RC Systems SenSmart 1100 gas detector for Carbon Monoxide (CO) 0-100 ppm to 0-5000 ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20 mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class I Div 1 (Explosion Proof).

4-20 mA   CSA   UL   DIV 1

1100ALD-109011/0100P-L0   
1,338.96

Sensor Range
Enclosure Type
Splash Guard

   3 Weeks  ]
20 Variants of base SKU

The RC Systems SenSmart 1100/1200/1300 are complete 2 or 3 wire Gas Detectors available in UL94 flame retardant plastic, or, Class 1 Div 1 316 stainless steel sensor head enclosures These easy-to-install and maintain gas detectors must be connected to an R. C. Systems single or multi-channel receiver to add user calibration and readout functions.

SenSmart 1100 utilizes our electrochemical temperature controlled SMART sensors to transmit O2, H2S, SO2, Cl2, HF, HCL, NO2 (to name a few) 2-wire 4-20mA gas values to R. C. Systems single and multi-channel receivers.

The SenSmart 1200, 1300, 1400 and 1500 utilize our 3-wire direct “bridge” sensor input, including catalytic, PID and infrared, to detect methane, propane, VOC’s, benzene, CO2 and many other compounds. The bridge output is compatible with R. C. Systems single and multi-channel receivers.

Improved design and direct replacement of the GDS Corp. GDS-49

FEATURES HIGHLIGHT
  • Field swappable sensor module. Range and target gas configured on sensor module
  • Improves system noise immunity because low level sensor signals are protected within the sensor head
  • Industry standard 4-20mA signal may be transmitted thousands of feet on 2-wires
  • 316 SS model is suitable for Class 1 Div 1 hazardous areas.
  • Missing or failed sensor forces <2mA FAULT signal
  • Compatible with 1, 2, 4, 16 and 64 channel Receiver/Controllers (user calibration & readout are at the Receiver)
  • 2-wire milliamp signal is nonpolar with protective “steering diodes”

SPECIFICATIONS
Power SupplySenSmart 1100: 9-36 VDC @ 25mA 9-36 VDC @ 25mA
SenSmart 1200, 1300, 1400 and 1500: 3-wire direct “bridge” sensor 2-4.25 VDC sensor specific
Accuracy+/- 1% of full scale range (typical)
Standard OutputSenSmart 1100 : Standard 2-wire 4-20mA current sink . Max loop Resistance is 600 ohms with nominal 24VDC power supply
SenSmart 1200, 1300, 1400 and 1500: 3-wire direct “bridge” sensor output
TempLess than .1% per degree C over ambient temperature range
Housing316 Stainless or aluminum enclosure suitable for Class 1 Groups A,B,C,D; Class 2, Groups E,F,G
Ul94 Poly Black Plastic Enclosure
ApprovalsDivision 1 and 2 Group A,B,C,D Exia. Suitable for Explosion Proof and Intrinsically Safe installations
UL94 Poly Black Plastic Enclosure: Non-Incendive Cl 1 Div 2 Gr ABCD
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    11 Items found.
10-0203
(7043)

RC SYSTEMS  10-0203

RC SYSTEMS Sensor calibration cup adaptor for stainless steel / aluminum sensor heads



$95.71 
10125000
(1275)

PORTAGAS  10125000

Calibration Gas Carbon Monoxide (CO) 50 ppm Balance Air 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$135.15 
10159000
(318)

PORTAGAS  10159000

Calibration Gas Carbon Monoxide (CO) 200 ppm Balance Air 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$135.15 
10195010
(1282)

PORTAGAS  10195010

Calibration Gas Carbon Monoxide (CO) 500 ppm Balance Air 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$135.15 
10-0552
(7028)

RC SYSTEMS  10-0552

Sample Draw Flow Cell Barrel Adapter for RC Systems Gen I and Gen II 10-0247 Sensor heads(Series 1000, 2000, 3000, 5000 and 6000) gas detectors) 1/8" NPT ports (1 inlet 1 outlet). Used with ST-44 and ST-48 Transmitters.



$213.06 
10-0248A
(7300)

RC SYSTEMS  10-0248A

RC Systems SenSmart 1100 Stainless Steel Smart Sensor head/transmitter with 4-20mA Output for Gen I Electrochemical 10-90XX, and 10-95XX sensors. No Junction Box.



$438.46 
10-9011-0100P
(7093)

RC SYSTEMS  10-9011-0100P

RC Systems 10-9011/10-9511 Gen I EC Smart Sensor for Series 1000, 2000, 3000 Gas Detectors with ST-48 transmitter, Carbon Monoxide (CO) up to 5000ppm (0-100, 0-250, 0-500, 0-1000, 0-5000)ppm

Configure

$512.91 
90-01
(3243)

RC SYSTEMS  90-01

RC Systems ViewSmart 200 2-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Div 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 2 x 3-wire bridge or 2 x 4-20 mA input channels board.

Configure

$2,820.78 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Div 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20 mA input channels board.

Configure

$3,525.97 
ST71P-1
(7026)

RC SYSTEMS  ST71P-1

RC Systems ViewSmart 1600+ 8 or 16-Channel Gas Detector Integral Alarm Controller with standard 5x 5A SPDT relays, 2 standard Master/Slave RS485 ports and Modbus TCP Client/Server port with web server included in standard CSA approved, Class I, Div 2 - NEMA 4X non-metallic enclosure. 24VDC power supply. Optional 4-20 mA inputs, 4-20 mA outputs, discrete and programmable alarm relays channels boards.

