Prosense Pqd-8136-1/2 | Voc Pid | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

PROSENSE   PQD-8136-1/2

SKU# (6720)



PROSENSE PQD-8136-1/2
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Prosense PQD-8136 Gas Detector with 10.6 eV PID sensor for VOC (Volatile Organic Compounds) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Marine Bureau Veritas Certification (MED), Alarm Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

DISPLAY   4-20 mA   RELAYS   UL   ATEX   IECEX   CSA   UL   DIV 1   ZONE 1   ZONE 2   SIL2   HART   MODBUS

PQD-8136-1/2   
3,065.87

Cable Entries
Range
Relays
IP66 Adaptor
No calibration port
Stainless Series Enclosure
SIL2
HART
Certification
Remote Sensor

 7 Days  ]
3 Variants of base SKU
OLED Display

PROSENSE "PQD" Series fixed gas detectors are certified with ATEX/IECEx and SIL2.

Ex-proof Safety

The continuous measurement of toxic and explosive gases is done safely in hazardous areas thanks to the ex-proof housing.

Performance Approval

It complies with the measurement performance criteria in accordance with the IEC EN 60079-29-1 standard.

Functional Safety

Prosense promotes SIL approved products to reduce safety risks associated with increasingly complicated systems as malfunctioning equipment could pose a potential risk. PQ series has ongoing process for SIL-2.

Robust and Durable

SS316 stainless steel sensor head performs perfectly under harsh environmental conditions with the IP65/ IP66 protection class.

Accurate Readings

Pellistor, Electrochemical, PID, and Infrared sensors undoubtedly provide an accurate and sensitive measurement.

Ready to Operate

4-20mA Analog and Modbus RS485 RTU outputs are provided onboard to operate properly without any additional setup.

Easy Maintenance

PQD Series detectors allow sensor replacement with pre-calibrated sensor head thanks to the Procell technology.

OLED Display

The OLED screen can be easily read from any angle.

SAFELOG Data Logger

PQD Series records status up to 250 events. In case of sudden power cut, you can save the data thanks to the cell battery.

Automatic Calibration

Detector calibration can be done automatically via preset values recorded in detector software once calibration requirements are provided.

Pellistor-Saver Mode

Detectors power off the sensor in high gas concentration in order to properly secure the operational lifetime of pellistor sensor.

Auto Analog Signal Calibration and Monitoring

PQD Series detectors continuously check the analog output signal level to match the measurement level before promptly transferred to the panel. PQD Series adjusts the signal level in case of any deviation and generates a fault signal when the adjustment fails.

Zero Suppression

Adjusting, the detector can show a certain measurement level as 0 (zero) to avoid unnecessary concerns.

Simple External Equipment Control

Optional relay module enables you to use it as an independent gas detection system with two arbitrarily adjustable concentration alarms and one fault alarm.

Continuous Self-Test

The detectors check itself continuously to make sure it operates perfectly and indicates a fault in case of any failure.

Adjustable Parameters

All parameters can be easily changed according to the application requirements or facility standards.

Remote Display

Depending on the application requirements, the screen can be placed separately.

Easy Status Recognition

Colored LEDs (green, yellow and red) provide additional alarm and status information.

Maintenance via Software

Prosense provides software to maintain your active system easily and calibrate the gas detectors properly via computer.

Applications
  • Oil&Gas
  • Petrochemical
  • Onshore/Offshore
  • Steel-Metal Industry
  • Chemical Industry
  • Process Industry
  • Gas Distribution Stations
  • Water Treatment Plants

