Simplex Tyco 4098-9754 | Intelligent | Smoke | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

SIMPLEX TYCO   4098-9754

SKU# (6847)



SIMPLEX TYCO 4098-9754
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Simplex Tyco 4098-9754 TrueAlarm Multi-Point Analog Photoelectric and Thermistor Sensor for Early Fire Detection (smoke and thermal activity). IDNet communication. Ceiling or wall mounting. UL, ULC, CSFM and FM Approved.

UL   FM

4098-9754   
Please Email us your request for quote   

Version
Bases

   4 Weeks  ]
2 Variants of base SKU
Features TrueAlarm photoelectric smoke sensing and heat sensing combined in one housing to provide:
  • Smoke activity accurately monitored by TrueAlarm photoelectric sensing technology
  • Thermal activity accurately monitored by TrueAlarm thermistor sensing technology
  • And TrueSense detection, a correlation of smoke activity and thermal activity providing intelligent fire detection earlier than with either activity alone
For use with Simplex ® 4007ES, 4010ES, 4100ES, and 4100U fire alarm control panels:
  • TrueAlarm analog sensor information is digitally communicated to the control panel via IDNet two-wire communications
  • Special point types allow the 4098-9754 multi-sensor to communicate smoke and heat analog sensing data using only one IDNet address
  • Individual sensor information is processed by the host control panel to determine sensor status and to determine whether conditions are normal, off-normal, or alarm
  • (4100U fire alarm control panels require software revision 11 or higher with multi-point compatible IDNet transmission modules)
Alarms can be determined by either:
  • Smoke detection with selectable sensitivity from 0.2 to 3.7 %/ft obscuration (refer to additional information on page 2)
  • Heat detection selectable as fixed temperature or fixed with selectable rate-of-rise
  • TrueSense intelligent analysis of the combination of smoke and heat activity
Additional design features:
  • Functional and architecturally styled enclosures for ceiling or wall mounting
  • Smoke sensor louver design that directs air flow to chamber enhancing smoke capture
  • Built-in magnetic test feature
  • Compatible with standard bases (including relay control), sounder bases, and isolator bases
  • Designed for EMI compatibility
TrueAlarm Multi-Sensor Description

TrueAlarm multi-sensor model 4098-9754 combine the established performances of a TrueAlarm photoelectric smoke sensor with a fast-acting and accurate TrueAlarm thermal sensor to provide both features in a single sensor/base assembly.

Digital Communication of Analog Sensing. Analog information from each sensor is digitally communicated to the control panel where it is analyzed. Photoelectric sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor’s present value against its average value. Thermal data is processed to look for absolute or rate-of-rise temperature as desired.

Intelligent Data Evaluation. Monitoring each photoelectric sensor’s average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Status indications of dirty and excessively dirty are automatically generated allowing maintenance to be performed per device.

Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the control panel, selectable as more or less sensitive as the individual application requires.

Multi-Point Reporting and CO Base Reference. Reporting 4098-9754 “sub-points” under its single address varies with the base used. Muti-point details are listed in data sheet S4090-0011. Using the 4098-9754 with CO sensor bases is detailed in data sheet S4098-0052.

Timed/Multi-Stage Selection. Alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm.

Sensor Alarm and Trouble LED Indication. Each sensor base’s LED pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base’s LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors.

TrueAlarm Analog Sensor Features General mechanical:
  • Housing is sealed against rear air flow entry
  • Electronics are EMI/RFI shielded
Smoke sensing:
  • Photoelectric light scattering sensing technology
  • 360° smoke entry for optimum response
  • Chamber screen provides protection from dirt, dust, and insects
Heat sensing:
  • Fast response thermistor design
  • Rate compensated, self-resetting operation
  • Control panel can select per sensor for fixed temperature sensing, rate-of-rise temperature sensing, or the combination of both
Photoelectric Sensing Details

TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, 3.0%, and 3.7%. Application type and sensitivity are selected and then monitored at the fire alarm control panel.*

Sensor head design provides 360° smoke entry for optimum smoke response. Because of the photoelectric sensing technology, the 4098-9754 sensor is UL listed for air velocity of up to 4000 ft/min. However, care must be taken in determining sensor locations to avoid areas where local airflow may also impact any smoke flow. (Refer to the application reference section on this page.)

Heat Sensing Details

TrueAlarm heat sensors monitor a fast reacting thermistor providing operation that is self-restoring and rate compensated. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. The control panel allows alarm selection to be per sensor as fixed temperature, or rate-of-rise temperature, or the combination of both.

Temperature Detection. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and selectable to operate at 135° F (57.2° C) or 155° F (68° C). In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its selected fixed temperature setting.

Utility Temperature Monitoring. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 122° F (0° C to 50° C). This feature can provide freeze warnings or alert to HVAC system problems.

