Honeywell Spxcdulnfx | Lel Catalytic Bead | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   SPXCDULNFX

HONEYWELL SPXCDULNFX
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell XCD Sensepoint Gas Detector, CATALYTIC BEAD combustible 0-100% LEL (Lower Explosive Limit) Methane CH4 (LNG-natural gas), Propane C3H8 (LPG), Butane C4H10, Pentane, Hexane, Ethanol, Hydrogen with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%, can be calibrated to several other combustible gases. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

SPXCDULNFX   
1,373.95

Modbus RTU
Enclosure
Agency Approval
Entry
Sunshade/Deluge Protection
Calibration 0-100% LEL
Custom Tag
Junction Box

   In Stock  ]

Standard configurations typically available in In Stock:
SPXCDULNFX    SPXCDULNFX-???    SPXCDULNFX-???    SPXCDULNFX-???-TAG    SPXCDULNFX-TAG
16 Variants of base SKU
XCD normal display (green) XCD Display in Fault/Warning (Yellow) XCD display in Alarm (Red)
Normal Fault/Warning Alarm
FEATURES

One-Stop Shop
  • Flammable (catalytic or infrared), toxic and oxygen versions available
  • New and retrofit applications
  • Suitable for indoor or outdoor use
  • Stainless steel or aluminium explosion-proof housing options
  • IP66 as standard
Proven and Reliable Sensor Technology
  • SurecellTM electrochemical sensors
  • Reflex® sensor health check
  • Poison immune infrared sensors
  • Poison resistant catalytic bead sensors
  • Long life sensors
Global Approvals
  • US and Latin America, European, Canadian and Asian
  • Compliant with UL, INMETRO, ATEX, IECEx, CSA, KTL, PA, GB and CCCF standards
Easy to Use
  • User friendly and intuitive tri-colour backlit display with digits, bar graph and icons
  • Fully configurable via magnetic switches
  • Selectable sink or source 4-20mA output
  • Auto-inhibit during maintenance
  • MODBUS communications for remote diagnostics/configuration
Cost Effective
  • Common transmitter platform
  • Minimal training required
  • Reduced spares
  • Non-intrusive, one-man operation
  • Plug-in sensor replacement
  • MODBUS multi drop option offers cabling savings
Simple Installation
  • Plug-in display module removes to give access to terminal area
  • Integral mounting bracket
  • 2 x M20 or 3⁄4” NPT cable/conduit entries (certification dependent)
  • Removable plug/socket type terminal blocks for ease of wiring
  • Sink/source switch to suit preferred wiring topology
Range of Optional Accessories
  • Remote sensor gassing kit
  • Duct mounting kit
  • Calibration gas flow housing
  • Collecting cone

The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non-intrusive operation and reduces routine maintenance time and costs

Sensepoint XCD ensures easy installation and the fastest routine operation by removing the need for hot work permits in hazardous areas. Using easy to replace plug-in sensors, downtime is also reduced and on-going costs are minimized through the use of poison resistant flammable sensors, poison immune infrared Hydrocarbon sensors and patented SurecellTM toxic sensors and Reflex® sensor health check.

All detectors are supplied pre-configured and include 2 programmable alarm relays, 1 programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable) and Modbus.

A tri-color backlit LCD clearly indicates the unit’s status at a glance, even from a distance. A steady green backlight indicates normal operation, flashing yellow indicates fault and flashing red indicates an alarm.

The scale, range, relay operation, alarm set point and electronic tag number of the detector can be adjusted using the transmitter's LCD and non-intrusive magnetic switches. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance.

Sensepoint XCD has an integral mounting plate for surface mounting or can be mounted to a horizontal or vertical pipe using the optional pipe mounting bracket. Electrical installation can be made using either conduit or cable with suitable mechanical protection. Two M20 or 3⁄4”NPT entries are provided (depending on certification). A weatherproof cap is also included for use in the harshest outdoor conditions. Other optional accessories include a sunshade/deluge protection, duct mounting kit and collecting cone.

