GDS GDS-IR2 Infrared Stainless Steel Sensor Head for detection of Ammonia (NH3) in Harsh Enviroments. 3-Wire output 4-20 mA transmitter. CSA certified for use in Class 1 Division 1.

GDS-IR2-1-301-0   
Please Email us your request for quote   

Sensor Head
Range
Options
Rain Shield
Enclosure
Tag

 3 Weeks  ]
224 Variants of base SKU / 30 Shown below
  • Highly reliable infrared sensing technology
  • High speed response for critical applications (T50 less than 10 sec)
  • Five year warranty; virtually maintenance free
  • Immune to poisoning and etching by common solvents & gases
  • Rugged stainless steel construction with no moving parts
  • Available with extended length optical path for higher sensitivity
  • Heated optical chamber maintains accuracy in cold conditions
  • Operates in constant hydrocarbon and anaerobic atmosphers
  • Ten discrete fault indication values for all failure states
  • Straight line optical path eliminates need for mirrors
  • Managed power-up delay reduces initial load on power supply
  • Industry standard 4-20mA current loop calibrated output
  • IECEx Certified for Class I Zone 1, Group IIC
  • CSA Certified C22.2 No. 152-1984 Performance Tested
  • Manufactured in USA

The GDS-IR2 Infrared Gas Sensor uses proven, reliable infrared sensing technology to detect dangerous levels of carbon dioxide or explosive levels of methane, propane and other hydrocarbons. The GDS-IR2 sensor is CSA certified for use in Class 1 Division 1 explosive environments and is CSA performance tested.

Advanced Infrared Technology

The GDS-IR2 infrared combustible gas sensor offers low total cost of ownership and a seventeen-year MTBF rating. Designed for especially harsh environments, the GDS-IR2 is virtually maintenance-free and immune to poisoning or etching by any known gas. The sensor element fea- tures a self-compensating optical bench, heated optical chamber and fault indication for all failure modes. The optical path can be easily opened for cleaning.

No periodic span calibrations are required. On initial setup and after each cleaning, a simple ‘auto zero’ procedure is used to establish proper operating conditions.

Flexibility

The GDS-IR2 can be calibrated to read a wide range of combustible hydrocarbons, including methane, propane, hexane, pentane, ethanol, Jet-A, isobutane, propylene and isoproply alcohol, as well as carbon dioxide to 5% by volume. GDS-IR2 sensors are factory programmed and calibrated when shipped and can be field programmed for alternate response curves. Both LEL and % by volume ranges are available.

GASMAX + GDS-IR2 Combo

When combined with the GASMAX II or GASMAX CX monitor, the duo provides local display, 4-20mA output with diagnostics, optional second electrochemical sensor, isolated 4-20mA outputs or MODBUS slave interface with programmable relays. The GASMAX CX also provides dual serial MODBUS and an Ethernet interface with built-in web server and MODBUS/TCP database.

Reliable Detection

The GDS-IR2 is manufactured in the USA and includes a five year operational warranty. Applications include refineries, onshore and offshore drilling platforms, fuel loading docks, biogas processing, breweries, wastewater treatment facilities and natural gas storage and distribution.

GDS-IR2 SPECIFICATIONS
Power Input: 18-32VDC at 5 watts (typical). Delayed IR source turn-on minimizes inrush power for distributed systems.
Max Current Average: 210 mA, peak 400 mA at 24VDC
Display None.
Sensor Technology Reliable infrared sensing technology with patented self-compensating optics and easy-to-clean optical path
Standard Output Standard 3-wire 4-20mA current source. Max loop R is 1000 ohms with nominal 24VDC power supply
Optional Alarm Conditions Discrete 4-20mA output levels indicate general fault, reference & optics fault, warm-up, zero drift fault, calibration fault, zero and span set and overrange conditions.
Accuracy ± 5% of value or 0.5% of scale
Repeatability ± 3% LEL, 0-50% LEL ± 5% LEL, 51 - 100% LEL
Response Time T50 < 10 seconds; T90 < 20 seconds
Temp -40°C to +70°C at 0 to 99% RH (Sensor 1HT to +90°C)
Sensor Housing Anodized Aluminum
Optional #316 Stainless Steel [SI]
Junction Box Painted Aluminum
Optional #316 Stainless Steel [SS]
Dimensions with j-box Width 5.4”, Height with junction box 16”, Depth 3.5”
Shipping weight 8 pounds (Aluminum)
Approvals CSA Certified for Class I, Div 1, Grps B, C, D
C22.2 No.152-M1984 (R1997) for performance
IECEx Certified for Class I, Zone 1, Group IIC
Warranty 5 years from date of purchase
12 years on infrared source
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    2 Items found.
1200-0280
(3155)

GDS  1200-0280

GDS Gas Detector Calibration Gas Cylinder Ammonia (NH3) 300ppm. Balance Air. 58L Aluminium Cylinder.

90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
> AMMONIA :    42 Items found.
6100AL1-0-1015/0100P
(7001)

RC SYSTEMS  6100AL1-0-1015/0100P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Ammonia (NH3) 0-100 to 0-1000ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class I Div 2 (Non-Incendive). IP66.

Configure

$2,389.61 
QTU-QRU-C-2111
(6984)

SPECTREX  QTU-QRU-C-2111

SPECTREX SafEye Quasar 960 open path gas detector and source with ultraviolet technology to detect toxic Ammonia (NH3) at very low concentrations. Long range and high speed response. 24 Vdc. 0-20 mA, HART and RS-485 Modbus outputs. Stainless steel housing. IP66 and IP68. NEMA 250 6P. FM, ATEX, IECEx, CSA and SIL2 approvals.

Configure

$27,342.56 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.