Notifier Hpf24s6 | Notifier | Power Supplies | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   HPF24S6

SKU# (6601)
NOTIFIER HPF24S6
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier HPF24S6(C/E) (6 amp) or HPF24S8(C/E) (8 amp) Remote Fire Alarm Power Supply with battery charger for 12 or 24 volt fire alarm control panels (FACP). 4 configurable outputs. UL, ULC and NFPA listed. *** Phased Out Replaced by HPF-PS6***

Inquiry

The HPF24S6(C/E) and HPF24S8(C/E) are compact, cost-effective, 6-amp or 8-amp remote power supplies with battery charger.

They may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA requirements and NAC synchronization) or auxiliary power to support 24-volt system accessories. The supply provides regulated and filtered 24 VDC power to four Notification Appliance Circuits configured as either four Class B (Style Y) or Class A (Style A, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. They also contains a battery charger capable of charging up to 18 Amp Hour batteries.

FEATURES AND BENEFITS
  • Extends and supports power for additional fire alarm devices
  • Instantaneous switchover to standby battery (if equipped) when AC fails, maintaining power to all attached devices without intervention
  • Strobe signal “passes through” allowing syncing of large systems
  • LED lights for quick and easy diagnosis, troubleshooting, and status indication
  • Two outputs can be used for constant power devices such as door holders (power drops upon alarm)
  • Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notification circuit (including unfiltered and unregulated bell power)
  • UL Listed NAC Synchronization using System Sensor®, Wheelock®, or Gentex® (Commander Series) appliances
  • Cascade up to 10 power supplies (four with Gentex) with strobe timing maintained
  • Operates as a sync follower or a sync generator (default)
  • Contains two, fully-isolated input/control circuits (triggered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [standalone mode])
  • Configured to internally house addressable SLC control module for alarm activation
  • Four Class B (Style Y) or four Class A (Style Z) (with ZNAC-4 Module) Notification Appliance Circuits
  • 6.0A or 8A (depending on model) full load output (3.0 A maximum per circuit) in NAC expander mode (UL 864)
  • 4.0A or 6.0A continuous output in stand-alone mode (UL 1481)
  • In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable or a mix of two and two
  • Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power
  • Power-limiting technology meets UL power-limiting requirements
  • Form-C normally-closed trouble relay
  • Fully supervised power supply, battery and Notification Appliance Circuits
  • Selectable earth fault detection
  • AC trouble report selectable for immediate or 8 hour delay
  • Requires input trigger voltage of 9.0 - 32 VDC
  • Self-contained in compact, lockable cabinet (15" [38.1 cm] H x 14.5" [36.8 cm] W x 2.75" [7.0 cm] D)
  • Includes integral battery charger capable of charging up to 18 AH batteries; cabinet capable of housing 7.0 AH batteries
  • Battery charger may be disabled via dip switch for applications requiring larger batteries
  • Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire
  • Power-limiting technology meets UL power-limiting requirements
  • Form-C normally-closed trouble relay
  • Fully supervised power supply, battery and Notification Appliance Circuits
  • Selectable earth fault detection
  • AC trouble report selectable for immediate or 8 hour delay
  • Requires input trigger voltage of 9.0 - 32 VDC
  • Self-contained in compact, lockable cabinet (15" [38.1 cm] H x 14.5" [36.8 cm] W x 2.75" [7.0 cm] D)
  • Includes integral battery charger capable of charging up to 18 AH batteries; cabinet capable of housing 7.0 AH batteries
  • Battery charger may be disabled via dip switch for applications requiring larger batteries
  • Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire
STANDARDS AND CODES
  • NFPA 72 National Fire Alarm Code
  • UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode)
  • UL 1481 Power Supplies for Fire Alarm Systems (standalone mode)
  • CAN/ULC-S527-99
Listings

Listings and approvals below apply to the HPF24S6 and HPF24S8. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL Listed: S6677
  • CAN/ULC Listed: S6677
  • CSFM: 7315-1637:0102
  • FM Approved

Specifications
Primary (AC) Power:HPF24S6/8(C): 120 VAC 60 Hz, 3.2 A maximum
HPF24S6/8E: 220/240 VAC, 50 Hz, 1.6 A maximum
Wire size: minimum 14 AWG (2.0 mm2) with 600V insulation
Control Input Circuit:Trigger Input Voltage: 9.0 to 32 VDC
Trigger Current: 2.0 mA (16 - 32 V)
(per input) 1.0 mA (9 - 16 V)
Trouble Contact Rating:5.0 A at 24 VDC
Auxiliary Power Output:Special Application Power - 500 mA maximum
Output Circuits:+24 VDC filtered, regulated
3.0 A maximum for any one circuit
4.0 A maximum total continuous current for all outputs (Stand-alone mode) for the HPF24S6 and 6A for the HPF24S8
6A or 8A (depending on model) maximum total short-term current for all outputs (NAC Expander mode)
Secondary Power (Battery) Charging Circuit:Supports lead-acid batteries only
Float-charge voltage: 27.6 VDC
Maximum current charge: 1.5 A
Maximum Battery capacity: 18 AH
> ACCESSORIES - RELATED - CONSUMABLES :    2 Items found.
NBG-12LOB
(4603)

NOTIFIER  NBG-12LOB

Notifier NBG-12LOB Pull Station which provides a Fire Alarm Control Panel (FACP) with a single alarm input signal. Includes dual action operation, Key-Lock Reset function, outdoor-use gasket and sealed switch. UL Listed.