TYPICAL APPLICATIONS

  • Industrial manufacturing facilities
  • Power plants
  • Waste water facilities
  • Utilities
  • Food and beverage production
  • Refineries and chemical plants
  • Onshore oil and gas terminals
  • Production platforms
  • Exploration and drilling
Honeywell XCD detector components

1 Cover
2 Display module
3Terminal area
4 Blanking plug
5 Transmitter
6 Plug-in XCD sensor
7 Sensor retaining ring
8 Integral mounting plate
9 Weather protection assembly
10 Cable/conduit entry (x2)
11 Certification label

There are three different types of the XCD transmitter for use with three different families of sensors.

The mV type transmitter is for use with the mV family of XCD sensors including catalytic sensors to detect flammable gases in the range 0-100%LEL and infrared (IR) sensors for detection of Hydrocarbon gases in the range 0-100%LEL, as well as Carbon Dioxide (CO2) in the range 0-2%Vol.

The EC type transmitter is for use with the EC family of XCD sensors including Carbon Monoxide (CO), Hydrogen Sulfide, (H2S), Hydrogen (H2) and Nitrogen Dioxide (NO2).

The Oxygen transmitter is for use with the Oxygen (O2) XCD sensors.

A transmitter can auto-recognize any sensor from within its sensor family. The sensor simply plugs into the bottom of the transmitter and the transmitter automatically configures itself accordingly.

Sensepoint XCD uses three instantly recognizable ‘traffic light’ colors to indicate its status. The large tri-color backlit LCD is steady green to indicate normal operation, flashes yellow to indicate a fault/warning and flashes red to indicate an alarm. This allows anyone in the area to clearly see at a glance the status of any detector. This can be particularly useful to identify detector status if the detector is located in a difficult to access area or if a number of detectors are located in the same area.

Specifications
Gas Flammable 1 to 8
Sensor Family mV
User Selectable Full Scale Range 20.0 to 100.0%LEL
Default Range 100%LEL
Steps 10%LEL
User Selectable Cal Gas Range 30 to 70% of selected full scale range
Default Cal Point 50%LEL
Response Time (T90) Secs <25
Accuracy <+/-1.5%LEL
Min Operating Temperature -20°C / -4°F
Max Operating Temperature 55°C / 131°F
Default Alarm Point A1 20%LEL ▲
Default Alarm Point A2 40%LEL ▲

General Transmitter Specifications
Use 3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from flammable, toxic and Oxygen hazards. Incorporating a transmitter with local display and fully configurable via non-intrusive magnetic switch interface.
Electrical
Input Voltage Range 16 to 32VDC (24VDC nominal)
Max Power Consumption Maximum power consumption is dependent on the type of gas sensor being used. Electrochemical cells = 3.7W, IR = 3.7W and catalytic = 4.9W. Maximum inrush current = 800mA at 24VDC
Current Output Sink or source
Relays 3 x 5A@250VAC. Selectable normally open or normally closed (switch) and energized/de-energised (programmable)
Alarm relays default normally open/de-energized. Fault relay default normally open/energized
Communication RS485, MODBUS RTU
Construction
Material Housing: Epoxy painted aluminium alloy LM25 or 316 stainless steel
Sensor: 316 stainless steel
Weight (approx) Aluminium Alloy LM25: 4.4lbs
316 Stainless Steel: 11lbs
Mounting Integral mounting plate with 4 x mounting holes suitable for M8 bolts. Optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3" (2" nominal)
Cable Entries UL\cUL versions: 2 x ¾"NPT conduit entries. Suitable blanking plug supplied for use if only 1 entry used. Seal to maintain IP rating; ATEX/IECEx versions: 2 x M20 cable entries
Environmental
IP Rating IP66 in accordance with EN60529:1992

