Notifier HPF24S6(C/E) (6 amp) or HPF24S8(C/E) (8 amp) Remote Fire Alarm Power Supply with battery charger for 12 or 24 volt fire alarm control panels (FACP). 4 configurable outputs. UL, ULC and NFPA listed. *** Phased Out Replaced by HPF-PS6***

Inquiry

The HPF24S6(C/E) and HPF24S8(C/E) are compact, cost-effective, 6-amp or 8-amp remote power supplies with battery charger.

They may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA requirements and NAC synchronization) or auxiliary power to support 24-volt system accessories. The supply provides regulated and filtered 24 VDC power to four Notification Appliance Circuits configured as either four Class B (Style Y) or Class A (Style A, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. They also contains a battery charger capable of charging up to 18 Amp Hour batteries.

FEATURES AND BENEFITS
  • Extends and supports power for additional fire alarm devices
  • Instantaneous switchover to standby battery (if equipped) when AC fails, maintaining power to all attached devices without intervention
  • Strobe signal “passes through” allowing syncing of large systems
  • LED lights for quick and easy diagnosis, troubleshooting, and status indication
  • Two outputs can be used for constant power devices such as door holders (power drops upon alarm)
  • Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notification circuit (including unfiltered and unregulated bell power)
  • UL Listed NAC Synchronization using System Sensor®, Wheelock®, or Gentex® (Commander Series) appliances
  • Cascade up to 10 power supplies (four with Gentex) with strobe timing maintained
  • Operates as a sync follower or a sync generator (default)
  • Contains two, fully-isolated input/control circuits (triggered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [standalone mode])
  • Configured to internally house addressable SLC control module for alarm activation
  • Four Class B (Style Y) or four Class A (Style Z) (with ZNAC-4 Module) Notification Appliance Circuits
  • 6.0A or 8A (depending on model) full load output (3.0 A maximum per circuit) in NAC expander mode (UL 864)
  • 4.0A or 6.0A continuous output in stand-alone mode (UL 1481)
  • In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable or a mix of two and two
  • Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power
  • Power-limiting technology meets UL power-limiting requirements
  • Form-C normally-closed trouble relay
  • Fully supervised power supply, battery and Notification Appliance Circuits
  • Selectable earth fault detection
  • AC trouble report selectable for immediate or 8 hour delay
  • Requires input trigger voltage of 9.0 - 32 VDC
  • Self-contained in compact, lockable cabinet (15" [38.1 cm] H x 14.5" [36.8 cm] W x 2.75" [7.0 cm] D)
  • Includes integral battery charger capable of charging up to 18 AH batteries; cabinet capable of housing 7.0 AH batteries
  • Battery charger may be disabled via dip switch for applications requiring larger batteries
  • Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire
  • Power-limiting technology meets UL power-limiting requirements
  • Form-C normally-closed trouble relay
  • Fully supervised power supply, battery and Notification Appliance Circuits
  • Selectable earth fault detection
  • AC trouble report selectable for immediate or 8 hour delay
  • Requires input trigger voltage of 9.0 - 32 VDC
  • Self-contained in compact, lockable cabinet (15" [38.1 cm] H x 14.5" [36.8 cm] W x 2.75" [7.0 cm] D)
  • Includes integral battery charger capable of charging up to 18 AH batteries; cabinet capable of housing 7.0 AH batteries
  • Battery charger may be disabled via dip switch for applications requiring larger batteries
  • Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire
STANDARDS AND CODES
  • NFPA 72 National Fire Alarm Code
  • UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode)
  • UL 1481 Power Supplies for Fire Alarm Systems (standalone mode)
  • CAN/ULC-S527-99
Listings

Listings and approvals below apply to the HPF24S6 and HPF24S8. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL Listed: S6677
  • CAN/ULC Listed: S6677
  • CSFM: 7315-1637:0102
  • FM Approved

Specifications
Primary (AC) Power:HPF24S6/8(C): 120 VAC 60 Hz, 3.2 A maximum
HPF24S6/8E: 220/240 VAC, 50 Hz, 1.6 A maximum
Wire size: minimum 14 AWG (2.0 mm2) with 600V insulation
Control Input Circuit:Trigger Input Voltage: 9.0 to 32 VDC
Trigger Current: 2.0 mA (16 - 32 V)
(per input) 1.0 mA (9 - 16 V)
Trouble Contact Rating:5.0 A at 24 VDC
Auxiliary Power Output:Special Application Power - 500 mA maximum
Output Circuits:+24 VDC filtered, regulated
3.0 A maximum for any one circuit
4.0 A maximum total continuous current for all outputs (Stand-alone mode) for the HPF24S6 and 6A for the HPF24S8
6A or 8A (depending on model) maximum total short-term current for all outputs (NAC Expander mode)
Secondary Power (Battery) Charging Circuit:Supports lead-acid batteries only
Float-charge voltage: 27.6 VDC
Maximum current charge: 1.5 A
Maximum Battery capacity: 18 AH
> NOTIFIER :    43 Items found.
PF24V
(3237)

NOTIFIER  PF24V

Notifier PF24V ExitPoint Directional Sounder with Voice Messaging designed for open areas, corridors or stairs. Reduces evacuation times up to 75%. 24VDC. UL, FM, CSFM and MEA Approved.



