Intec Spc3-1120-200us | Ammonia | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

INTEC   SPC3-1120-200US

INTEC SPC3-1120-200US
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Intec Controls PolyGard SPC3-1120 Sigle-Point Gas Detector for Ammonia (NH3) 0-300 / 0-1000 ppm, 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified. *** phased out replaced by SGC6 ***

Inquiry

APPLICATION

To detect and control levels of ammonia (NH3) and other gases in a wide variety of commercial and industrial applications such as the ammonia level in chiller equipment rooms, food storages, freezers, arenas, breweries, and ventilation systems, etc. The controller can communicate with any compatible electronic analog control, DDC/PLC control or automation system via binary and/or analog output signal.

FEATURES
  • Continuous monitoring
  • One (1) built-in NH3 electrochemical sensor
  • Easy plug-in sensor
  • One (1) remote analog input, 4-20 mA
  • One (1) digital input
  • Two (2) relay outputs:
    Four stage control
    Fail-safe assignable
  • One (1) analog output, (0)4-20 mA / (0)2-10 VDC - Selectable for low, high, or averaging
  • One (1) 24 VDC switched output
  • Liquid Crystal Display (LCD)
  • LED status indicators
  • Accepts toxic or combustible gas, refrigerant, temperature or humidity secondary remote sensor input
  • Built-in horn
  • Keypad user interface
  • Simple menu-driven programming
  • Modular technology
  • Overload & short-circuit protected
  • NEMA 4X enclosure
  • Easy maintenance

Specifications
Electric
Power supply 24 VAC/VDC, -20%/+15% 50/60 Hz, reverse polarity protected
Power consumption 5 VA (0.2 A) w/ (1) remote sensor connected
Sensor Performance
Gas detected Ammonia (NH3)
Sensor element Electrochemical, diffusion
Range 0-300 ppm or 0-1000 ppm, fixed “refer to Ordering Information”
Resolution 4.0 ppm
Repeatability ± 3.0 % of reading
Long term output drift < 5% / 6 months
Response time t90 < 35 sec.
Sensor life expectancy 2 years, normal operating environment
Sensor coverage 2,000 sq. ft., max 3,000 sq. ft. (180 m2, max 280 m2), under “ideal conditions”
Installation Location
Mounting height 1 ft. (0.3 m) below ceiling
Type of Control
General Four-stage (S1 to S4) control, assignable up to two (2) binary/ relay, horn/audible alarm, and 24 VDC / 50 mA switched outputs, i.e. low-high stage for relay output, horn / audible alarm and switched 24 VDC at any stage for remote alarming
Analog input One (1) 4-20 mA, for additional remote sensor, load < 55 mA / 200 Ω, reverse polarity protected
Analog reading Current and mean (average) value
Stage level / setpoint Field adjustable over full range, four (4) stages (S1 to S4) per analog input, assignable to current or mean (average) value
- hysteresis/ switching differential Selectable for each sensor point
Digital input One (1); can be assigned to any relay (R1, R2)
- application Remote audio/visual alarm reset or override function
Type of Control (cont...)
Relay outputs (R1, R2) w/ status LEDs (1) SPDT (R1), and (1) SPST-NC or SPST-NO (R2), jumper selectable
Contact rating
-each stage level (S1-S4)
-sensor fail-safe
30 VAC/VDC, 0.5 A, max.
Assignable to any relay
Assignable to any stage level
Time delay switching Selectable for make and brake of each sensor point (SP1 to SP2) 0‐9,999 seconds
Analog output One (1), (0)4‐20 mA, load < 500 Ω;(0)2-10 VDC, load > 50K Ω; jumper selectable; polarity protected, assignable to low, high or averaging of sensor inputs
VDC switched output One (1) 24 VDC, 50 mA max
Audible alarm 83 db @ unit, enabled or disabled, selectable; assignable to stage level S1, S2, S3 or S4
Alarm acknowledgment Menu-driven and system reset function for latched relays
User Interface
Keypad type Refer to illustration “Keypad User Interface”
Touch buttons Four (4)
Status LED’s Four (4), for system on, stage status, and failure
Digital display Liquid Crystal Display (LCD), two lines, 16 characters per line, 1 digit resolution
-unit display Menu selectable, per sensor; ppm, %v/v, %LEL, °F or %RH
Environmental
Permissible ambient
-working temperature 14°F to 122°F (-10°C to 50°C)
-storage temperature 23°F to 86°F (-5°C to 30°C)
-humidity 15 to 95% RH, non-condensing
-working pressure Atmospheric ± 10%
Physical
Enclosure (panel)
-material Polycarbonate, UL 94-HB, fire-retardant
-conformity UL 50 standards
-color Light gray
-protection NEMA 4X (IP65)
-installation Wall (surface) mounted, or single gang electrical box
Dimensions (H x W x D) 5.12 x 5.12 x 2.95 in.
Wire connection Terminal blocks, screw type for lead wire
Wire size Min. 24 AWG (0.25 mm 2 )
Max 14 AWG (2.5 mm 2 )
Wire distance Max. loop resistance 450 Ω (= wire distance plus controller input resistance)
Weight 0.6 lb. (0.3 kg)
Approvals / Listings
-unit rating NRTL Certification to STD
ANSI/UL 61010-1
CE
EMV-Compliance 2004/108/EWG
Low voltage directive 73/23/EWG
-relays (R1-R2) UL Recognized, E41515
CSA, C22.2 No. 0, No. 14 (File No. LR31928)
-enclosure UL Listed, E208470
CSA Certified, E208470
Warranty Two years material and workmanship, 12 months normal exposure for sensor element
> AMMONIA :    43 Items found.
6100AL1-0-1015/0100P
(7001)

RC SYSTEMS  6100AL1-0-1015/0100P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Ammonia (NH3) 0-100 to 0-1000ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class I Div 2 (Non-Incendive). IP66.

Configure

$2,389.61 
GDS-IR2-1-301-0
(5829)

GDS  GDS-IR2-1-301-0

GDS GDS-IR2 Infrared Stainless Steel Sensor Head for detection of Ammonia (NH3) in Harsh Enviroments. 3-Wire output 4-20 mA transmitter. CSA certified for use in Class 1 Division 1.

QTU-QRU-C-2111
(6984)

SPECTREX  QTU-QRU-C-2111

SPECTREX SafEye Quasar 960 open path gas detector and source with ultraviolet technology to detect toxic Ammonia (NH3) at very low concentrations. Long range and high speed response. 24 Vdc. 0-20 mA, HART and RS-485 Modbus outputs. Stainless steel housing. IP66 and IP68. NEMA 250 6P. FM, ATEX, IECEx, CSA and SIL2 approvals.

Configure

$27,342.56 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.