Certification
US, Latin America, Canada UL/c-UL - Class I, Division 1, Groups B, C and D, Class I, Division 2, Groups B, C & D, Class II, Division 1, Groups E, F & G, Class II, Division 2, Groups F & G. -40°C to +65°C
European ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
International IEC Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
EMC CE: EN50270:2006 EN6100-6-4:2007
Performance UL508; CSA 22.2 No. 152 (flammable gasses, excludes infrared sensors); ATEX, IEC/EN60079-29-1:2007, EN45544, EN50104, EN50271; China: PA Pattern Measurement (for transmitter and toxic gas sensors) “CCCF” Shenyang for Flammable (fire dept approval)

Honeywell Sensepoint XCD Part Number

Honeywell Sensepoint XCD Option Matrix

Export Info
Made inSouth Korea
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    17 Items found.
SPXCDMTBR
(670)

HONEYWELL  SPXCDMTBR

Mounting bracket for Honeywell Sensepoint XCD Sensors. Includes bolts, nuts and brackets



$104.72 
S3KCAL
(667)

HONEYWELL  S3KCAL

Calibration Cap/Cup for Honeywell Sensepoint XCD Sensors.



$117.16 
(668)

HONEYWELL  SPXCDCC

Collecting cone for use with lighter than air gases for Honeywell Sensepoint XCD Sensors.



$119.23 
CYL-90090227
(1313)

PORTAGAS  CYL-90090227

Calibration Gas Methane (CH4) 50% LEL 2.5% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90302139
(1259)

PORTAGAS  CYL-90302139

Calibration Gas Butane (C4H10) 50% LEL (0.9%) Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-10624200
(1305)

PORTAGAS  CYL-10624200

Calibration Gas Propane (C3H8) 50% LEL 1.06%Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90095187
(6713)

PORTAGAS  CYL-90095187

Calibration Gas Propane (C3H8) 50% LEL 1.1%Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-10305400
(3238)

PORTAGAS  CYL-10305400

Calibration Gas Hexane 40% LEL (4400 ppm) Balance Air Size 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder (Made by Portagas)

Configure

$124.51 
CYL-10241000
(4296)

PORTAGAS  CYL-10241000

Calibration Gas Ethane (C2H6) 50% LEL 1.5% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90301910
(933)

PORTAGAS  CYL-90301910

Calibration Gas Hydrogen (H2), 50% LEL 2% vol Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90095251
(2040)

PORTAGAS  CYL-90095251

Calibration Gas Methane (CH4) 60% LEL 3% vol. Balance Nitrogen, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90095224
(2926)

PORTAGAS  CYL-90095224

Calibration Gas Methane (CH4) 60% LEL 3% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90411390
(2927)

PORTAGAS  CYL-90411390

Calibration Gas Hydrogen (H2) 60% LEL 2.4% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
SPXCDSDP
(671)

HONEYWELL  SPXCDSDP

Sunshade/Deluge Protection for Honeywell Sensepoint XCD Sensors.



$402.28 
SPXCDDMK
(669)

HONEYWELL  SPXCDDMK

Duct mounting kit for Honeywell Sensepoint XCD Sensors.



$443.75 
SPXCDXSFXSS
(675)

HONEYWELL  SPXCDXSFXSS

Replacement Sensor Cartridge for Flammable CAT (Catalytic) XCD Detector 0-100%LEL (20.0 to 100.0%LEL)



$540.17 
TPPLBDWA2NNNNNN
(5825)

HONEYWELL  TPPLBDWA2NNNNNN

Honeywell Touchpoint Plus Wall-mounted Alarm Controller for up to 8 gas detection channels (16 w/ expansion unit). Dustproof and waterproof. Polycarbonate ABS Housing (NEMA 4X). Includes touchscreen interface, built-in sounder, 3 alarm relay outputs, datalogging to SD card and remote reset and inhibit inputs. AC or DC supply voltage. Up to 24 relay outputs and 8mA outputs. IP65. UL and CSA approvals (Class I Div 2).

> LEL CATALYTIC BEAD :    27 Items found.
GD-2B
(2047)

MACURCO  GD-2B

Macurco GD-2B Gas Detector for combustibles (heating type gases). Low voltage and designed for connection to Fire Alarm/Burglary Control Panels. 9-32 VDC or 12-24 VAC input. Meets UL 2075 standard. Alarm, trouble relays and 85dB buzzer.



