The D1xB2X05 is a globally approved explosion proof 5 Joule Xenon beacon.
The robust IP66, Type 4/4X corrosion proof LM6 marine grade aluminium
alloy enclosure ensures suitability for all Class I/II Div 1, Zone 1, 2, 21 & 22
applications.
Approved to UL1638 and CAN/ULC S526 for fire alarm use the D1xB2X05 beacons produce a high
output Xenon flash required for effective signalling in environments with elevated levels of ambient
light. The field replaceable colour filter enhances the strobe and is constructed from UV stable PC.
The robust enclosure features a threaded flame path, four cable entries. Mounting options include
surface via integrated lugs, pendant or by addition of optional multi direction stainless steel
bracket. SIL1 compliant to IEC61508 (2010) as standard – SIL2 version available.
Features
- Four flash rates: 1Hz, 1.3Hz, 1.5Hz & double flash
- Automatic synchronisation on multi-beacon system
- User replaceable Xenon tube secured against shock & vibration
- Stainless Steel guard included as standard
- Field replaceable UV stable lens colour filter
- Stopping plugs included
- 4 x side cable entries, 1 x pendant conduit entry
- Stainless steel fasteners
- Duplicate cable terminations (in & out for daisy-chain installations)
- UL 1638 Visible signaling devices for Fire Alarm
- CAN/ULC S526 Visible signaling device for Fire Alarm
Approvals
- UL/cUL/ULC – File ref: E245313
- IECEx Certificate: IECEx ULD 19.0006X
- ATEX Certificate: DEMKO 19 ATEX 2009X
- SIL1 & SIL2 compliant to IEC61508 (2010)
- CSFM listing: 7300-2279:0508
Coding
- ATEX / IECEx
II 2G Ex db IIC T4 Gb Ta -55°C to +80°C (AC: +70°C)
II 2G Ex db IIC T5 Gb Ta -55°C to +75°C (AC: +50°C)
II 2G Ex db IIC T6 Gb Ta -55°C to +60°C (DC only)
II 2D Ex tb IIIC T104°C Db Ta -55°C to +80°C (AC: T116°C+70°C)
- NEC Class / Zone
Class I Zone 1 AEx db IIC T4 Ta -55°C to +80°C (AC: +70°C)
Class I Zone 1 AEx db IIC T5 Ta -55°C to +75°C (AC: +50°C)
Class I Zone 1 AEx db IIC T6 Ta -55°C to +60°C (DC only)
Zone 21 AEx tb IIIC T99°C Ta -55°C to +80°C (AC: T153°C +70°C)
- CEC Class / Zone
Ex db IIC T4 Ta -55°C to +80°C (AC: +70°C)
Ex db IIC T5 Ta -55°C to +75°C (AC: +50°C)
Ex db IIC T6 Ta -55°C to +60°C (DC only)
Ex tb IIIC T99°C Ta -55°C to +80°C (AC: T153°C +70°C)
- NEC / CEC Class / Div
Class I Div 1 Group ABCD T5 Ta -55°C to +80°C (AC: T4A +70°C)
Class I Div 1 Group ABCD T6 Ta -55°C to +70°C (AC: +40°C)
Class II Div 1 Group EFG T5 Ta -55°C to +80°C (AC: T4 +40°C)
Class III Div 1 Ta -55°C to +80°C (AC: +40°C)