Honeywell Fsl100-uvir | Ultraviolet/infrared | Flame Detectors | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   FSL100-UVIR

HONEYWELL FSL100-UVIR
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell FSL100-UVIR Flame Detector for robust, fast, and reliable detection of hydrocarbon and non-hydrocarbon fires in indoor/outdoor environments and potentially explosive atmospheres. Relay and mA outputs. GRP housing. EN54-10 and FM3260 approvals. IP65.

FSL100-UVIR   
2,268.94

Color
Swivel mount

   12 Weeks  ]

The FSL100 Series of flame detectors from Honeywell delivers robust, fast, and reliable detection of flaming fires in a wide range of applications.

The range consists of UV, UV/IR and IR3 flame detectors. All utilize sophisticated sensing and signal analysis to detect fires quickly while also rejecting false alarms.

The FSL100 may be small and lightweight for easy installation but it is designed to work in tough indoor/outdoor environments, as well as potentially explosive atmospheres.

Suitable for Many Applications
  • UV, UV/IR and IR3 available
  • Hydrocarbon and non-hydrocarbon sources
  • Use in potentially explosive atmospheres
  • Indoor and outdoor operation
  • High visibility red or discrete white models available
Great Performance
  • Approved to EN54-10 and FM3260 flame detector standards
  • Comprehensive automatic self test
  • Remote manual self test option
Fast & Reliable
  • High speed sensors and microprocessor
  • Sophisticated analysis algorithms
  • Continuous health monitoring
  • False alarm rejection
Reduced Life Cost
  • Long life elements
  • Pressure compensation to avoid contamination
  • 2 year warranty
  • Buy with confidence
Ease of Installation and Use
  • Relay and mA outputs as standard
  • Lightweight GRP housing
  • Pre-formed knockouts
  • Optional swivel mounting bracket
  • Long range test lamp available
FSL100-UV/IR
  • Analysis of the flame flicker-frequency for improved false alarm rejection
  • Dual sensing methodology enables a wide range of hydrocarbon and non-hydrocarbon fires to be effectively detected
  • Good resistance against the influences of:
    • Direct and reflected sunlight
    • Artificial light, such as fluorescent tubes and glass covered halogen lamps
    • Arcs and electric discharges (static or from e.g. electric motors)
    • The radiation from electric welding provided that the electric welding takes place at a distance more than 10 feet from the flame detector (a welding rod contains organic compounds which may produce a small flame)

SPECIFICATIONS: FSL100 SERIES FLAME DETECTORS
FSL100 Flame Detector typesFSL100-UV, FSL100-UVIR and FSL100-IR3; Choice of red or white housings
Range110 ft /35 m (IR3), 25 m/80 ft (UV, UV/IR) alarming within 10 seconds to a 1 ft2(0.1 m 2 )n-heptane fire
Cone of vision90 ̊minimum horizontal and vertical
Power10-28 VDC (12-24 VDC nominal)
Local LEDsContinuous green: normal operation
Continuous yellow: fault
Flashing yellow: Fault and guide to repeat self-test after a self-test failure
Continuous red: alarm
Current outputStandard available 4–20 mA (stepped, sinking, non-isolated)
0 mA power fault / microprocessor fault
2 mA optical fault
4 mA normal operation
>20 mA alarm
Relay output:
- Alarm relay
- Fault relay
De-energized during normal operation, no alarm, SPDT, 30 VDC – 2 A, 60 W max. Energised during normal operation, no fault, SPDT, 30 VDC – 2 A, 60 W max
Cable gland & terminalsCable entry M20 clearance. Supplied with gland suitable for cable diameter from 0.2” (5.5mm) to 0.5”(13mm). Terminals suitable for 0.5mm 2 (20AWG) to 1.5mm 2 (15AWG) wire
Start up times<10 sec
Alarm response time8 to 30 sec
Alarm output settingsSelectable LEDs and relays latching/non-latching; factory setting: latching
Automatic & manual Self-TestAutomatic Sensor Test (built in Self-Test) and manual Self-Test
Operating current normal25 mA at 24 VDC
Current in alarm, at 24 VDC±75 mA at 24 VDC
Connections to:Fire control panels using end of line (EOL) and alarm resistors (current increase)
Devices that operate via relay switched outputs
PLCs with 4–20 mA inputs
End of line and alarm resistorTo be adjusted to the fire control panel; free terminals are dedicated to the resistors
Note: the alarm and EOL resistor must be rated 2 W min. each and the total power dissipation of both alarm and EOL resistor should not exceed 2 W
HousingGlass Reinforced Polyester (GRP), Non-incendive. UV resistant, Self-Extinguishing V–0 (UL-94)
Swivel MountPA66, UV resistant; Stainless Steel fixings; 280 g (0.62 lb)
Pressure compensating elementPCE (Pressure Compensating Element) avoids moisture build-up in the detector housing due to changes in ambient air-pressure
Dimensions4.9 x 3.15 x 2.25 in (125 x 80 x 57 mm)
Weight1.05 lb (465 g)
Ingress protectionIP65
Temperature, operating–40 ̊F to +158 ̊F (–40 ̊C to +70 ̊C)
Temperature, ambient ATEX and FM class 3611–13 ̊F to +158 ̊F (–25 ̊C to +70 ̊C)
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)90318099

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    3 Items found.
FSL100-TL
(6773)

HONEYWELL  FSL100-TL

Honeywell FSL100 test lamp flame simulator with universal charger and carrying case, non EX.

