RC Systems SenSmart 1100 gas detector for Carbon Monoxide (CO) 0-100ppm to 0-5000ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

1100ALD-109011/0100P-L0   
1,314.28

Sensor Range
Enclosure Type
Splash Guard

   3 Weeks  ]
20 Variants of base SKU

The RC Systems SenSmart 1100/1200/1300 are complete 2 or 3 wire Gas Detectors available in UL94 flame retardant plastic, or, Class 1 Div 1 316 stainless steel sensor head enclosures These easy-to-install and maintain gas detectors must be connected to an R. C. Systems single or multi-channel receiver to add user calibration and readout functions.

SenSmart 1100 utilizes our electrochemical temperature controlled SMART sensors to transmit O2, H2S, SO2, Cl2, HF, HCL, NO2 (to name a few) 2-wire 4-20mA gas values to R. C. Systems single and multi-channel receivers.

The SenSmart 1200, 1300, 1400 and 1500 utilize our 3-wire direct “bridge” sensor input, including catalytic, PID and infrared, to detect methane, propane, VOC’s, benzene, CO2 and many other compounds. The bridge output is compatible with R. C. Systems single and multi-channel receivers.

Improved design and direct replacement of the GDS Corp. GDS-49

FEATURES HIGHLIGHT
  • Field swappable sensor module. Range and target gas configured on sensor module
  • Improves system noise immunity because low level sensor signals are protected within the sensor head
  • Industry standard 4-20mA signal may be transmitted thousands of feet on 2-wires
  • 316 SS model is suitable for Class 1 Div 1 hazardous areas.
  • Missing or failed sensor forces <2mA FAULT signal
  • Compatible with 1, 2, 4, 16 and 64 channel Receiver/Controllers (user calibration & readout are at the Receiver)
  • 2-wire milliamp signal is nonpolar with protective “steering diodes”

SPECIFICATIONS
Power SupplySenSmart 1100: 9-36 VDC @ 25mA 9-36 VDC @ 25mA
SenSmart 1200, 1300, 1400 and 1500: 3-wire direct “bridge” sensor 2-4.25 VDC sensor specific
Accuracy+/- 1% of full scale range (typical)
Standard OutputSenSmart 1100 : Standard 2-wire 4-20mA current sink . Max loop Resistance is 600 ohms with nominal 24VDC power supply
SenSmart 1200, 1300, 1400 and 1500: 3-wire direct “bridge” sensor output
TempLess than .1% per degree C over ambient temperature range
Housing316 Stainless or aluminum enclosure suitable for Class 1 Groups A,B,C,D; Class 2, Groups E,F,G
Ul94 Poly Black Plastic Enclosure
ApprovalsDivision 1 and 2 Group A,B,C,D Exia. Suitable for Explosion Proof and Intrinsically Safe installations
UL94 Poly Black Plastic Enclosure: Non-Incendive Cl 1 Div 2 Gr ABCD
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    9 Items found.
10-0203
(7043)

RC SYSTEMS  10-0203

RC SYSTEMS Sensor calibration cup adaptor for stainless steel / aluminum sensor heads



$95.71 
CYL-10125000
(1275)

PORTAGAS  CYL-10125000

Calibration Gas Carbon Monoxide (CO) 50 ppm Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-10159000
(318)

PORTAGAS  CYL-10159000

Calibration Gas Carbon Monoxide (CO) 200 ppm Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-10195010
(1282)

PORTAGAS  CYL-10195010

Calibration Gas Carbon Monoxide (CO) 500 ppm Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
10-0552
(7028)

RC SYSTEMS  10-0552

Sample Draw Flow Cell Barrel Adapter for RC Systems Gen I and Gen II 10-0247 Sensor heads(Series 1000, 2000, 3000, 5000 and 6000) gas detectors) 1/8" NPT ports (1 inlet 1 outlet). Used with ST-44 and ST-48 Transmitters.



$213.06 
10-9011-0100P
(7093)

RC SYSTEMS  10-9011-0100P

RC Systems 10-9011/10-9511 Gen I EC Smart Sensor for Series 1000, 2000, 3000 Gas Detectors with ST-48 transmitter, Carbon Monoxide (CO) up to 5000ppm (0-100, 0-250, 0-500, 0-1000, 0-5000)ppm

Configure

$536.36 
90-01
(3243)

RC SYSTEMS  90-01

RC Systems ViewSmart 200 2-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 2 x 3-wire bridge or 2 x 4-20mA input channels board.

Configure

$2,820.78 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
ST-72-02
(6921)

RC SYSTEMS  ST-72-02

RC Systems ViewSmart 6400 Digital Gas Detection CONTROLLER with 16, 32, 48 or 64 channels and LCD display of 320x240 pixels. Centralize display and alarm functions. UL and CSA approved for Class I, Division 2, 2 standard Master/Slave RS485 ports and Modbus TCP Client/Server port with web server included. Standard SPDT 5A relays for HORN and FAULT, plus 3 programmable alarm relays included. NEMA 4X, NEMA 4X Stainless Steel, full 19" Rack mount and NEMA 7 wall-mount options. Optional 4-20mA inputs.