Specifications PQD-XY36
Sensor Technology PID 10.6 eV
Output Signal 4-20mA and Modbus RS485
Sensor Warm-Up 60sec
Response Time(T90) <30sec
Accuracy %1
Operating Temperature -40°C ~ +70°C
Humidity 0~ 100%RH Non-Condensing
Input Min 10VDC - Max 32VDC - Nominal 24VDC
Display 128x64 Graphic OLED
5 LED indicator for detector status
Event Logging Records alarm, fault and maintenance events up to 250 logs
Power Consumption Max. 4W
Relay Outputs 2 Alarms (Programmable) and 1 Fault (All relays are NO/NC adjustable)
Cable Entry 3x 1/2''NPT or 3x 3/4''NPT or 3x 3xM20
IP Rating IP65/IP66
Junction Box Epoxy Painted Die-Cast Aluminum / 316 Stainless Steel
Sensor Head 316L Stainless Steel
Dimensions/Weight 196,96x145,99x112mm / 2100gr
ATEX Marking II 2G Ex db IIC T6 Gb
II 2G Ex mb db IIC T6 Gb
I M2 Ex db I Mb
Hazardous Class ATEX/IECEx Zone 1 - Zone 2 - M2
UL/CSA Class I Division 1 Group A, B, C& D
Certificates ExVeritas 18 ATEX 0371X
IECEx EXV 18.0021X
FTZU 18 ATEX 0086
IEP12 ATEX 6118X
UL E521536
Optional SIL2
Standards IEC EN 60079-0
IEC EN 60079-1
IEC EN 60079-18
IEC EN 60079-29-1
Warranty 12 months from date of shipment from Prosense Technology
Export Info
Made inTurkey
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping & Handling

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    17 Items found.
PR-KT12
(6978)

PROSENSE  PR-KT12

Prosense 1/2" NPT ATEX Certified Blind Plug Aluminum for P, PQ and B Series gas detectors



$16.73 
PR-NYY12
(6976)

PROSENSE  PR-NYY12

Prosense 1/2"NPT ATEX Certified Cable Gland Aluminum for P, PQ and B Series gas detectors



$16.75 
PY-SS
(7589)

PROSENSE  PY-SS

Prosense Sunshade/Rain Protector for PQ, PX, P, PE, PEK, PC3 series gas detectors.



$89.97 
P-GTA
(7212)

PROSENSE  P-GTA

Prosense Celling Mount Collecting Cone for P and PQ gas detectors, Diameter 50cm, Hight 20cm, Material Steel plate optional stainless steel.

Configure

$100.39 
PK-K30T
(6768)

PROSENSE  PK-K30T

Prosense Teflon Calibration cup/cap for P, PE, PQ and B Series gas detectors, tubing entry 4mm diameter tubing. Optional SS316

Configure

$110.11 
P-DMK
(7213)

PROSENSE  P-DMK

Prosense Duct Mount/Pipe Mount adapter kit for PQ-S, PQ, PX, P Series Gas Detectors, made of Delrin

Configure

$133.93 
P-ASU-2
(6989)

PROSENSE  P-ASU-2

Prosense flow adapter cell for SH30 and SH20 sensor heads used in PQ, P, PE and PC3 series, gas sampling applications. For 6mm OD Tubing made of corrosion-resistant Teflon.



$140.33 
10386052
(1294)

PORTAGAS  10386052

Calibration Gas Isobutylene (C4H8) 500 ppm Balance Air 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$158.48 
10365510
(7059)

PORTAGAS  10365510

Calibration Gas Isobutylene (C4H8) 50 ppm Balance Air 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$158.48 
SP-PQ-DT
(7036)

PROSENSE  SP-PQ-DT

Prosense OLED Display Assembly for PQD series gas detectors



$421.01 
PQ-PD05A
(7056)

PROSENSE  PQ-PD05A

Prosense Handheld Terminal for maintenance, diagnostics, alarm setting, configuration, test and calibration of Prosense PXN, PXD, PQN, PQD, P and PC3 series gas detectors, uses RS-485 Modbus to connect to the detectors.



$509.78 
S-DPX004
(7030)

PROSENSE  S-DPX004

Prosense S-DPX004 Gas Detector Controller, Alarm Panel for 4 x 4-20 mA Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. ... more

Configure

$971.58 
SP-PQ-TB05
(7031)

PROSENSE  SP-PQ-TB05

Prosense PQ Transmitter/Main Board for PQD and PQN series gas detectors



$1,052.54 
S-DPX008
(7032)

PROSENSE  S-DPX008

Prosense S-DPX008 Gas Detector Controller, Alarm Panel for 8 x 4-20 mA Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. ... more

Configure

$1,133.50 
S-DPX032
(7033)

PROSENSE  S-DPX032

Prosense S-DPX032 Gas Detector Controller, Alarm Panel for 32 x RS485 MODBUS RTU Detectors + 8 x 4-20 mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common ... more

Configure

$1,295.44 
S-DPX064
(7034)