TrueSense Detection Details

Control Panel Sensor Analysis. Each multi-sensor’s smoke and heat sensing element provides data for evaluation at the fire alarm control panel where four independent detection modes are evaluated. They are:

  • Fixed temperature heat detection
  • Rate-of-rise heat detection
  • TrueAlarm photoelectric smoke detection
  • And TrueSense correlation detection

Comparing Photoelectric Activity and Thermal Activity. TrueSense analysis correlates both thermal activity and smoke activity at a single multi-sensor location using an extensively tested covariance relationship. As a result, TrueSense detection improves response to conditions indicative of faster acting, hot flaming fires when compared to the response of either photoelectric smoke activity or thermal activity alone.

High Integrity Detection. TrueSense operation provides early fire detection and maintains the established high level of immunity to false alarms and nuisance alarms that is inherent with TrueAlarm sensor operation.

Application Reference

Sensor locations should be determined after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.*

Multi-Sensor Base Features

Base mounted address selection allows the address of the multi-sensor base to remain with its programmed location when the sensor is removed for service.

Integral red LED indicates power-on by pulsing, or alarm or trouble when steady on, reflecting status of either sensor. The exact status of the specific sensing element is annunciated at the fire alarm control panel.

Fire Alarm Control Panel Features
  • Individual smoke sensitivity and temperature operation is selectable for each sensor
  • Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements
  • Peak value logging allows accurate analysis for sensitivity selection
  • Automatic, once per minute individual sensor calibration check verifies sensor integrity
  • Multi-stage alarm operation
  • Selectable alarm verification
  • Automatic environmental compensation and determination of dirty and excessively dirty
  • TrueSense analysis of smoke and heat activity
  • Ability to display and print detailed sensor information in plain English language
  • Smoke sensitivity displayed in percent per foot and temperature readings selectable as Fahrenheit or Celsius

General Operating Specifications
Communications and Sensor Supervisory PowerIDNet communications, 1 address per base
UL Listed Operating Temperature Range32° F to 100° F (0° C to 38° C)
Operating Temperature Range15° F to 122° F (-9° C to 50° C)
Storage Temperature Range0° F to 140° F (-18° C to 60° C)
Humidity Range10 to 95% RH
Smoke Sensor Sensitivity Range0.2 % to 3.7% per foot of smoke obscuration, selected at control panel (refer to additional information on page 2)
Smoke Sensor Air Velocity Range0-4000 ft/min (0-1220 m/min)
Thermal Sensor Operation (selected at control panel)Fixed alarm temperature setting of 135° F (57.2° C), and/or rate-of-rise temperature alarm at 15°F (8.3° C) or 20° F (11.1° C), also selectable as utility monitoring operation from 32° F to 122° F (0° C to 50° C)
Housing ColorFrost White or Black
Export Info
Made inMexico
Harmonized Tariff Code (HTC)85311001

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> INTELLIGENT :    24 Items found.
GNExH1N01AB1E1RN
(7280)

E2S  GNExH1N01AB1E1RN

E2S GNExH1 Heat Detector for harshest of environments. Robust corrosion proof GRP termination enclosure. Class I Zone 1, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

D2xH1VN01AB1E1RN
(7279)

E2S  D2xH1VN01AB1E1RN

E2S D2xH1 Heat Detector for harshest of environments. Stainless steel casing and hermetically sealed contacts. Class I Zone 2 and Zone 22, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

D1xH1N01MB1A1RN
(7278)

E2S  D1xH1N01MB1A1RN

E2S D1xH1 Heat Detector for harshest of environments. Stainless steel casing and hermetically sealed contacts. Certified for Zone 1 & Zone 21, Class I Zone 1 & Zone 21, Class I/Class II Div 1 & Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

OSI-R-SS
(7244)

NOTIFIER  OSI-R-SS

Notifier OSI-R-SS Reflective Imaging Beam Smoke Detector. Includes standby, fault and alarm LED indicators. 10.2 to 32 VDC. UL, ULC and FM Approved.



 
H365
(7239)

NOTIFIER  H365

Notifier H365 Addressable Intelligent Heat Detector. Two-wire SLC loop connection. Fire-resistant plastic enclosure. 15-32 VDC. UL, FM and CSFM listed.



 
SD365
(7235)

NOTIFIER  SD365

Notifier SD365 Addressable Photoelectric Smoke Detector. Two-wire SLC loop connection. LiteSpeed and CLIP protocol. UL/ULC and FM Approved.



 
STExH1N01AS1A1RN
(7281)

E2S  STExH1N01AS1A1RN

E2S STExH1 Heat Detector for harshest of environments. Explosion proof stainless steel enclosure. Zone 1 & Zone 21, Class I Zone 1 & Zone 21, Class I/Class II Div 2. IECEx, ATEX, UL, ULC and cUL approvals. IP66/IP67.