 
BAT-1270-BP
(6944)

NOTIFIER  BAT-1270-BP

Notifier BAT-1270-BP rechargeable battery. 12VDC. 7 AH. 5-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-12550
(6943)

NOTIFIER  BAT-12550

Notifier BAT-12550 rechargeable battery. 12VDC. 55 AH. Overcharge protected. ABS high-impact case.



 
BAT-12260-BP
(6941)

NOTIFIER  BAT-12260-BP

Notifier BAT-12260-BP rechargeable battery. 12VDC. 26 AH. 2-unit bulk pack, Overcharge protected. ABS high-impact case.



 
ISO-6
(6934)

NOTIFIER  ISO-6

Notifier ISO-6 Six Fault Isolator Module for Notifier Fire Alarm Control Panels (FACPs). Powered by SLC loop. Class B isolator circuits. UL, FM, CSFM Approved.



 
LDM-32
(6870)

NOTIFIER  LDM-32

Notifier LDM-32 Lamp Driver Module for annunciation and control of NOTIFIER Intelligent Fire Alarm Control Panels. Up to 32 alarm indications. 24 VDC. EIA-485 interface. UL, ULC, MEA, CSFM and FM Listed.



 
BAT-12120-BP
(6940)

NOTIFIER  BAT-12120-BP

Notifier BAT-12180-BP rechargeable battery. 12VDC. 12 AH. 4-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-1250-BP
(6942)

NOTIFIER  BAT-1250-BP

Notifier BAT-1250-BP rechargeable battery. 12VDC. 5 AH. 10-unit bulk pack, Overcharge protected. ABS high-impact case.



 
XP6-R
(6930)

NOTIFIER  XP6-R

Notifier by Honeywell XP6-R(A) Six Relay Control Module with Form-C Relays. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP6-C
(5122)

NOTIFIER  XP6-C

Notifier XP6-C Six Circuit Supervised Control Module for horns, strobes or bells that require an external power supply. Short-circuit-protection. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP10-M
(3724)

NOTIFIER  XP10-M

Notifier XP10-M Ten Input Monitor Module for intelligent alarm systems. Up to 10 addresable Class B or 5 addressable Class A devices. SLC inputs. Green LED indicators. Flexible mounting options. FlashScan or CLIP operation. UL Listed. CSFM, FM, MEA and MSTM approved.



 
PSE-6
(6924)

NOTIFIER  PSE-6

Notifier PSE-6 (6 amp) or PSE-10 (10 amp) 24 VDC Remote Power Supply Expander with battery charger for 12 or 24 volt alarm control panels (FACP). Up to 7 outputs. UL, ULC, CSFM and FM listed.

APS2-6R
(6938)

NOTIFIER  APS2-6R

Notifier APS2-6R 6.0 Amp Auxiliary Power Supply for the Onyx Series control panels. 150 watt. 24 VDC. SLC circuit. UL, FM and CSFM listed.

BAT-121000
(6939)

NOTIFIER  BAT-121000

Notifier BAT-121000 rechargeable battery. 12VDC. 100 AH. Overcharge protected. ABS high-impact case.



 
NCM-F
(3507)

NOTIFIER  NCM-F

Notifier NCM-F or NCM-W network communication module for NOTIFIER Intelligent Fire Alarm Control Panels and Annunciators. Fiber optic or twisted-pair wire connection. 24 VDC.

HPFF12
(6600)

NOTIFIER  HPFF12

Notifier HPFF12(E) 12 Amp and 24 Volt Power Supply to extend the power of existing Notification Appliance Circuits (NACs) or provide power for auxiliary devices. 4 NAC and 1 aux outputs. 8 status LEDs. UL, CSFM and FM listed.

KDM-R2
(6932)

NOTIFIER  KDM-R2

Notifier KDM-R2 Keyboard Display Module for CPU2-640. 80 character display and QWERTY programming keypad included.



 
ACPS-610
(6936)

NOTIFIER  ACPS-610

Notifier ACPS-610 Addressable Charger/Power Supply. Provides 6 amps of shared power to four outputs or 10 amps as an external battery charger. SLC circuit. UL, ULC, CSFM and FM listed.

AMPS-24
(6937)

NOTIFIER  AMPS-24

Notifier AMPS-24 Addressable Power Supply for NFS-3030, NFS2-3030 and NCA-2. Charges 7 AH to 200 AH batteries. SLC circuit. UL, ULC, CSFM and FM listed.

LEM-320
(6872)

NOTIFIER  LEM-320

Notifier LEM-320 Loop Expander Module for NOTIFIER’s ONYX Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.



 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.