PROSENSE  S-DPX064

Prosense S-DPX064 Gas Detector Controller, Alarm Panel for 64 x RS485 MODBUS RTU Detectors + 8 x 4-20 mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common ... more

Configure

$2,428.95 
S-DPX128
(7035)

PROSENSE  S-DPX128

Prosense S-DPX128 Gas Detector Controller, Alarm Panel for 128 x RS485 MODBUS RTU Detectors + 8 x 4-20 mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common ... more

Configure

$4,210.17 
> VOC PID :    19 Items found.
SV-8106
(7391)

PROSENSE  SV-8106

Prosense SafeVader SV-8106 Fixed Gas Detector with 10.6 eV PID sensor for Volatile Organic Compounds (VOC) with range 0-100 ppm or 0-1000 ppm. 4-20 mA Analog, Modbus RS485 RTU and relay outputs (Alarm1, Alarm2, Fault). 12 to 28VDC. ABS Plastic ... more

Configure

$2,216.64 
PXN-8136-1/2
(7352)

PROSENSE  PXN-8136-1/2

Prosense PXN-8136 Gas Detector with 10.6 eV PID sensor for Volatile Organic Compounds VOC with range 0-100 ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Relay and HART ... more

Configure

$2,590.87 
KL0100A1-SSA0100C
(7656)

KWIKSENSE  KL0100A1-SSA0100C

Uniphos KwikSense Lite Gas Detector with PID Sensor 10.6 eV Lamp for Volatile Organic Compounds (VOC) 0-20 ppm to 0-4000 ppm. Includes 4-20 mA and 1 Alarm relay outputs, OLED Display, Aluminum Enclosure. ATEX/IECEx/CE Approved, IP66, 3-wire.

Configure

$2,731.05 
PXD-8136-1/2
(7351)

PROSENSE  PXD-8136-1/2

Prosense PXD-8136 Gas Detector with 10.6 eV PID sensor for Volatile Organic Compounds VOC with range 0-100 ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Relay and HART ... more

Configure

$2,774.39 
SP-0648-1083/0020L_S_
(7472)

RC SYSTEMS  SP-0648-1083/0020LS

RC Systems SensePoint single point gas detector for Volatile Organic Compounds (VOC) with GEN 2 smart Electrochemical sensor. Includes backlit display, 4-20 mA and RS-485 Modbus outputs and 3 programmable relays. 24 VDC. NEMA 4x Fiberglass enclosure.

Configure

$2,818.18 
PQN-8136-1/2
(6965)

PROSENSE  PQN-8136-1/2

Prosense PQN-8136 Gas Detector with 10.6 eV PID sensor for VOC (Volatile Organic Compounds) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Marine Bureau Veritas Certification ... more

Configure

$2,860.76 
KS1000U2-SSA0100C
(7633)

KWIKSENSE  KS1000U2-SSA0100C

Uniphos KwikSense Pro Smart Gas Detector with PID Sensor 10.6 eV Lamp for Volatile Organic Compounds (VOC) 0-20 ppm to 0-4000 ppm. Benzene, Isobutylene or VCM. Includes 4-20 mA, MODBUS RS-485 and HART outputs, 3 Alarm relays, OLED Display, ... more

Configure

$2,935.05 
GM/BX-1-61-R0005/0-00-R000/0
(7299)

GDS  GM/BX-1-61-R0005/0-00-R000/0

GDS GASMAX BX Gas Detector for VOC (Volatile Organic Compounds) 0-5 to 0-100ppm, PID Sensor 10.0, 10.6 or 11.7eV , 3-wire. Includes 4-20 mA analog output and optional 3X isolated 5A alarm relays and MODBUS interface. TFT backlit display. CSA ... more

Configure

$3,100.00 
M011-0004-000
(6337)

MPOWER  M011-0004-000

mPower NEO Photo-ionization Handheld Gas Detector for Volatile Organic Compounds (VOC). Ranges from 1 ppb up to 15,000 ppm with 10.6 eV lamp (Benzene version with 9.8 eV lamp). Audible (90dB0), Visual (flashing LEDs) and wireless remote alarms. Built-in wireless ... more

Configure

$3,354.00 
TV2SXBMX-X
(7402)

