Detcon 967-12ej90-100 | Ethylene Oxide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

DETCON   967-12EJ90-100

DETCON 967-12EJ90-100
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Detcon DM-700-C2H4O Electrochemical Smart Ethylene Oxide (C2H4O) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

967-12EJ90-100   
Please Email us your request for quote   

Junction Box
Options
Integration Modules
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2
Mounting Options
Additional Modules

   3 Weeks  ]
12 Variants of base SKU

Detcon Model 700 Series Sensors are a non-intrusive “Smart” sensors designed to detect and monitor oxygen and Toxic Gases in air using electrochemical sensor technology. The intelligent plug-in, field replaceable cell provides automatic recognition of gas type and range, and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model 700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model 700 is equipped with standard analog 4-20mA, and ModbusTM RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), HART, and Foundation Fieldbus. Detcon’s toxic gas and oxygen sensors have a long shelf life and are supported by an industry-leading warranty.

Features Failsafe User-Friendly Interface
  • LED Display (With Antiglare Cover)
  • Full Text Display Method
  • Non-intrusive Interface
  • Auto Zero/Auto Span
  • Pre-emptive Fault Diagnostics
Environmentally Bulletproof
  • Electropolished 316SS Construction
  • 100% Epoxy Encapsulated Circuitry
  • Bulletproof I/O Protection
  • Water-Proof, Corrosion-Proof, Vibration-Proof
Modular and Serviceable
  • Modular Design
  • Plug and Play Components
  • Quick Thread Release (For Sensor Replacement)
  • Integral Calibration Port
Applications
  • Oil & Gas
  • Chemical Plants
  • Food and Beverage
  • Steel Mills
  • Pulp and Paper
  • Refineries
  • Wastewater Treatment Plants
  • Utilities

System Specifications
Sensor TypeContinuous diffusion/adsorption
3-electrode electrochemical cell
Plug-in field replaceable Type
Measurement Range0-100 ppm
Accuracy/Repeatability±2% FS
Response/Clearing TimeT90≤140 seconds
OutputsLinear 4-20 mA DC
RS-485 MODBUS-RTU
Electrical ClassificationExplosion proof
CSA and US (NRTL)
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C)
Class I, Zone 1, Group IIC
ATEX
II 2 G Ex d ib IIB + H2 T4 GB
Ingress ProtectionNEMA 4X, IP66
Safety ApprovalsCCSAUS
ATEX
CE Marking
SIL2 Certified to IEC 61508
Environmental Specifications
Operating Temperature Range-4 to 122oF/-20 to 50oC
Storage Temperature Range-31 to 131oF/-35 to 55oC
Operating Humidity Range15-90% RH non-condensing
Mechanical Specifications
Dimensions7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box)
Mechanical Connection:
Mounting holes (J-box) 5.5"; 140mm center to center
Weight2 lbs; 0.907kg (sensor only)
6 lbs; 2.72kg (w/aluminum j-box)
9 lbs; 4.08kg (w/stainless steel j-box)
Electrical Specifications
Power Input11-30 VDC
Power ConsumptionNormal operation = 30mA @24V (<0.75 watt)
Maximum = 50mA @24V (1.2 watts)
Inrush Current500mA @ 24V (typical)
RFI/EMI ProtectionComplies with EN50270
Analog OutputLinear 4-20mA DC (1,000 ohms max loop load @ 24VDC)
0mA: All Fault Diagnostics
2mA: In-Calibration
4-20mA: 0-100% full-scale
22mA: Over-range condition
Serial RS-485 OutputRS-485 ModbusTM RTU
Baud Rate (optional)9600 BPS (9600,N,8,1 Half Duplex)
Status Indicators4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan
Set-up Options, and Fault Reporting
Faults MonitoredLoop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration
Cable RequirementsPower/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
I/O ProtectionOver-voltage, Miswiring, EMI/RFI Immunity
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    3 Items found.
943-000000-000
(6566)

DETCON  943-000000-000

Detcon Calibration Sleeve/Wind Guard for use with sensor splash guard for all Detcon sensor heads.



