Prosense P-6534 | Oxygen | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

PROSENSE   P-6534

PROSENSE P-6534
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Prosense P-6534 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25% vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

P-6534   
540.54

Relays
IP66 Adaptor
No calibration port

   3 Weeks  ]
Trustworthy Certification

PROSENSE "P" Series fixed gas detectors are certified with ATEX/IECEx.

Ex-proof Safety

The continuous measurement of toxic and explosive gases is done safely in hazardous areas thanks to the ex-proof housing.

Robust and Durable

SS316 stainless steel sensor head performs perfectly under harsh environmental conditions with the IP65 protection class.

Accurate Readings

Pellistor, Electrochemical, and Infrared sensors undoubtedly provide an accurate and sensitive measurement.

Ready to Operate

4-20mA Analog and Modbus RS485 RTU outputs are provided onboard to operate properly without any additional setup.

Easy Maintenance

P Series detectors allow sensor replacement with pre-calibrated sensor head thanks to the Procell technology.

Automatic Calibration

Detector calibration can be done automatically via preset values recorded in detector software once calibration requirements are provided.

Pellistor-Saver Mode

Detectors power off sensor in high gas concentration in order to properly secure the operational lifetime of Pellistor sensor.

Auto Analog Signal Monitoring

P Series detectors carefully check the analog output signal level continuously to match the measurement level before promptly transferred to the panel. P Series adjust the signal level in case of any deviation and generate fault signal when adjustment fails.

Universal Communication Protocols

  • 4-20mA Analog and Modbus RS485 RTU outputs are simple to operate efficiently.
  • P Series open-source Modbus codes support successful integration to SCADA systems.
  • P-3R+ relay module can be properly integrated into P Series detectors for extra operations.

Zero Suppression

Adjusting, the detector will show a certain measurement level as 0 (zero) to avoid unnecessary concerns.

Fail-Safe Technology Alarming

Alarm 1 and Alarm 2 relays are easy to set to default LEL, ppm, VOL levels. The fault relay output properly indicates fault status.

Continuous Self-Test

The detectors check itself continuously if it operates perfectly or not and indicates a fault in case of any failure.

Maintenance via Software

Prosense provides software to maintain your active system easily and calibrate the gas detectors properly via computer.

Applications
  • Process Industry
  • Water Treatment
  • Chemical Industry
  • Food and Medicine Facilities
  • Metal Industry
  • Gas Distribution Stations
  • Laboratories

Specifications P-XY34
Sensor Technology Electrochemical
Output Signal 44-20mA and Modbus RS485 RTU
Sensor Warm-Up Time 60sec
Response Time(T90) <30sec*
Accuracy %ą1
Operating Temperature -40°C ~ +70°C
Humidity 5 ~ 95%RH
Input Min 10VDC - Max 32VDC - Nominal 24VDC
Power Consumption Max. 4W
Optional Relay Outputs 2 Alarms (Selectable) and 1 Fault (All relays are NO/NC adjustable)
Cable Entry 2 x 1/2''NPT
IP Rating IP65 / Optional IP66 (Sensor Head)
Junction Box Epoxy Painted Die-Cast Aluminum
Sensor Head 316L Stainless Steel
Dimensions/Weight 183x118,15x88mm / 1420gr
ATEX Marking II 2G Ex db IIC T5/T4 Gb
Hazardous Class Zone 1 or Zone 2
Certificates IMQ 19 ATEX 045 X
IECEx IMQ 18.0009X
Standards IEC EN 60079-0
IEC EN 60079-1
IEC EN 60079-18
Warranty 12 months from date of shipment from Prosense Technology
Export Info
Made inTurkey
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    17 Items found.
PR-KT12
(6978)

PROSENSE  PR-KT12

Prosense 1/2" NPT ATEX Certified Blind Plug for P, PQ and B Series gas detectors



$12.28 
PR-NYY12
(6976)

PROSENSE  PR-NYY12

Prosense 1/2"NPT ATEX Certified Cable Gland for P, PQ and B Series gas detectors



$18.41 
CG2-X-18.0-34
(2114)

BW  CG2-X-18.0-34

BW Calibration Gas mixture Oxygen O2 (18.0%), Nitrogen Balance, 34L steel cylinder.

BW-CG2X18034-EQUIV
(2211)

PORTAGAS  BW-CG2X18034-EQUIV

Calibration Gas Oxygen 18% Balance Nitrogen Size 34 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

PK-K30T
(6768)

PROSENSE  PK-K30T

Prosense Teflon Calibration cup/cap for P, PE, PQ and B Series gas detectors, tubing entry 4mm diameter tubing. Optional SS316

Configure

$100.98 
CYL-90092356
(874)

PORTAGAS  CYL-90092356

Calibration Gas Oxygen (O2) 20.8% vol. Balance Nitrogen, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$125.21 
CYL-90096071
(873)

PORTAGAS  CYL-90096071

Calibration Gas Oxygen (O2) 18% Balance Nitrogen, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$125.21 
MSA-479857-EQUIV
(2369)

PORTAGAS  MSA-479857-EQUIV

Calibration Gas Oxygen 20.8% Balance Nitrogen Size 100 Liter GAL C-10 Inlet Cylinder (Made by Portagas) (No RFID neck ring)

Configure

$125.21 
CYL-90095247
(1303)

PORTAGAS  CYL-90095247

Calibration Gas Oxygen (O2) 19% vol. Balance Nitrogen, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$125.21 
PROX-EDU
(7017)

PROSENSE  PROX-EDU

Prosense PDM Software 1-Year license for maintenance, setup, calibration, monitoring and troubleshooting of PQ, P, PC3 series gas detectors. Calibration function is licensed separately, to print calibration reports or certificates directly from the program after calibration.