ION SCIENCE  TV2SXBMX-X

Ion Science TVOC 2 Fixed Detector for Volatile Organic Compounds (VOCs) 0-10 to 0-1000 ppm. MiniPID 2 sensor with 10.6eV lamp. Diffusion sampling, optional pumped version with adaptor. 5-28 VDC. 4-20 mA output. LCD display. ATEX and IECEx approvals for ... more

Configure

$3,489.15 
55001AL-0-9027/100P/L0
(7120)

RC SYSTEMS  55001AL-0-9027/100P/L0

RC Systems SenSmart 5500 3-wire gas detector for Volatile Organic Compounds VOC 10.0eV or 10.6eV with GEN2 smart sensor, Color backlit LCD Display and 4-20 mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Div 1 (Explosion-Proof). ... more

Configure

$3,553.24 
71001AL1900_-0-1083/0020P/L0-0000
(7422)

RC SYSTEMS  71001AL1900-0-1083/0020P/L0-0000

RC Systems SenSmart 7100 Wireless gas detector for Volatile Organic Compounds (VOC) with GEN 2 smart Electrochemical sensor, 900Mhz or 2.4Ghz. Includes LCD Display, Five flashing Alarm LEDs and D-cell lithium battery. Optional 10-30 VDC power board. Aluminum, Stainless Steel ... more

Configure

$3,736.36 
35001AL-0-9029/0010P/L0
(6896)

RC SYSTEMS  35001AL-0-9029/0010P/L0

RC Systems SenSmart 3500 3 wire gas detector for Volatile Organic Compounds VOC 0-40 ppm to 0-1000 ppm Isobutylene with 'ST-48' smart transmitter with 10.0eV or 10.6eV PID sensor with arctic heater. Includes Graphic LCD Display, LED indicator and 4-20 ... more

Configure

$3,938.96 
TXLLSLBMR-0000
(5956)

ION SCIENCE  TXLLSLBMR-0000

Ion Science Tiger XTL handheld detector for Volatile Organic Compounds (VOCs) with PID sensor (0-5000ppm). 10.6 eV Krypton lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, keypad, data logger, 2 visual alarms and sounder. ATEX, IECEx, ... more

Configure

$4,380.60 
FA2XSXBXX-3000D
(5955)

ION SCIENCE  FA2XSXBXX-3000D

Ion Science Falco 2 Fixed Detector for Volatile Organic Compounds (VOCs) in condensing atmospheres and extreme weather. MiniPID sensor in both 10.6 eV and 10.0 eV variants. Pumped or diffused versions available. RS485 Modbus, 2 x Alarm/Control Relays and 4-20 ... more

Configure

$4,496.10 
967-PB5520-010A
(6066)

DETCON  967-PB5520-010A

Detcon PI-700 Universal Smart Gas Sensor with Photo Ionization Detector (PID) technology for VOC 0-10 ppm to 0-5000 ppm. 4-20 mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Built-in numeric display. Water-Proof, Corrosion-Proof and Vibration-Proof. NEMA4X. IP66. CSA (Class ... more

TXSXSLBMP-0517
(5957)

ION SCIENCE  TXSXSLBMP-0517

Ion Science Tiger XTS Select handheld detector for Total Aromatic Compounds (TACs) including Benzene, Toluene and Acetone with PID sensor (up to 20000ppm). 10.0 eV Krypton lamp. Humidity resistant, rapid and accurate. IP65. Includes Li-ion battery, USB port, keypad, ... more

Configure

$6,881.70 
TXXXSLBMP-0005
(5163)

ION SCIENCE  TXXXSLBMP-0005

Ion Science Tiger XT Select PID (photoionization) handheld detector for Volatile Organic Compounds (VOCs) with dynamic range 1ppb to 20000ppm and internal gas table with over 750 compounds. 10.6 eV Krypton lamp, optional 11.7 eV lamp. Humidity resistant, rapid and ... more

Configure

$7,225.05 
H-D03-0009-000
(4307)

HONEYWELL  H-D03-0009-000

Honeywell RAEGuard 2 PID Photoionization Detector for VOCs (Volatile Organic Compounds), 10.6 eV Lamp only. 10 to 28 VDC. 4-20 mA three-wire and RS-485 Modbus outputs. Explosion-proof stainless-steel enclosure. Graphic display. LED light status indicator. IP65. UL approved for Class ... more

Configure

$9,197.33 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.