Configure

$1,861.59 
FSL100-IR3
(6772)

HONEYWELL  FSL100-IR3

Honeywell FSL100-IR3 Flame Detector for robust, fast, and reliable detection of liquid hydrocarbon and dirty fires in indoor/outdoor environments and potentially explosive atmospheres. Relay and mA outputs. GRP housing. EN54-10 and FM3260 approvals. IP65.

Configure

$2,403.53 
FSL100-UV
(6770)

HONEYWELL  FSL100-UV

Honeywell FSL100-UV Flame Detector for robust, fast, and reliable detection of hydrocarbon or hydrogen fires in indoor/outdoor environments and potentially explosive atmospheres. Relay and mA outputs. GRP housing. EN54-10 and FM3260 approvals. IP65.

Configure

$2,433.66 
> ULTRAVIOLET/INFRARED :    5 Items found.
100-0003-01
(4719)

ESP SAFETY  100-0003-01

ESP Safety IPES-IR/UV Infrared/Ultraviolet Flame Detector for detection of oil and petrochemical product fires. 4.2 to 4.6 microns (infrared) and 180 to 250 nanometers (ultraviolet) ranges. 90 degree field of view. RS-485, Modbus RTU, 4-20mA and relay outputs. Color status LED. Explosion-proof Housing. Designed for Class I, Division 1, Group B, C & D. ATEX certified, SIL3 Rated. Includes protective visor, stainless steel mounting bracket and hardware.

Configure

$1,350.00 
20/20ML-11SF
(2935)

SPECTREX  20/20ML-11SF

SPECTREX Sharp Eye 20/20ML Mini UV/IR Flame Detector for detection of gasoline, n-heptane, diesel, jp5, kerosene, alcohol, ,IPA, methanol, methane, propane, hydrogen, silane, polypropilene and paper fires. Low cost, stainless steel enclosure, compact and lightweight. Highly resistant to harsh environments, immune to false alarms and designed for OUTDOOR or INDOOR applications. 2 Relays (Alarm and Fault), 0-20mA (sink or source) and compatible with RS-485 Modbus. Stainless steel housing. Available Approvals: FM (Functionality, No Ex)

Configure

$2,581.22 
40/40C-L4B-6-41-AC-N-7
(6860)

SPECTREX  40/40C-L4B-6-41-AC-N-7

SPECTREX SharpEye 40/40C-L4B Ultraviolet/Infrared UV/IR 4.5um Flame Detector. Detects hydrocarbon-based fuel and gas fires with proven immunity to false alarms. 24 Vdc. Includes HART capability, Automatic Built-In-Test (BIT), 3 Relays for alarm, fault and auxiliary and RS-485 Modbus outputs. Heavy duty copper free aluminum housing. IP66 and IP68. NEMA® 250 6P. ATEX, IECEx, FM, CSA and SIL3 Approved. Capable for Class I Div 1 & 2.

Configure

$3,784.92 
40/40C-LB-6-41-AC-N-7
(6859)

SPECTREX  40/40C-LB-6-41-AC-N-7

SPECTREX SharpEye 40/40C-LB Ultraviolet/Infrared Flame UV/IR Detector. Detects flames with a large variety of hazardous sources (hydrocarbon, hydroxyl, hydrogen, metal, inorganic). 24 Vdc. Includes HART capability, Automatic Built-In-Test (BIT), 3 Relays for alarm, fault and auxiliary and RS-485 Modbus outputs. Heavy duty copper free aluminum housing. IP66 and IP68. NEMA® 250 6P. ATEX, IECEx, FM, CSA and SIL3 Approved. Capable for Class I Div 1 & 2.

Configure

$3,784.92 
FS20X-211-212
(2986)

HONEYWELL  FS20X-211-212

Honeywell Fire Sentry FS20X Multi-Spectrum (UV/Dual IR/VIS) Fire and Flame Detector for hydrocarbon and non-hydrocarbonfuel fires in all industrial enviromental conditions. 90° field of view. RS-485 MODBUS communication and 0-20 mA stepped analog output. Includes fire, fault and auxiliary relays. NEMA 4 & 4X enclosure. IP66. FM, ATEX and CE approvals.

Configure

$3,840.83 