Configure

$6,217.56 
ST-72-02
(6921)

RC SYSTEMS  ST-72-02

RC Systems ViewSmart 6400 Digital Gas Detection CONTROLLER with 16, 32, 48 or 64 channels and LCD display of 320x240 pixels. Centralize display and alarm functions. UL and CSA approved for Class I, Div 2, 2 standard Master/Slave RS485 ports and Modbus TCP Client/Server port with web server included. Standard SPDT 5A relays for HORN and FAULT, plus 3 programmable alarm relays included. NEMA 4X, NEMA 4X Stainless Steel, full 19" Rack mount and NEMA 7 wall-mount options. Optional 4-20 mA inputs.

Configure

$12,179.52 
> CARBON MONOXIDE :    38 Items found.
CM-E1
(638)

MACURCO  CM-E1

Macurco CM-E1 Carbon Monoxide gas detector for residential and commercial office environment. Flush or surface mount options, alarm and trouble relays, and 85 dB buzzer. 9-32 VDC input. NFPA 720-2009 and UL 2075 listed. CSFM Approved.



$67.83 
C2-M
(4265)

BW  C2-M

BW Clip portable gas detector 2 year maintenance free for Carbon Monoxide CO. Low alarm set between 25ppm and 50 ppm, High alarm set between 50ppm and 200 ppm. UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.

70-2900-0500-1
(7302)

AIMSAFETY  70-2900-0500-1

AimSafety PM100 Portable Gas Detector (Two Year Disposable) for Carbon Monoxide (CO) 0-500 ppm. LCD display. Audible, visual and vibrating alarms. IP67. UL & CSA Class I Div 1, Div 2, ATEX, IECEx, INMETRO.



$120.00 
M015-0001-000
(6333)

MPOWER  M015-0001-000

mPower UNI 321 Disposable Single Gas Detector for detection of Carbon Monoxide (CO) 1-500ppm. Optional 24 or 36 months of life. Large LCD display will show time remaining or low/high alarm levels when hit, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$122.98 
PPS+-CO
(6813)

PROSENSE  PPS+-CO

Prosense PPS+-CO Addressable Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300ppm, 0-500ppm or 0-1000ppm. ABS Plastic housing. Modbus RS485 RTU output. IP54. For Parking Garages and Tunnels. PPS+ detectors cannot be used either stand alone or integrated to 3rd party systems, work with PPS Manager PPS-KP alarm panel only.

Configure

$134.49 
M001-0023-000
(5994)

MPOWER  M001-0023-000

mPower UNI MP100 Portable Single Gas Detector for detection of Carbon Monoxide (CO) 0-500ppm to 0-2000ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$153.08 
TX1-1
(5965)

INDUSTRIAL SCIENTIFIC  TX1-1

Industrial Scientific Tango TX1 Gas Detector for Carbon Monoxide (CO) 1-1000 ppm. DualSense Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

BWC2R-M
(5149)

BW  BWC2R-M

BW Clip Real Time portable gas detector with 2 year maintenance free for Carbon Monoxide (CO). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

BWC3R-M
(5153)

BW  BWC3R-M

BW Clip Real Time portable gas detector with 3 year maintenance free for Carbon Monoxide (CO). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

CX-6-CO
(7310)

MACURCO  CX-6-CO

Macurco CX-6-CO low voltage Gas Detector, Controller and Transducer for Carbon Monoxide (CO) 0-200 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC. power ETL Listed to UL 61010-1, UL 2075 LADBS approval.

Configure

$362.25 
SV-4404
(7376)

PROSENSE  SV-4404

Prosense SafeVader SV-4404 Fixed Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300 ppm to 0-5000 ppm. 4-20 mA Analog, Modbus RS485 RTU and relay outputs (Alarm1, Alarm2, Fault). 12 to 28VDC. ABS Plastic enclosure. IP54.

Configure

$366.92 
CX-12-CO
(7311)

MACURCO  CX-12-CO

Macurco CX-12-CO low voltage Gas Detector, Controller and Transducer for Carbon Monoxide (CO) 0-200 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC. power ETL Listed to UL 61010-1, UL 2075 LADBS approval.

Configure

$400.20 
PC3-4424
(6802)

PROSENSE  PC3-4424

Prosense PC3-4424 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$421.40 
BWS1-ML-Y
(6383)

BW  BWS1-ML-Y

BW Solo Serviceable Single-gas Detector for Carbon Monoxide (CO) 0-2000 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

CM-6
(637)

MACURCO  CM-6

MACURCO CM-6 low voltage gas detector, controller and transducer for Carbon Monoxide (CO) 0-200 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1, UL 2075 LADBS approval.

Configure

$448.50 
CM-12
(3415)

MACURCO  CM-12

MACURCO CM-12 line voltage Gas Detector, controller and transducer for Carbon Monoxide (CO) 0-200 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1, UL 2075 LADBS approval.

Configure

$472.65 
P-4434
(6777)

PROSENSE  P-4434

Prosense P-4434 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with ranges 0-300ppm to 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$564.86 
364-455-01-365-796-110100
(6150)

DELPHIAN  364-455-01-365-796-110100

Delphian GazTell Fixed Point Electrochemical Gas Detector for Carbon Monoxide (CO) 0-100, 0-300 or 0-1000 ppm. 4-20 mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PQN-4434-1/2
(6949)

PROSENSE  PQN-4434-1/2

Prosense PQN-4434 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with ranges 0-300ppm, 0-500ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Marine Bureau Veritas Certification, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$797.98 
SPSTAXC1
(1477)

HONEYWELL  SPSTAXC1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Carbon Monoxide (CO) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20 mA loop output. ATEX Approved. (Optional ranges: 0-200 ppm, 0-500 ppm)

Configure

$827.52 