Configure

$165.00 
P-ASU-2
(6989)

PROSENSE  P-ASU-2

Prosense flow adapter cell for SH30 and SH20 sensor heads used in PQ, P, PE and PC3 series, gas sampling applications. For 6mm OD Tubing made of corrosion-resistant Teflon.



$405.90 
SP-P-TB04
(7037)

PROSENSE  SP-P-TB04

Prosense P Transmitter/Main Board for P series gas detectors



$462.00 
1200-0528
(3135)

GDS  1200-0528

GDS Gas Detector Calibration Gas Kit Oxygen (O2) 18%. Balance Nitrogen. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

S-DP4
(6764)

PROSENSE  S-DP4

Prosense S-DP4 Gas Detector Controller, Alarm Panel for Up to 4 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

$772.20 
S-DP8
(6765)

PROSENSE  S-DP8

Prosense S-DP8 Gas Detector Controller, Alarm Panel for Up to 8 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

$900.90 
S-DPX064
(7034)

PROSENSE  S-DPX064

Prosense S-DPX064 Gas Detector Controller, Alarm Panel for 64 x RS485 MODBUS RTU Detectors + 8 x 4-20mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

$1,801.80 
S-DPX128
(7035)

PROSENSE  S-DPX128

Prosense S-DPX128 Gas Detector Controller, Alarm Panel for 128 x RS485 MODBUS RTU Detectors + 8 x 4-20mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

$2,316.60 
> OXYGEN :    29 Items found.
BWC2-X
(4267)

BW  BWC2-X

BW Clip portable gas detector 2 year maintenance free for Oxygen O2. Low alarm set at 19.5%, High alarm set 23.5%. UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.



 
M001-0032-000
(6005)

MPOWER  M001-0032-000

mPower UNI MP100 Portable Single Gas Detector for detection of Oxygen (O2) 0-25% or 0-30% vol. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$150.40 
BWC2R-X
(5151)

BW  BWC2R-X

BW Clip Real Time portable gas detector with 2 year maintenance free for Oxygen (O2). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

BWS1-XL-Y
(6392)

BW  BWS1-XL-Y

BW Solo Serviceable Single-gas Detector for Oxygen (O2) 0-30% v/v. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PC3-6524
(6806)

PROSENSE  PC3-6524

Prosense PC3-6524 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25% vol. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$463.32 
OX-6
(4089)

MACURCO  OX-6

MACURCO OX-6 low voltage Gas Detector, Controller and Transducer for Oxygen (O2) 0-25% vol. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$481.90 
OX-12
(4090)

MACURCO  OX-12

MACURCO OX-12 line voltage Gas Detector, controller and transducer for Oxygen (O2) 0-25% vol. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$494.01 
SPSTAXO2
(1476)

HONEYWELL  SPSTAXO2

Honeywell Zareba Sensepoint Gas Detector Transmitter for Oxygen (O2) 0-25% VOL complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. *** Replaces SPSTAXO1 ***

Configure

$648.84 
364-455-01-365-251-11
(6157)

DELPHIAN  364-455-01-365-251-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Oxygen (O2) 0-21% vol. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PQN-6534-1/2
(6954)

PROSENSE  PQN-6534-1/2

Prosense PQN-6534 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25%. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$720.72 
XT-X000-Y-NA
(578)

BW  XT-X000-Y-NA

GasAlertMax XT 4-Gas Detector for O2 (Oxygen). Monitors up to 4 gas hazards for confined space entry and remote sampling.

PQD-6534-1/2
(6742)

PROSENSE  PQD-6534-1/2

Prosense PQD-6534 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25%. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$875.16 
GG-O2-C0
(2968)

CALIBRATION TECHNOLOGIES  GG-O2-C0

CTI GasGuard O2 Oxygen Electrochemical Sensor (15-25% or 0-25%) for gas leak detection in food air quality monitoring, refrigeration systems, confined space and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,088.34 
2106B1430
(1468)

HONEYWELL  2106B1430

Honeywell Sieger Sensepoint Gas Detector Transmitter for Oxygen (O2) 25% V/V with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
1100ALD-109010/30P-L0
(6916)

RC SYSTEMS  1100ALD-109010/30P-L0

RC Systems SenSmart 1100 gas detector for Oxygen (O2) 0-25% with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,314.28 
SPXCDULNO1
(662)

HONEYWELL  SPXCDULNO1

Honeywell XCD Sensepoint Gas Detector, Oxygen (O2) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for oxygen (O2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 25%Vol. only UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,379.12 
100-0008-SS/100-0015-O2
(4760)

ESP SAFETY  100-0008-SS/100-0015-O2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Oxygen (O2) 0-30% vol. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
S3KUL2-XNXXSO1SS
(682)

HONEYWELL  S3KUL2-XNXXSO1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring OXYGEN (O2) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-25%VOL Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,497.56 
41001AL-0-1026/0030P/L0
(7177)

RC SYSTEMS  41001AL-0-1026/0030P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Sulfur Dioxide (SO2) 0-10ppm to 0-500ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
41001AL-0-1010/0025P/L0
(7176)

RC SYSTEMS  41001AL-0-1010/0025P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Oxygen (O2) 0-25% vol with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 