$117.91 
GD-2A
(650)

MACURCO  GD-2A

MACURCO Combustible Gas Detector low voltage all-electronic monitor engineered to detect heating type gases, including methane (natural gas) and propane(bottled gas). 12-24 VAC or VDC input. SPDT alarm and NC trouble relays. Listed to UL Standard 2075. CSFM Approved.



$117.91 
PC3-3012
(6801)

PROSENSE  PC3-3012

Prosense PC3-XY12 Gas Detector with Catalytic Bead sensor for Hydrocarbons (LPG, Methane, n-Butane, Propane, Hydrogen or Pentane) with range 0-100% LEL. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$231.66 
P-3012PE
(6799)

PROSENSE  P-3012PE

Prosense P-XY12PE Gas Detector with Catalytic Bead sensor for Hydrocarbons (LPG, Methane, Petrol Vapour, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20mA Analog output. Optional Relay Outputs. ATEX/IECEx approval. IP65.

Configure

$308.88 
P-3012PEK
(6800)

PROSENSE  P-3012PEK

Prosense P-XY12PEK Gas Detector with Catalytic Bead and Motion sensor for Hydrocarbons (LPG, Methane, Petrol Vapour, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. ATEX/IECEx approval. IP65.

Configure

$308.88 
P-3035
(6721)

PROSENSE  P-3035

Prosense P-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$437.58 
P-5535
(6774)

PROSENSE  P-5535

Prosense P-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$437.58 
GD-6
(1234)

MACURCO  GD-6

MACURCO GD-6 low voltage Gas Detector, Controller and Transducer for Combustibles 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1, CSA Approved.

Configure

$481.90 
SPSTAXF1
(1475)

HONEYWELL  SPSTAXF1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Methane (CH4) 0-100% LEL (combustibles) complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 3 wire bridge output. ATEX Approved. Poison resistant catalytic bead.

Configure

$482.11 
GD-12
(3416)

MACURCO  GD-12

MACURCO GD-12 line voltage Gas Detector, controller and transducer for Combustibles (EX) 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1, CSA Approved.

Configure

$494.01 
2106B1200
(1469)

HONEYWELL  2106B1200

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. ATEX/IECEx Certified.

Configure

$575.52 
PQN-3035-1/2
(6947)

PROSENSE  PQN-3035-1/2

Prosense PQN-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$617.76 
PQN-5535-1/2
(6950)

PROSENSE  PQN-5535-1/2

Prosense PQN-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$617.76 
PQD-3035-1/2
(6718)

PROSENSE  PQD-3035-1/2

Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$772.20 
PQD-5535-1/2
(6736)

PROSENSE  PQD-5535-1/2

Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$772.20 
2106B2310
(1640)

HONEYWELL  2106B2310

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. High Temperature (150°C with 3rd party performance approval) ATEX

Configure

$855.75 
OI-6000-CB2-LEL-X-X-O
(6836)

OTIS  OI-6000-CB2-LEL-X-X-O

Otis Instruments OI-6000 Gas Leak Detector with catalytic bead sensor for Combustibles 0-100 % LEL. Explosion Proof Wired power (3-Wire). (12 to 35 VDC) with 4-20 mA analog and RS-485 Modbus outputs. 3 Push-Button Interface. IP 66/67. Optional alarm relays and Radio. CSA Approved for Class I Div 1. ATEX Zone 1 and IECEx Certified.

GG-LEL2-CH4
(4137)

CALIBRATION TECHNOLOGIES  GG-LEL2-CH4

CTI GG-LEL2 Combustible Catalytic Bead Gas Detector Transmitter (0-100% LEL) for Methane (CH4), Hydrogen (H2), Propane (C3H8), N-Butane (C4H10), Ethane (C2H6), Ethylene (C2H4), N-hexane (C6H14) or N-pentane (C5H12). 4-20 mA output, 24VDC power supply. Explosion proof Copper-free aluminum enclosure for Class l, Div 1, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved. Optional Relay output.

