Notifier Hpff12 | Notifier | Power Supplies | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   HPFF12

NOTIFIER HPFF12
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier HPFF12(E) 12 Amp and 24 Volt Power Supply to extend the power of existing Notification Appliance Circuits (NACs) or provide power for auxiliary devices. 4 NAC and 1 aux outputs. 8 status LEDs. UL, CSFM and FM listed.

HPFF12   
Please Email us your request for quote   

Version

   4 Weeks  ]

The Honeywell HPFF12(E) and HPFF12CM(E) are Notification Appliance Circuit (NAC) Expander Power Supplies designed to extend the power capabilities of existing NACs and provide power for auxiliary devices. The HPFF12 and HPFF12CM connects to any 12 or 24V Fire Alarm Control Panel (FACP) or operates stand-alone.

They provide regulated and filtered 24VDC power to four NAC's and an auxiliary output. The NAC outputs are rated at 3.0 amps each and the auxiliary output is rated at 2.0 amps (this output is continuously supplied, even in alarm, and therefore must be taken into account for power supply loading and battery size calculations). The combined output cannot exceed 12.0 amps.

The HPFF12 and HPFF12CM provide independent output circuit supervision so in the event of a NAC fault they can notify the attached FACP. In addition they have a trouble memory feature that displays past troubles (by NAC) for rapid diagnostics. Synchronization is built in for five appliance brands.

The HPFF12 and HPFF12CM have two fully independent supervised initiating circuits that can be used for synchronized strobes and coded horns. Their NAC outputs may be configured as any of the following:

  • four Class B (Style Y)
  • two Class A (Style Z)
  • two Class B and one Class A
  • four Class A with the optional HPP31076 Class A adapter

These power supplies contain an internal Battery charger capable of charging up to 26.0 amp-hour (AH) batteries.

The HPFF12 is mounted in a lockable wall cabinet that can accommodate up to two 18AH batteries. The HPFF12CM is designed to mount in Notifier’s equipment series enclosure (order separately). Each HPFF12CM can accommodate two 12AH batteries.

One of the most challenging aspects of a retrofit application is locating the existing End-of-Line (EOL) resistor. In these applications that have EOL values other than the 3.9k normally used with the HPFF12, a single resistor matching the existing EOL can be used as a reference for all the outputs. This feature speeds installation and system checkout because the actual EOL does not need to be located and changed in the circuit. The reference resistor must be within the range of 1.9k to 25k.

NOTE: 4 separate programming resistors for the HPFF12 are provided in the hardware kit shipped with each HPFF12(E) and HPFF12CM(E). They are 3.9K (5 of these are provided, need only 1 for programming), 2.2K (1 each), 4.7K (1 each) and 10K (1 each)

Features
  • Four (4) power limited supervised notification application circuits (NAC's) capable of supplying +24VDC at 3.0 amp maximum each.
  • NAC output circuits may be configured as any of the following:
  • Four Class B (Style Y).
  • Two Class B & one Class A.
  • Two Class A (Style Z).
  • Four Class A (requires the HPP31076 Class A adapter).
  • Four field-programmable operational modes:
    • Pass-through.
    • Temporal generator.
    • Sync generator.
    • Pass-through Filtered.
  • Temporal coding and sync protocols compatible with the following notification appliance brands:
    • System Sensor.
    • Faraday.
    • Amseco.
    • Cooper-Wheelock.
    • Gentex.
  • Protocol pass-through for synchronizing large systems.
  • Two fully independent supervised input/output control circuits.
  • Redundant activation operation for survivability.
  • Supports FACP’s Selectable Silence ability.
  • 2.0 amp auxiliary continuously supplied output.
  • Eight status LEDs.
  • Supervised AC input, battery voltage, auxiliary output, charger, and earth ground faults.
  • Trouble indication for supervision of the following:
    • NAC circuits.
    • Auxiliary output.
    • AC input.
    • Battery charger voltage.
    • Earth ground faults.
  • Optional two-hour delay for AC loss.
  • Separate Trouble and AC Fail Form-C relay contacts.
  • The Trouble Form-C relay contacts selectable for immediate or a 2 hour delay with AC failure.
  • 26 AH battery charger capability:
    • HPFF12(E) supports two 12V 18AH batteries
    • HPFF12CM(E) supports two 12V 12AH batteries per unit.
  • NAC Overload protection and indication.
  • Provision for mounting single or 6 circuit addressable control or relay modules inside the enclosure. (Use mounting kit PN 90475.)
  • Standard Honeywell key and lock can be replaced with the NOTIFIER key and lock.
Listings and Approvals

Listings and approvals below apply to all. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. UL 864 9th Edition.

