Simplex Tyco 4098-9612 | Intelligent | Thermal | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

SIMPLEX TYCO   4098-9612

SKU# (6854)



SIMPLEX TYCO 4098-9612
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Simplex 4098-9612 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. 15 to 32 VDC. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

4098-9612   
Please Email us your request for quote   

Version

   4 Weeks  ]
Features Accurate and reliable heat detection for protection of property** UL listed to Standard 521 Fixed temperature operation is suitable for most applications:
  • Thermistor based design is inherently rate compensated due to minimal thermal lag
  • Available for 135° F (57° C) or 200° F (93° C)
  • UL and ULC spacing distance is 70 ft (21.3 m)
Available with rate-of-rise temperature detection:
  • Dual thermistor rate-of-rise operation
  • For use where anticipated ambient temperature changes are less than 6° F/minute (3.33° C/minute)
  • UL and ULC spacing distance is 70 ft (21.3 m)
Epoxy encapsulated electronic design provides:
  • Operation for ceiling or wall mounting
  • Easily tested, self-restoring operation with repeatable accuracy
  • Alarm indicating LED located on detector
  • Current limited alarm that is compatible with two-wire initiating device circuits (IDCs)
  • Designed for EMI compatibility
Direct connecting design:
  • Wiring attaches directly to detector terminals
  • Detector mounts onto mechanical adapter plate (supplied)

Accurate Electronic Design. Simplex electronic heat detectors use a fast response, thermistor based design to provide temperature sensing that quickly, accurately, and consistently identifies when fixed temperatures are exceeded. The fixed temperature sensing thermistor readily tracks the local ambient temperature. This eliminates the time required to melt a lead pellet or heat a bimetallic element as occurs in mechanical heat detector designs and provides the required heat detection for most applications.

Rate-of-rise detection is determined by comparing two thermistor responses. By combining accurate thermistors with proper physical placement, this patented rate-of-rise detection design achieves a high level of performance not normally available with mechanical detection.

Applications Reference

Heat detectors are used where property protection is desired and where life safety protection is not required or is performed by other equipment. Typical heat detector applications are satisfied by use of these fixed temperature electronic detectors.

The addition of rate-of-rise operation provides two forms of heat detection for use where temperature fluctuations are controlled and are less than 6° F/min (3.33° C/min). Where temperatures may fluctuate more quickly, use fixed temperature detection.

Alarm Indicating LED Operation

The heat detector LED turns ON continuously when in alarm. During normal conditions the LED is OFF.

Fixed Temperature Guidelines

135° F (57° C) fixed temperature detectors are for normal temperatures that do not exceed 100° F (38° C).

200° F (93° C) fixed temperature detectors are for normal temperatures that exceed 100° F (38° C) but are less than 150° F (66° C).

Alarm Verification Application Note

When connecting these electronic heat detectors to a 2-wire initiating device circuit (IDC) that is providing Alarm Verification for smoke detectors, use the 4098-9682, 4-wire base. The 4-wire base provides an alarm contact that is not current-limited. (Heat detectors in the 2-wire base present a current-limited alarm condition that is not compatible with Alarm Verification. Initiating devices other than smoke detectors are required to activate the alarm without starting the alarm verification cycle.)

Specifications
Voltage Range 15 to 32 VDC, filtered DC with 30% maximum ripple
Standby Current 80 A typical, 100 A maximum
Alarm Current, 2-Wire Operation Up to 86 mA maximum, exact current is determined by alarm current limiting of connected IDC
Alarm Current, 4-Wire Operation 24 mA typical @ 24 VDC
Rate-of-Rise Operation Meets FM requirements for operation between 15° and 25° F/min (8.33° and 13.88° C/min)
Humidity Range 10% to 95% RH, not intended for outdoor applications
Storage Temperature 0° to 140° F (-18° C to 60° C)
Color Frost-White
Ambient Temperature Operating Range
135° F Models 32° to 100° F (0° to 38° C)
200° F Models 32° to 150° F (0° to 68° C)

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> INTELLIGENT :    24 Items found.
GNExH1N01AB1E1RN
(7280)

E2S  GNExH1N01AB1E1RN

E2S GNExH1 Heat Detector for harshest of environments. Robust corrosion proof GRP termination enclosure. Class I Zone 1, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

D2xH1VN01AB1E1RN
(7279)

E2S  D2xH1VN01AB1E1RN

E2S D2xH1 Heat Detector for harshest of environments. Stainless steel casing and hermetically sealed contacts. Class I Zone 2 and Zone 22, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

D1xH1N01MB1A1RN
(7278)

E2S  D1xH1N01MB1A1RN

E2S D1xH1 Heat Detector for harshest of environments. Stainless steel casing and hermetically sealed contacts. Certified for Zone 1 & Zone 21, Class I Zone 1 & Zone 21, Class I/Class II Div 1 & Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

OSI-R-SS
(7244)

NOTIFIER  OSI-R-SS

Notifier OSI-R-SS Reflective Imaging Beam Smoke Detector. Includes standby, fault and alarm LED indicators. 10.2 to 32 VDC. UL, ULC and FM Approved.