 
NFS-320
(2039)

NOTIFIER  NFS-320

NOTIFIER by Honeywell ONYX Series NFS-320 Intelligent Addressable Fire Alarm Control Panel. Certified for seismic and marine applications. Supports up to 159 detectors and 159 modules. Standard 80-character display and 6A power supply. Built-in Alarm, Trouble, Security and Supervisory relays, FlashScan network prototol.

> NOTIFIER :    43 Items found.
MMF-300
(7242)

NOTIFIER  MMF-300

Notifier MMF-300 Addressable Monitor Module for supervising circuits of dry-contact input devices. Powered by two-wire SLC loop. 15-32 VDC. UL and FM listed.



 
RTS151KEY
(7241)

NOTIFIER  RTS151KEY

Notifier RTS151KEY automatic remote test station for duct smoke detectors. Includes key and status indicator.



 
MMF-301
(7238)

NOTIFIER  MMF-301

Notifier MMF-301 Addressable Mini-Monitor Module for use in intelligent, two-wire using rotary switches. 15-32 VDC.



 
CRF-300
(7236)

NOTIFIER  CRF-300

Notifier CRF-300 Addressable Relay Module for activation of auxiliary devices (fans, dampers, etc). Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM and MEA Approved.



 
CMF-300
(7243)

NOTIFIER  CMF-300

Notifier CMF-300 Addressable Control Module for providing intelligent control panels a circuit for notification. 15-32 VDC. ULC listed.



 
B300-6
(7063)

NOTIFIER  B300-6

Notifier B300-6 Standard 6” Intelligent Base

SMB500-WH
(4022)

NOTIFIER  SMB500-WH

Notifier System Sensor Surface Mount Box



 
SB-10
(6935)

NOTIFIER  SB-10

Notifier SB-10 (Metal) or SB-I/O (Plastic) Surface Backbox for Notifier NBG-10 or NBG-12 pull stations.

B501-WH
(7067)

NOTIFIER  B501-WH

Notifier B501 4” standard European flangeless mounting base. UL/ULC listed.

SPCWL
(7068)

NOTIFIER  SPCWL

Notifier SPCWL Indoor Selectable-Output Speaker for Ceiling Applications (520 Hz). 12- or 24-volt operation. UL, ULC, FM and CSFM approved.



 
FMM-1
(3695)

NOTIFIER  FMM-1

Notifier FMM-1/FMM-101 Series Monitor Module for supervised dry-contact input devices or monitor and power two-wire circuits. Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and US Coast Guard Approved.

HWL-LF
(7065)

NOTIFIER  HWL-LF

Notifier HRL-LF or HWL-LF Low frequency wall sounder (520 Hz). Plastic housing. Includes universal mounting plate. NFPA compliance. UL Listed.

B200S-WH
(6928)

NOTIFIER  B200S-WH

Notifier B200S-WH Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. Only compatible with the NFS-320, NFS2-640 and NFS2-3030 operating version with version 15.0 or higher panel firmware.



 
FRM-1
(3694)

NOTIFIER  FRM-1

Notifier FRM-1 Series Relay Module for activation of auxiliary devices (fans, dampers, etc). Two-wire SLC loop. Two Form-C dry contacts. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



 
FCM-1
(3236)

NOTIFIER  FCM-1

Notifier FCM-1 Series Addressable Control Module for Notification Appliances (horns, strobes, speakers, etc). Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



 
B210LPBP
(4141)

NOTIFIER  B210LPBP

Notifier B210LPBP Flanged Mounting Intelligent Base (10 Pack)



 
FDM-1
(6597)

NOTIFIER  FDM-1

Notifier FDM-1 Series Monitor Module to supervise, monitor and power Style B dry-contact input devices with two-wire circuits. Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and US Coast Guard Approved.



 
B200S-LF-WH
(7066)

NOTIFIER  B200S-LF-WH

Notifier BS200S-LF Low Frequency Intelligent, programmable sounder base (520 Hz). Meest NFPA 72.

FCM-1-REL
(4143)

NOTIFIER  FCM-1-REL

Notifier FCM-1-REL(A) Series Releasing Control Module for fire suppresion releasing applications. Reports the panel status as NORMAL, OPEN or SHORT CIRCUIT. Analog communications. FlashScan operation. 15 to 32 VDC. UL, FM and CSFM Approved.



 
BAT-12180-BP
(4140)

NOTIFIER  BAT-12180-BP

Notifier BAT-12180-BP rechargeable battery. 12VDC. 18 AH. 2-unit bulk pack, Overcharge protected. ABS high-impact case.



 