  • UL Listed: S24562
  • Seismic Certification of Non-Structural Electrical Components and Systems
  • FM Approved
  • CSFM: 7315-1637:0102

Specifications
Primary Input Power:120VAC, 60Hz, 5.0A standard; 240VAC, 50Hz, 2.80A on units with E suffix.
Secondary Power:24 volt operation: two 7-26 AH batteries.
Battery Charging Capacity:Up to 26 AH batteries.
HPFF12 Cabinet:Holds up to two 18AH batteries.
HPFF12CM:Holds up to two 12AH batteries.
Total Output Current:12.0A max.
Standby Current:0.075 A.
Auxiliary Power Output:2.0A under all conditions.
NAC Output Ratings:24VDC fully regulated, 3.0A max per circuit (12.0A total).
End-of-Line Resistor Range:1.9K to 25k ohm, 1⁄2 watt. Product ships with 4 separate programming resistors. They are 3.9K (5 each - only need one for programming), 2.2K (1 each), 4.7K (1 each) and 10K (1 each)
Common Trouble/ Relay Fail Relay:2.0A at 30VDC.
Input Control Circuits:compatible with 12 and 24 VDC con- trol panel NACs.
Input Control Current (alarm):5.68 mA @ 12 VDC, 12.28 mA @ 24 VDC.
Temperature Rating:32°F to 120°F (0°C to 49°C).
Relative Humidity:10% to 93% non-condensing.
Cabinet Dimensions:HPFF12 Cabinet: 16.65" W x 19.0" H x 5.2" D (42.29 cm W x 48.26 cm H 13.23 cm D).
Large equipment enclosure:
– EQBB-B4: 24" W x 28.5" H x 5.16" D (60.96 cm W x 72.39 cm H x 13.1 cm D).
– EQBB-C4: 24" W x 37.13" H x 5.16" D (60.96 cm W x 71.36 cm H x 13.1 cm D).
– EQBB-D4: 24" W x 45.75" H x 5.16" D (60.96 cm W x 116.21 cm H x 13.1 cm D).

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
FCM-1
(3236)

NOTIFIER  FCM-1

Notifier FCM-1 Series Addressable Control Module for Notification Appliances (horns, strobes, speakers, etc). Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



 
> NOTIFIER :    36 Items found.
BAT-12120-BP
(6940)

NOTIFIER  BAT-12120-BP

Notifier BAT-12180-BP rechargeable battery. 12VDC. 12 AH. 4-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-1250-BP
(6942)

NOTIFIER  BAT-1250-BP

Notifier BAT-1250-BP rechargeable battery. 12VDC. 5 AH. 10-unit bulk pack, Overcharge protected. ABS high-impact case.



 
XP6-R
(6930)

NOTIFIER  XP6-R

Notifier by Honeywell XP6-R(A) Six Relay Control Module with Form-C Relays. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan® or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP6-C
(5122)

NOTIFIER  XP6-C

Notifier XP6-C Six Circuit Supervised Control Module for horns, strobes or bells that require an external power supply. Short-circuit-protection. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan® or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP10-M
(3724)

NOTIFIER  XP10-M

Notifier XP10-M Ten Input Monitor Module for intelligent alarm systems. Up to 10 addresable Class B or 5 addressable Class A devices. SLC inputs. Green LED indicators. Flexible mounting options. FlashScan® or CLIP operation. UL Listed. CSFM, FM, MEA and MSTM approved.



 
PSE-6
(6924)

NOTIFIER  PSE-6

Notifier PSE-6 (6 amp) or PSE-10 (10 amp) 24 VDC Remote Power Supply Expander with battery charger for 12 or 24 volt alarm control panels (FACP). Up to 7 outputs. UL, ULC, CSFM and FM listed.

APS2-6R
(6938)

NOTIFIER  APS2-6R

Notifier APS2-6R 6.0 Amp Auxiliary Power Supply for the Onyx Series control panels. 150 watt. 24 VDC. SLC circuit. UL, FM and CSFM listed.

BAT-121000
(6939)

NOTIFIER  BAT-121000

Notifier BAT-121000 rechargeable battery. 12VDC. 100 AH. Overcharge protected. ABS high-impact case.



 
NCM-F
(3507)

NOTIFIER  NCM-F

Notifier NCM-F or NCM-W network communication module for NOTIFIER Intelligent Fire Alarm Control Panels and Annunciators. Fiber optic or twisted-pair wire connection. 24 VDC.

KDM-R2
(6932)

NOTIFIER  KDM-R2

Notifier KDM-R2 Keyboard Display Module for CPU2-640. 80 character display and QWERTY programming keypad included.



 
ACPS-610
(6936)

NOTIFIER  ACPS-610

Notifier ACPS-610 Addressable Charger/Power Supply. Provides 6 amps of shared power to four outputs or 10 amps as an external battery charger. SLC circuit. UL, ULC, CSFM and FM listed.

AMPS-24
(6937)

NOTIFIER  AMPS-24

Notifier AMPS-24 Addressable Power Supply for NFS-3030, NFS2-3030 and NCA-2. Charges 7 AH to 200 AH batteries. SLC circuit. UL, ULC, CSFM and FM listed.

LEM-320
(6872)

NOTIFIER  LEM-320

Notifier LEM-320 Loop Expander Module for NOTIFIER’s ONYX® Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.



 
LCM-320
(6871)

NOTIFIER  LCM-320

Notifier LCM-320 Loop Control Module for NOTIFIER’s ONYX® Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.



 
HS-NCM-MF__
(4326)

NOTIFIER  HS-NCM-MF

Notifier HS-NCM High-Speed Network Communications Module. Single or Multi-mode versions available. Allow connection from Notifier Panels to NOTI•FIRE•NET™ with a fiber-optic cable or twisted-pair wire. NFPA Style 4 (Class B) or Style 7 (Class A) operation. 24 VDC, 100Mb baud transmission rate. UL, ULC, CSFM and FM approved.

CPU2-3030D
(6931)

NOTIFIER  CPU2-3030D

Notifier CPU2-3030D Central processing unit for an NFS2-3030 system. Keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control keypad. Requires an AMPS-24(E) power supply.

Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.