notifier LDM-32 Lamp Driver Module for annunciation and control of NOTIFIER Intelligent Fire Alarm Control Panels. Up to 32 alarm indications. 24 VDC. EIA-485 interface. UL, ULC, MEA, CSFM and FM Listed.



 
BAT-12120-BP
(6940)

NOTIFIER  BAT-12120-BP

Notifier BAT-12180-BP rechargeable battery. 12VDC. 12 AH. 4-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-1250-BP
(6942)

NOTIFIER  BAT-1250-BP

Notifier BAT-1250-BP rechargeable battery. 12VDC. 5 AH. 10-unit bulk pack, Overcharge protected. ABS high-impact case.



 
XP6-R
(6930)

NOTIFIER  XP6-R

Notifier by Honeywell XP6-R(A) Six Relay Control Module with Form-C Relays. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan® or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP6-C
(5122)

NOTIFIER  XP6-C

Notifier XP6-C Six Circuit Supervised Control Module for horns, strobes or bells that require an external power supply. Short-circuit-protection. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan® or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP10-M
(3724)

NOTIFIER  XP10-M

Notifier XP10-M Ten Input Monitor Module for intelligent alarm systems. Up to 10 addresable Class B or 5 addressable Class A devices. SLC inputs. Green LED indicators. Flexible mounting options. FlashScan® or CLIP operation. UL Listed. CSFM, FM, MEA and MSTM approved.



 
PSE-6
(6924)

NOTIFIER  PSE-6

Notifier PSE-6 (6 amp) or PSE-10 (10 amp) 24 VDC Remote Power Supply Expander with battery charger for 12 or 24 volt alarm control panels (FACP). Up to 7 outputs. UL, ULC, CSFM and FM listed.

BAT-121000
(6939)

NOTIFIER  BAT-121000

Notifier BAT-121000 rechargeable battery. 12VDC. 100 AH. Overcharge protected. ABS high-impact case.



 
NCM-F
(3507)

NOTIFIER  NCM-F

Notifier NCM-F or NCM-W network communication module for NOTIFIER Intelligent Fire Alarm Control Panels and Annunciators. Fiber optic or twisted-pair wire connection. 24 VDC.

HPFF12
(6600)

NOTIFIER  HPFF12

Notifier HPFF12(E) 12 Amp and 24 Volt Power Supply to extend the power of existing Notification Appliance Circuits (NACs) or provide power for auxiliary devices. 4 NAC and 1 aux outputs. 8 status LEDs. UL, CSFM and FM listed.

KDM-R2
(6932)

NOTIFIER  KDM-R2

Notifier KDM-R2 Keyboard Display Module for CPU2-640. 80 character display and QWERTY programming keypad included.



 
LEM-320
(6872)

NOTIFIER  LEM-320

Notifier LEM-320 Loop Expander Module for NOTIFIER’s ONYX® Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.



 
LCM-320
(6871)

NOTIFIER  LCM-320

Notifier LCM-320 Loop Control Module for NOTIFIER’s ONYX® Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.



 
HS-NCM-MF__
(4326)

NOTIFIER  HS-NCM-MF

Notifier HS-NCM High-Speed Network Communications Module. Single or Multi-mode versions available. Allow connection from Notifier Panels to NOTI•FIRE•NET™ with a fiber-optic cable or twisted-pair wire. NFPA Style 4 (Class B) or Style 7 (Class A) operation. 24 VDC, 100Mb baud transmission rate. UL, ULC, CSFM and FM approved.

CPU2-3030D
(6931)

NOTIFIER  CPU2-3030D

Notifier CPU2-3030D Central processing unit for an NFS2-3030 system. Keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control keypad. Requires an AMPS-24(E) power supply.

Page: 1 | 2 | All