 
377-12EJ01-100
(6180)

DETCON  377-12EJ01-100

Detcon Ethylene Oxide (C2H4O) plug-in sensor for DM-700-C2H4O



 
S927-555500-100
(6607)

DETCON  S927-555500-100

Detcon DM-700-EC Electrochemical Universal ITM (Intelligent Transmitter Module) Spare Part for SO2, C2H2, AsH3, Br2, C4H6, CO, CL2, CLO2, B2H6, C2H5OH, C2H5SH, C2H4, C2H4O, F2, CH2O, H2, HBr,m HCL, HCN, HF, CH3OH, CH3SH, NO, NO2, O3, PH3 or SiH4

> ETHYLENE OXIDE :    15 Items found.
M001-0069-000
(5997)

MPOWER  M001-0069-000

mPower UNI MP100 Portable Single Gas Detector for detection of Ethylene Oxide (ETO) 0-100ppm or 0-200ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$278.40 
364-455-02-365-710-11
(6152)

DELPHIAN  364-455-02-365-710-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Ethylene Oxide (ETO) 0-10 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

BWS1-E-Y
(6386)

BW  BWS1-E-Y

BW Solo Serviceable Single-gas Detector for Ethylene oxide (ETO) 0-100 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PC3-6224
(6804)

PROSENSE  PC3-6224

Prosense PC3-6224 Gas Detector with Electrochemical sensor for Etylene Oxide (ETO) with range 0-20 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$823.68 
P-6234
(6780)

PROSENSE  P-6234

Prosense P-6234 Gas Detector with Electrochemical sensor for Ethylene Oxide (ETO) with range 0-20ppm or 0-100ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$900.90 
PQN-6234-1/2
(6952)

PROSENSE  PQN-6234-1/2

Prosense PQN-6234 Gas Detector with Electrochemical sensor for Etylene Oxide (ETO) with ranges 0-20ppm or 0-100ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
PQD-6234-1/2
(6741)

PROSENSE  PQD-6234-1/2

Prosense PQD-6234 Gas Detector with Electrochemical sensor for Etylene Oxide (ETO) with ranges 0-20ppm or 0-100ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,235.52 
41001AL-0-1061/1000P/L0
(7161)

RC SYSTEMS  41001AL-0-1061/1000P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Ethylene Oxide (ETO) 0-10 to 0-1000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,753.24 
51001AL-0-1061/1000P/L0
(7162)

RC SYSTEMS  51001AL-0-1061/1000P/L0

RC Systems SenSmart 5100 3-wire gas detector for Ethylene Oxide (ETO) 0-10 to 0-1000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,809.09 
961-EJ0026-100G
(6358)

DETCON  961-EJ0026-100G

Detcon DM-100-C2H4O Electrochemical Ethylene Oxide (C2H4O) 0-100ppm Sensor Assembly with optional loop powered display. 4-100 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

GDS-IR-1-127-0
(1741)

GDS  GDS-IR-1-127-0

GDS GDS-IR Infrared Remote Gas Detector Transmitter with Stainless steel sensor head configured for Ethylene Oxide (ETO) with range 0-50% LEL (0-1.5% Vol), 3-Wire output 4-20 mA transmitter, Explosion Proof (XP) Class I, Div 1 SIL-2 Rated.

2100AL-0-9087/050P/L0
(134)

RC SYSTEMS  2100AL-0-9087/050P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Ethylene Oxide (EtO) 0-50ppm to 0-100ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$2,276.62 
31001AL-0-9016/050P/L0
(5781)

RC SYSTEMS  31001AL-0-9016/050P/L0

RC Systems SenSmart 3100 3 wire gas detector for Ethylene Oxide (ETO) 0-50ppm to 0-100ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$2,454.54 
6100AL1-0-1061/1000P
(7004)

RC SYSTEMS  6100AL1-0-1061/1000P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Ethylene Oxide (ETO) 0-10 to 0-1000ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,603.89 
I-900G-C2H4O-0005
(7113)

INTERSCAN  I-900G-C2H4O-0005

Interscan GASD 8000 Portable Trace Gas Detector with smart sensor for continuous air sampling of Ethylene Oxide (ETO). Anodized aluminum enclosure. Includes rechargeable batteries.

Configure

$5,688.00 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.