Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
SKU# (6157)

DELPHIAN  364-455-01-365-251-11

DETECTORS / GAS DETECTORS
OXYGEN

$681.60     Availability: 2 Days
 Info/Quote Request
 Shipping Rates
 Volume discount



DELPHIAN 364-455-01-365-251-11 (1)
  • Overview
  • Features
  • Specs
  • Literature

Delphian GazTell Fixed Point Electrochemical Gas Detector for Oxygen (O2) 0-21% vol. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Part# with Options:        364-455-01-365-251-11
Price with Options:        681.60

Options:    

Remote Display
(1) External Display Module for Delphian Gaz Tell IR/EC via RS-485
Alarm Relays
(2) Simple Local Alarm Module for Delphian Gaz Tell IR
Communications Module
(3) Communications Module for Delphian Gaz Tell IR and Determinator
Mounting Options
(4) Mounting Options for Delphian GazTell Electrochemical
Sensor Adaptors
(5) Adaptors for Delphian GazTell Electrochemical
Splash Guard
(6) Splash Guard for Delphian GazTell

  Availability 2 Days  ]

Hassle free safety:
  • Simple to use and install
  • Shock & vibration resistant
  • Low power consumption
  • Checks itself every second
  • Plain English displays
  • Tough
  • Reliable
  • Affordable
  • Accurate
THE DETECTOR HEAD

The GazTell detector head for electrochemical cells can be used alone or with the optional modules.

  • The small size (5”L x 2”W) makes it inconspicuous and allows placement in tight areas.
  • User-friendly, alpha-numeric LED display with understandable instructions and prompts.
  • Automatically recognizes the sensor cell with no configuration necessary.
  • Scrolls gas type every few seconds.
  • Low maintenance and low cost of ownership. The detector head logs and will display the last time it was calibrated.
  • Connects directly to conduit eliminating the need for expensive and bulky junction boxes.
  • Smart Sensor saves operator time and money. The sensor knows the highest reading since last calibration, the number of days since last calibration, how long the detector head has been in service, the percentage of life remaining in the sensor and highest/lowest temperatures observed during operation. It checks itself and its vital functions continuously.
  • Power consumption is very low. Even at its maximum power consumption (with the display at its brightest), the detector head uses only 77mA @ 24VDC.
OPTIONAL SLAM
Remote Relay Module
  • Set alarm levels without software, using simple jumper selection.
  • The module can be placed anywhere relays are needed.
  • Flexible design allows the relays to be placed next to the functions they operate.
  • The relay module has robust relays rated at 6 amp@120 volt relays for Fail, Low and High Alarms, so auxiliary relays are often not needed. Alarm relays can be latching or non-latching, energized or de-energized, normally open or closed. A 5 second alarm delay can be turned on to avoid false alarms.
  • FM Approvals tested the SLAM module for operation at -4 oF to 140 oF (-20 oC to +60 oC).
OPTIONAL EXMO
Remote Display Module

The EXMO communicates directly with the detector head and mimics its display. If the detector head is located remotely high or low, or in a difficult-to-calibrate place, locating the EXMO in an accessible position gives immediate access to the detector head’s sensor. It displays everything the detector head displays. It gives control via bi-directional RS-485 communication.

Remote calibration has never been so easy.

The small extension module has the same alpha numeric LED displays and color coded operation as the remotely placed detector head.

  • Check the sensor before entering a dangerous area.
  • Take the sensor online or offline
  • Calibrate
  • Cancel calibration

SPECIFICATIONS
DimensionsDetector Head: 5"L x 2"W
EXMO, SLAM & COMO: (each) 6"L x 3.5"W x 2"H
Shipping Weight Detector Head: .875 lbs (.4 kg)
EXMO, SLAM & COMO: (each) 1.25 lbs (.6 kg)
Power: Detector Head: 77 mA max
EXMO: 16mA max
SLAM: 56 mA max
COMO: 35 mA max
Operating Voltage Nominally 12-42 VDC
Output Signal Range 4-20mA or 1-5 mA (user selectable, 4 - 20mA is default). Modbus RTU available as an option.
Output is linear and proportional to the gas scale.
Load (maximum resistance) 300 Ohms
Measurement Ranges ppm according to toxic gas electrochemical cell and % by volume for oxygen.
Temperature Range Cell Storage: +32 oF (0 oC) to +68 oF (+20 oC)
The detector head: (depending upon cell installed)
-20 oC (-4 oF) to +70 oC (+158 oF)
The EXMO/SLAM/COMO:
-20 oC (-4 oF) to +60 oC (+140 oF)
Pressure The operating pressure range for toxic cells is normally ambient +/-10%
Mean Time Between Failures (MTBF@70F) 8 years (electronics)
SLAM Relays 6 amps@120 volts
SLAM Response Time Less than a second from the time the detector head sees sufficient gas to trigger an alarm to the relay operating.
EXMO Response Time Less than a second from the time the detector head sees gas to the EXMO displaying that gas concentration.
Detector Head RFI/EMI Immunity Less than 1% of full scale change with 5w transceiver keyed within three feet. RFI/EMI Protection complies with EN50270, EN61000-6-4, ISA/IEC 6001-4-3
Area Hazard Classification: Class I, Divisions 1 & 2, Groups C, D
SIL (Safety Integrity Level) SIL 2
Warranty Detector Head, SLAM, EXMO and COMO: two years from date of shipment.
Cell: one year from date of shipment.
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal

