Notifier Acm-24at | Notifier Onyx Series | Annunciators | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   ACM-24AT

SKU# (6867)
NOTIFIER ACM-24AT
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier ACM-24AT Annunciator for control of up to 24 NOTIFIER ONYX Series Intelligent Fire Alarm Control Panels, Network Control Annunciators or Addressable Panels. 24 VDC. Includes 24 yellow Trouble LEDs, 24 momentary touch-pad switches, a System Trouble LED, an On-Line/Power LED, and a local piezo sounder.

Please Email us your request for quote   

   4 Weeks  ]

The ONYX® Series ACS Annunciators provide a modular line of products for annunciation and control of the NOTIFIER ONYX® Series Intelligent Fire Alarm Control Panels, Network Control Annunciators, and NOTIFIER’s legacy addressable panels. The ACS line provides arrays of LEDs to indicate point status and, in some versions, switches to control the state of output circuits. These ACS units use a serial interface and may be located at distances of up to 6,000 feet (1,828.8 meters) from the panel.

Features
  • Speaker control mode for use with XPIQ and the following panels: NFS2-3030, NFS2-640, NFS-320(C) and NFS-320SYS. Enables the ACS to control operation of groups of multi-channels mapped to groups of multi-speakers.
  • Compatible with existing annunciators.
  • Color-programmable LEDs.
  • On-board end-of-line resistors can be enabled/disabled by setting a switch.
  • Alarm/Circuit On and Trouble LED per-point option or more dense Alarm-only option.
  • Touch-pad control switch option for remote control of system relays; or silence, reset, and evacuate.
  • LEDs may be programmed to display status of indicating circuits or control relays as well as system status conditions.
  • System Trouble LED indicator.
  • On-Line/Power LED indicator.
  • Alarm and trouble resound with flash of new conditions.
  • Local sounder for both alarm and trouble conditions with silence/acknowledge button (program options).
  • May be powered by 24 VDC from the panel or by remote power supplies.
  • Microprocessor-controlled electronics, fully supervised.
  • Slip-in custom labels, lettered with standard typewriter or LabelEase program.
  • Plug-in terminal blocks for ease of installation and service.
Construction

The ACS modules are provided in two basic controller modules, each with its expander module. The ACM-24AT provides 24 annunciation and control points per module, each with a red, green, or yellow Alarm/Circuit On LED, a yellow Trouble LED, and a touch-key switch. The ACM-48A provides 48 annunciation points per module, each with a red, green, or yellow Alarm/Circuit On LED (for annunciating control relays, the LED indicates ON/OFF).

On the ACM-24AT, each LED point is individually color-programmable. On ACM-48A, each column of 24 LED points can be color-configured using a DIP switch.

Temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the useful life of the system’s standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F).

Installation

The ACS Series annunciator and control subsystems use modular hardware assemblies which allow the custom configuration of the annunciator panel to fit the individual job requirements.

Standard backboxes and mounting hardware schemes, including special remote cabinets, allow the annunciators to be constructed and configured with other system components.

When used with the NFS2-3030, NFS2-640, NFS-320 or legacy panels, the ACS modules can be used for manual selection of speaker and telephone circuits. In this application, they are typically mounted in the main control near the microphone and telephone handset.

For remote annunciation applications, the modules are typically mounted in special ABF or ABS boxes. Control switch key locks (AKS-1B) are available.

Communication between the ACS Series annunciators and the host Fire Alarm Control Panel is made through an EIA-485 multi-drop loop, eliminating the need for costly wiring schemes. Four wires are required, two for the EIA-485 communications (twisted pair), and two for 24 VDC regulated power.

Retrofit of ACS Series annunciators into existing systems is easily accomplished. Software may require upgrading, and some legacy panels may require an interface board.

All field-wiring terminations use removable, compression-type terminal blocks for ease of installation, wiring, and circuit testing.

Operation

The ACS Series annunciator and control system provides the NOTIFIER system with up to 32 remote serially connected annunciators, each with a capacity of 96 points, for a total capacity of 3072 points (subject to the capability of the FACP). The NFS2-3030 and NCA-2 are capable of using the full 96 points.

Local or remote power supplies and serial communications allow the ACS to be located virtually anywhere in the protected premises.

On NFS-320, NFS2-640, NFS2-3030, NCA-2 and the legacy panels, system alarm and/or trouble conditions may be annunciated on a per-point basis, or in a grouped or zone configuration.

Control of system operational controls, such as Signal Silence, System Reset, and local annunciation controls (such as Local Acknowledge and Lamp Test) may be accomplished through the module’s rubber keypad.

The Annunciator Control Module-24AT contains 24 color-programmable (red/green/yellow) Active and 24 yellow Trouble LEDs, 24 momentary touch-pad switches, a System Trouble LED, an On-Line/Power LED, and a local piezo sounder with a silence/acknowledge switch for audible indication of alarm and trouble conditions. Includes instructions. 8.375" (21.27 cm) high; 4.375" (11.11 cm) wide.

Agency Listings and Approvals

The listings and approvals below apply to the ACM/AEM-24AT and the ACM/AEM-48A. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing sta- tus.

  • UL: S635
  • ULC: S527-11
  • FDNY: COA #6212 (NFS2-640), COA #6211 (NFS2-3030)
  • CSFM: 7120-0028:0156, 7165-0028:0243, 7165-0028:0224
  • FM approved

Export Info
Made inMexico

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    3 Items found.
NCA-2
(3508)

NOTIFIER  NCA-2

Notifier NCA-2 for ONYX Series fire control panels



 
NFS-320
(2039)

NOTIFIER  NFS-320

NOTIFIER by Honeywell ONYX Series NFS-320 Intelligent Addressable Fire Alarm Control Panel. Certified for seismic and marine applications. Supports up to 159 detectors and 159 modules. Standard 80-character display and 6A power supply. Built-in Alarm, Trouble, Security and Supervisory relays, FlashScan network prototol.

CPU2-3030D
(6931)

NOTIFIER  CPU2-3030D

Notifier CPU2-3030D Central processing unit for an NFS2-3030 system. Keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control keypad. Requires an AMPS-24(E) power supply.

> NOTIFIER ONYX SERIES :    6 Items found.
NCA/640-2-KIT
(3510)

NOTIFIER  NCA/640-2-KIT

Notifier NCA/640-2 kit for ONYX Series fire control panels



 
NCA-2RETRO
(3509)

NOTIFIER  NCA-2RETRO

Notifier NCA-2RETRO kit for ONYX Series fire control panels



 
ISO-X
(3235)

NOTIFIER  ISO-X

Notifier ISO-X Fault Isolator Module for Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). Powered by SLC loop. High noise immunity. UL, FM, CSFM, MEA and BSA Approved.



 
(7025)

NOTIFIER  DP-GDIS1

Notifier DP-GDIS1 Graphic Annunciator Dress Plate to mount the 10" graphic display and ONYX Series Annunciators in a CAB-4 Series cabinet.

NCD
(7024)

NOTIFIER  NCD

Notifier NCD Network Control Display annunciator for NOTIFIER INSPIRETM and ONYX series fire alarm control panels. 24 VDC. USB C, USB Micro, and USB A. Trouble Relay.



 
CPU2-640
(6868)

NOTIFIER  CPU2-640

Notifier CPU2-640 Central processing unit with integral 3.0 A (6.0 A in alarm) power supply for an NFS2-640 system. Includes control panel factory-mounted on a chassis, one Signaling Line Circuit (expandable to two) and documentation kit.

Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.