 
H365
(7239)

NOTIFIER  H365

Notifier H365 Addressable Intelligent Heat Detector. Two-wire SLC loop connection. Fire-resistant plastic enclosure. 15-32 VDC. UL, FM and CSFM listed.



 
SD365
(7235)

NOTIFIER  SD365

Notifier SD365 Addressable Photoelectric Smoke Detector. Two-wire SLC loop connection. LiteSpeed and CLIP protocol. UL/ULC and FM Approved.



 
STExH1N01AS1A1RN
(7281)

E2S  STExH1N01AS1A1RN

E2S STExH1 Heat Detector for harshest of environments. Explosion proof stainless steel enclosure. Zone 1 & Zone 21, Class I Zone 1 & Zone 21, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

B110LP
(7064)

NOTIFIER  B110LP

Notifier B110LP Plug-in Smoke Detector with photoelectric sensor for a wide range of combustion sources. Includes Low current draw, built-in tamper resistant base design, remote LED option, removable cover and built-in test switch. UL, ULC, FM and MEA approved.

5601P
(4021)

NOTIFIER  5601P

Notifier System Sensor Mechanical Heat Detector

4098-9733
(6852)

SIMPLEX TYCO  4098-9733

Simplex Tyco 4098-9733 TrueAlarm Analog Heat Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

4098-9714
(6845)

SIMPLEX TYCO  4098-9714

Simplex Tyco 4098-9714 TrueAlarm Analog SSD Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

4098-9754
(6847)

SIMPLEX TYCO  4098-9754

Simplex Tyco 4098-9754 TrueAlarm Multi-Point Analog Photoelectric and Thermistor Sensor for Early Fire Detection (smoke and thermal activity). IDNet communication. Ceiling or wall mounting. UL, ULC, CSFM and FM Approved.

FST-951
(3228)

NOTIFIER  FST-951

Notifier FST-951 Series Intelligent Addressable Thermal (Heat) Detector with FlashScan and CLIP protocol systems. Two-wire SLC connection and 360° viewing angle. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FST-851 ***

4098-9401
(6846)

SIMPLEX TYCO  4098-9401

Simplex Tyco 4098-9401 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

2W_-B
(6927)

NOTIFIER  2W-B

NOTIFIER by Honeywell i3 Series Photoelectric and Thermal Smoke Detector. Wide angle and dual color LED indicator. Mounting base included. UL, FM, and CSFM Approved.

FSP-951
(2038)

NOTIFIER  FSP-951

NOTIFIER by Honeywell FSP-951 Series Intelligent Plug-in Photoelectric Smoke Detector (0.5% to 4% per foot obscuration) with FlashScan and CLIP communication protocol systems. Addressable-analog communication. Optional relay, isolator and sounder bases. UL, ULC, FM and CSFM Approvals. *** Replaces FSP-851 ***

4098-9601
(7076)

SIMPLEX TYCO  4098-9601

Simplex Tyco 4098-9601 TrueAlarm Photoelectric Intelligent Smoke Detector. 2.8%/ft or 3.5%/ft nominal sensivity. 2-wire or 4-wire operation. Ceiling or wall mounting. Includes alarm relay output and multi-function incator LED. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

4098-9757
(7073)

SIMPLEX TYCO  4098-9757

Simplex Tyco 4098-9757 QuickConnect2 TrueAlarm Analog Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet communications. Ceiling or wall mounting. NEMA 1. UL Approved.

FPTI-951
(6825)

NOTIFIER  FPTI-951

NOTIFIER by Honeywell FPTI-951 Multi-Criteria Photo/Thermal/Infrared Detector with FlashScan and CLIP protocol systems. Dual LEDs for 360° visibility. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FAPT-851 ***

DNR
(6866)

NOTIFIER  DNR

Notifier DNR intelligent Photoelectric Duct Smoke Detector for mounting to round or rectangular ducts. Non-Relay. Optional NEMA-4 watertight enclosure. Air velocity rating from 100 ft/min to 4,000 ft/min. Remote testing capability. UL, ULC, CSFM and FM approved.