Configure

$12,179.52 
> CARBON MONOXIDE :    36 Items found.
CM-E1
(638)

MACURCO  CM-E1

Macurco CM-E1 Carbon Monoxide gas detector for residential and commercial office environment. Flush or surface mount options, alarm and trouble relays, and 85 dB buzzer. 9-32 VDC input. NFPA 720-2009 and UL 2075 listed. CSFM Approved.



$66.15 
M015-0001-000
(6333)

MPOWER  M015-0001-000

mPower UNI 321 Disposable Single Gas Detector for detection of Carbon Monoxide (CO) 1-500ppm. Up to 36 months of live. Large LCD display will show time remaining or low/high alarm levels when hit, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$108.80 
BWC2-M
(4265)

BW  BWC2-M

BW Clip portable gas detector 2 year maintenance free for Carbon Monoxide CO. Low alarm set between 25ppm and 50 ppm, High alarm set between 50ppm and 200 ppm. UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.

M001-0023-000
(5994)

MPOWER  M001-0023-000

mPower UNI MP100 Portable Single Gas Detector for detection of Carbon Monoxide (CO) 0-500ppm to 0-2000ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$134.40 
PPS+-CO
(6813)

PROSENSE  PPS+-CO

Prosense PPS+-CO Addressable Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300ppm, 0-500ppm or 0-1000ppm. ABS Plastic housing. Modbus RS485 RTU output. IP54. For Parking Garages and Tunnels.

Configure

$214.50 
PPS-RCO
(6811)

PROSENSE  PPS-RCO

Prosense PPS-RCO Addressable Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300ppm. ABS Plastic housing. Relay outputs. IP54. For Parking Garages and Tunnels.



$214.50 
TX1-1
(5965)

INDUSTRIAL SCIENTIFIC  TX1-1

Industrial Scientific Tango TX1 Gas Detector for Carbon Monoxide (CO) 1-1000 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

BWC2R-M
(5149)

BW  BWC2R-M

BW Clip Real Time portable gas detector with 2 year maintenance free for Carbon Monoxide (CO). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

BWC3R-M
(5153)

BW  BWC3R-M

BW Clip Real Time portable gas detector with 3 year maintenance free for Carbon Monoxide (CO). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

LC-1112-A-000-1
(2913)

INTEC  LC-1112-A-000-1

Intec Controls PolyGard LC-1112 V3 Analog Gas Transmitter for Carbon Monoxide (CO) 0-150 / 0-200 / 0-250 / 0-300 ppm. 1 4-20mA & 2-10V analog output. Wall mounted. NEMA 4X Enclosure. UL Listed and CSA Certified.

Configure

$327.00 
BWS1-ML-Y
(6383)

BW  BWS1-ML-Y

BW Solo Serviceable Single-gas Detector for Carbon Monoxide (CO) 0-2000 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PC3-4424
(6802)

PROSENSE  PC3-4424

Prosense PC3-4424 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$463.32 
CM-6
(637)

MACURCO  CM-6

MACURCO CM-6 low voltage gas detector, controller and transducer for Carbon Monoxide (CO) 0-200 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1. Optional LADBS approval.

Configure

$481.90 
CM-12
(3415)

MACURCO  CM-12

MACURCO CM-12 line voltage Gas Detector, controller and transducer for Carbon Monoxide (CO) 0-200 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$494.01 
P-4434
(6777)

PROSENSE  P-4434

Prosense P-4434 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with ranges 0-300ppm to 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$540.54 
364-455-01-365-796-110100
(6150)

DELPHIAN  364-455-01-365-796-110100

Delphian GazTell Fixed Point Electrochemical Gas Detector for Carbon Monoxide (CO) 0-100, 0-300 or 0-1000 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

SPSTAXC1
(1477)

HONEYWELL  SPSTAXC1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Carbon Monoxide (CO) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-200 ppm, 0-500 ppm)

Configure

$719.15 
PQN-4434-1/2
(6949)

PROSENSE  PQN-4434-1/2

Prosense PQN-4434 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with ranges 0-300ppm, 0-500ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$720.72 
OI-6000-EC-CO-X-R_-DC-C
(6832)

OTIS  OI-6000-EC-CO-X-R-DC-C

Otis Instruments OI-6000 Gas Leak Detector with electrochemical sensor for Carbon Monoxide (CO) 0-1000ppm. Non explosion proof. Wired power (3-Wire) (12 to 35 VDC) with 4-20 mA analog, RS-485 Modbus and 2 relay outputs. 3 Push-Button Interface. IP 66/67. Optional radio. UL Approved.

PQD-4434-1/2
(6738)

PROSENSE  PQD-4434-1/2

Prosense PQD-4434 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with ranges 0-300ppm, 0-500ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$875.16 