Configure

$1,110.65 
1200ALD-109070/100P-L0
(6903)

RC SYSTEMS  1200ALD-109070/100P-L0

RC Systems SenSmart 1200 gas detector for Hydrocarbons and Hydrogen, Catalytic Bead sensor (acetylene, ammonia, butane, ethane, ethanol, hexane, hydrogen, isopropyl alcohol, methane, pentane, propane, propene or propylene) 0-100% LEL with 'ST-48' smart transmitter. 3-Wire Bridge Output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,218.18 
965-525420-100
(5006)

DETCON  965-525420-100

Detcon MicroSafe FP-524D Smart gas detection Sensor designed to detect and monitor combustible gases with range 0-100% LEL using matched-pair catalytic bead sensor technology. Aluminum Junction Box. 4-20mA output. LED Display. Explosion Proof. IP66. CSA and ISA Approved for Class I, Division 1, Groups B, C, & D.

52001AL-0-9070/100P/L0
(7121)

RC SYSTEMS  52001AL-0-9070/100P/L0

RC Systems SenSmart 5200 3-wire gas detector with Catalytic Bead sensor for Hydrocarbons and Hydrogen (ammonia, butane, ethane, ethanol, hexane, hydrogen, Isopropyl alcohol, pentane, propane, propene, propylene) 0-100% LEL with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
XNXUTAVNNCB1
(852)

HONEYWELL  XNXUTAVNNCB1

Honeywell XNX Universal Gas Detector Transmitter including MPD CATALYTIC BEAD sensor combustible 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas). Backlit LCD Display, HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2, INMETRO

Configure

$1,728.46 
XCDRFDL
(3004)

HONEYWELL  XCDRFDL

Honeywell Sensepoint XCD RFD (Remote Flammable Detector) Kit. Includes transmitter with LM25, 3/4“NPT Entry, 705 sensor, and 3 wire junction box. Tri-colour backit display. Outputs include 2 programmable alarm relays, 1 programmable fault relay, 4-20mAoutput (sink or source selectable). Sensor can be mounted up to 30 metres (100 feet) from transmitter. cCSAus Certified for North America. Class 1, Div 1, Groups B, C, & D.

Configure

$1,734.98 
967-521520-100
(5005)

DETCON  967-521520-100

Detcon FP-700 non-intrusive Smart Sensor designed to detect and monitor combustible gases with range 0-100% LEL using catalytic bead sensor technology. Aluminum or Stainless Steel Junction Box. 4-20mA and Modbus RS-485 outputs. LED Display. Explosion Proof. IP66. CSA, ATEX, CE and SIL2 Approved.

966-524520-100
(6100)

DETCON  966-524520-100

Detcon FP-624D Combustible 0-100% LEL Smart Sensor with catalytic bead. Includes detector in stainless steel housing, base connector board, explosion proof enclosure, splashguard, 4-20 mA output, RS-485 serial communication and 3 alarm relays. IP66. CSA approval for Class I, Division 1, Groups C & D.

32001AL-0-9071/100P/L0
(6894)

RC SYSTEMS  32001AL-0-9071/100P/L0

RC Systems SenSmart 3200 3 wire gas detector with Catalytic Bead sensor for Hydrocarbons and Hydrogen (ammonia, butane, ethane, ethanol, hexane, hydrogen, Isopropyl alcohol, pentane, propane, propene, propylene) 0-100% LEL with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
6200AL1-0-109070/100P
(7019)

RC SYSTEMS  6200AL1-0-109070/100P

RC Systems SenSmart 6200 3 wire Dual Channel Gas Detector for Hydrocarbons and Hydrogen Catalytic Bead sensor (acetylene, ammonia, butane, ethane, ethanol, hexane, hydrogen, isopropyl alcohol, methane, pentane, propane, propene or propylene) 0-100% LEL with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
Cookie Notice