B110LP
(7064)

NOTIFIER  B110LP

Notifier B110LP Plug-in Smoke Detector with photoelectric sensor for a wide range of combustion sources. Includes Low current draw, built-in tamper resistant base design, remote LED option, removable cover and built-in test switch. UL, ULC, FM and MEA approved.

5601P
(4021)

NOTIFIER  5601P

Notifier System Sensor Mechanical Heat Detector

4098-9733
(6852)

SIMPLEX TYCO  4098-9733

Simplex Tyco 4098-9733 TrueAlarm Analog Heat Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

4098-9612
(6854)

SIMPLEX TYCO  4098-9612

Simplex 4098-9612 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. 15 to 32 VDC. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

4098-9714
(6845)

SIMPLEX TYCO  4098-9714

Simplex Tyco 4098-9714 TrueAlarm Analog SSD Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

FST-951
(3228)

NOTIFIER  FST-951

Notifier FST-951 Series Intelligent Addressable Thermal (Heat) Detector with FlashScan and CLIP protocol systems. Two-wire SLC connection and 360° viewing angle. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FST-851 ***

4098-9401
(6846)

SIMPLEX TYCO  4098-9401

Simplex Tyco 4098-9401 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

2W_-B
(6927)

NOTIFIER  2W-B

NOTIFIER by Honeywell i3 Series Photoelectric and Thermal Smoke Detector. Wide angle and dual color LED indicator. Mounting base included. UL, FM, and CSFM Approved.

FSP-951
(2038)

NOTIFIER  FSP-951

NOTIFIER by Honeywell FSP-951 Series Intelligent Plug-in Photoelectric Smoke Detector (0.5% to 4% per foot obscuration) with FlashScan and CLIP communication protocol systems. Addressable-analog communication. Optional relay, isolator and sounder bases. UL, ULC, FM and CSFM Approvals. *** Replaces FSP-851 ***

4098-9601
(7076)

SIMPLEX TYCO  4098-9601

Simplex Tyco 4098-9601 TrueAlarm Photoelectric Intelligent Smoke Detector. 2.8%/ft or 3.5%/ft nominal sensivity. 2-wire or 4-wire operation. Ceiling or wall mounting. Includes alarm relay output and multi-function incator LED. 24 VDC. UL, ULC, CSFM Listed. FM Approved.

4098-9757
(7073)

SIMPLEX TYCO  4098-9757

Simplex Tyco 4098-9757 QuickConnect2 TrueAlarm Analog Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet communications. Ceiling or wall mounting. NEMA 1. UL Approved.

FPTI-951
(6825)

NOTIFIER  FPTI-951

NOTIFIER by Honeywell FPTI-951 Multi-Criteria Photo/Thermal/Infrared Detector with FlashScan and CLIP protocol systems. Dual LEDs for 360° visibility. Optional relay, isolator and sounder bases. UL/ULC Listing. FM, and CSFM Approved. *** Replaces FAPT-851 ***

DNR
(6866)

NOTIFIER  DNR

Notifier DNR intelligent Photoelectric Duct Smoke Detector for mounting to round or rectangular ducts. Non-Relay. Optional NEMA-4 watertight enclosure. Air velocity rating from 100 ft/min to 4,000 ft/min. Remote testing capability. UL, ULC, CSFM and FM approved.

FCO-951
(3502)

NOTIFIER  FCO-951

Notifier IntelliQuad PLUS FCO-951 Advanced Multi-Criteria Fire/CO Detector with four unique sensing elements: Carbon Monoxide (CO) electrochemical sensor, Infrared (IR) sensing measure, Photo-electric smoke detection and Thermal detection. UL listed. *** replaces FSC-851 ***



 
FSV-951R
(3229)

NOTIFIER  FSV-951R

Notifier FSV-951R Series Very Intelligent Plug-in Early Warning (VIEW) Laser Smoke Detector. 0.03% to 1.00% (CLIP) or 0.02% to 2.00% (other) sensivity. With FlashScan and CLIP protocol systems. Advanced laser light source and 360° viewing angle. Optional relay, isolator and sounder bases. UL and MEA listed. FM, CSFM, BSMI and CCCF Approved. (replaces FSL-751)

4098-9756
(7075)

SIMPLEX TYCO  4098-9756

Simplex Tyco 4098-9756 Addressable Duct Sensor Housing with TrueAlarm Photoelectric Smoke Sensor. Includes relay, supervised output for multiple remote relays and 2 diagnostic LEDs. IDNet and MAPNET II communications. UL listed (requires separate 24 VDC fire alarm power).



 
FS-OSI-RI
(6933)

NOTIFIER  FS-OSI-RI

Notifier FS-OSI-RI Intelligent Addressable Single-ended Reflective Imaging Beam Smoke Detector suited for large open areas with high ceilings. 24 VDC. 12° field of view. Status LED indicators. UL and FM approved.



 