> OXYGEN :    42 Items found.
M014-0003-000
(6334)

MPOWER  M014-0003-000

mPower UNI 321 Disposable Single Gas Detector for detection of Oxygen (O2) 0.1%-30%. Up to 36 months of live. Large LCD display will show time remaining or low/high alarm levels when hit, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$100.80 
BWC2-X
(4267)

BW  BWC2-X

BW Clip portable gas detector 2 year maintenance free for Oxygen O2. Low alarm set at 19.5%, High alarm set 23.5%. UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.



$101.92 
M001-0032-000
(6005)

MPOWER  M001-0032-000

mPower UNI MP100 Portable Single Gas Detector for detection of Oxygen (O2) 0-25% or 0-30% vol. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$169.20 
BWC2R-X
(5151)

BW  BWC2R-X

BW Clip Real Time portable gas detector with 2 year maintenance free for Oxygen (O2). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

Configure

$196.35 
10092523
(2650)

MSA  10092523

MSA ALTAIR Portable Single-gas Detector for Oxygen, alarms at 19.5% Vol. and 23% Vol. (O2) coupled with LED/audible/vibrating alarms. IP67. Superior dust/water protection, high RFI resistance and one-button operation. Available Certifications: Class 1, Division 1, Groups A, B, C and D. 2 years.



$281.86 
BTN-6544
(6761)

PROSENSE  BTN-6544

Prosense BTN-6544 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25% vol. ABS plastic housing. 2 Alarms and 1 Fault Relays and optional Modbus RS485 RTU output. IP54.

Configure

$292.50 
PC3-6524
(6806)

PROSENSE  PC3-6524

Prosense PC3-6524 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25% vol. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$324.00 
BWS_-XL-Y
(6392)

BW  BWS-XL-Y

BW Solo Serviceable Single-gas Detector for Oxygen (O2) 0-30% v/v. Small and lightweight. One button operation. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

Configure

$327.25 
G02-BE10-100
(3015)

RAE  G02-BE10-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Oxygen (O2) 0-30% vol. with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$411.06 
10074137
(1638)

MSA  10074137

MSA ALTAIR Pro Portable Single-gas Detector for Oxygen (O2) 0-25% Vol. coupled with LED/audible/flashing/vibrating alarms and with clear, backlit LCD displays. IP67. Superior dust/water protection, high RFI resistance and one-button operation. Available Certifications: Class I, Div. 1, Groups A, B, C and D; Class II,Div. 1, Group G. Alarms: Low 19.50%, High 23.00%



$466.40 
SPSTAXO2
(1476)

HONEYWELL  SPSTAXO2

Honeywell Zareba Sensepoint Gas Detector Transmitter for Oxygen (O2) 0-25% VOL complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. *** Replaces SPSTAXO1 ***

Configure

$478.09 
6302-0003
(6232)

BACHARACH  6302-0003

Bacharach MGS-410 Gas Detector Transmitter with electrochemical sensor for Oxygen (O2) 0-30 Vol% measurement in Refrigeration Applications. RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.



$479.70 
OX-6
(4089)

MACURCO  OX-6

MACURCO OX-6 low voltage Gas Detector, Controller and Transducer for Oxygen (O2) 0-25% vol. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$483.29 
P-6534
(6781)

PROSENSE  P-6534

Prosense P-6534 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25% vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$495.00 
OX-12
(4090)

MACURCO  OX-12

MACURCO OX-12 line voltage Gas Detector, controller and transducer for Oxygen (O2) 0-25% vol. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$495.08 
6302-1003
(6242)

BACHARACH  6302-1003

Bacharach MGS-450 Gas Detector Transmitter with electrochemical sensor for Oxygen (O2) 0-30 Vol% measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP41 or IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.

Configure

$536.40 
6302-4003
(6252)

BACHARACH  6302-4003

Bacharach MGS-460 Gas Detector Transmitter with remote (5m) electrochemical sensor for Oxygen (O2) 0-30 Vol% measurement in Refrigeration Applications. 3 x relays (low, high & fault), analog output (4 to 20 mA, 0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V), RS485 MODBUS RTU output, included audible & visual alarms: 72dB @10cm buzzer and single tri-color LED (green, red, orange). IP66 Housing. CE, UL and CSA Approvals. Mobile App Bluetooth Interface.



$659.70 
XT-X000-Y-NA
(578)

BW  XT-X000-Y-NA

GasAlertMax XT 4-Gas Detector for O2 (Oxygen). Monitors up to 4 gas hazards for confined space entry and remote sampling.

Configure

$698.32 
PQD-6534
(6742)

PROSENSE  PQD-6534

Prosense PQD-6534 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25%. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$702.00 
SPC3-1195-200US
(2909)

INTEC  SPC3-1195-200US

Intec Controls PolyGard SPC3-1195 Sigle-Point Gas Detector for Oxygen (O2) 0-25% Vol, 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified.

Configure

$704.40 