Prosense Pqd-5535-1/2 | Lel Catalytic Bead | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

PROSENSE   PQD-5535-1/2

SKU# (6736)



PROSENSE PQD-5535-1/2
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

DISPLAY   4-20 mA   RELAYS   UL   ATEX   IECEX   CSA   UL   DIV 1   ZONE 1   ZONE 2   SIL2   HART   MODBUS

PQD-5535-1/2   
772.20

Cable Entries
Gas
Relays
IP66 Adaptor
No calibration port
Stainless Series Enclosure
SIL2
HART
Certification
Remote Sensor

 3 Weeks  ]
39 Variants of base SKU / 30 Shown below
OLED Display

PROSENSE "PQD" Series fixed gas detectors are certified with ATEX/IECEx and SIL2.

Ex-proof Safety

The continuous measurement of toxic and explosive gases is done safely in hazardous areas thanks to the ex-proof housing.

Performance Approval

It complies with the measurement performance criteria in accordance with the IEC EN 60079-29-1 standard.

Functional Safety

Prosense promotes SIL approved products to reduce safety risks associated with increasingly complicated systems as malfunctioning equipment could pose a potential risk. PQ series has ongoing process for SIL-2.

Robust and Durable

SS316 stainless steel sensor head performs perfectly under harsh environmental conditions with the IP65/ IP66 protection class.

Accurate Readings

Pellistor, Electrochemical, PID, and Infrared sensors undoubtedly provide an accurate and sensitive measurement.

Ready to Operate

4-20mA Analog and Modbus RS485 RTU outputs are provided onboard to operate properly without any additional setup.

Easy Maintenance

PQD Series detectors allow sensor replacement with pre-calibrated sensor head thanks to the Procell technology.

OLED Display

The OLED screen can be easily read from any angle.

SAFELOG Data Logger

PQD Series records status up to 250 events. In case of sudden power cut, you can save the data thanks to the cell battery.

Automatic Calibration

Detector calibration can be done automatically via preset values recorded in detector software once calibration requirements are provided.

Pellistor-Saver Mode

Detectors power off the sensor in high gas concentration in order to properly secure the operational lifetime of pellistor sensor.

Auto Analog Signal Calibration and Monitoring

PQD Series detectors continuously check the analog output signal level to match the measurement level before promptly transferred to the panel. PQD Series adjusts the signal level in case of any deviation and generates a fault signal when the adjustment fails.

Zero Suppression

Adjusting, the detector can show a certain measurement level as 0 (zero) to avoid unnecessary concerns.

Simple External Equipment Control

Optional relay module enables you to use it as an independent gas detection system with two arbitrarily adjustable concentration alarms and one fault alarm.

Continuous Self-Test

The detectors check itself continuously to make sure it operates perfectly and indicates a fault in case of any failure.

Adjustable Parameters

All parameters can be easily changed according to the application requirements or facility standards.

Remote Display

Depending on the application requirements, the screen can be placed separately.

Easy Status Recognition

Colored LEDs (green, yellow and red) provide additional alarm and status information.

Maintenance via Software

Prosense provides software to maintain your active system easily and calibrate the gas detectors properly via computer.

Applications
  • Oil&Gas
  • Petrochemical
  • Onshore/Offshore
  • Steel-Metal Industry
  • Chemical Industry
  • Process Industry
  • Gas Distribution Stations
  • Water Treatment Plants

Specifications PQD-XY35
Sensor Technology Pellistor
Output Signal 4-20mA and Modbus RS485
Sensor Warm-Up 60sec
Response Time(T90) <25sec
Accuracy %1
Operating Temperature -40°C ~ +70°C
Humidity 0~ 100%RH Non-Condensing
Input Min 10VDC - Max 32VDC - Nominal 24VDC
Display 128x64 Graphic OLED
5 LED indicator for detector status
Event Logging Records alarm, fault and maintenance events up to 250 logs
Power Consumption Max. 4W
Relay Outputs 2 Alarms (Programmable) and 1 Fault (All relays are NO/NC adjustable)
Cable Entry 3x 1/2''NPT or 3x 3/4''NPT or 3x 3xM20
IP Rating IP65/IP66
Junction Box Epoxy Painted Die-Cast Aluminum / 316 Stainless Steel
Sensor Head 316L Stainless Steel
Dimensions/Weight 196,96x145,99x112mm / 2100gr
ATEX Marking II 2G Ex db IIC T6 Gb
II 2G Ex mb db IIC T6 Gb
I M2 Ex db I Mb
Hazardous Class ATEX/IECEx Zone 1 - Zone 2 - M2
UL/CSA Class I Division 1 Group A, B, C& D
Certificates ExVeritas 18 ATEX 0371X
IECEx EXV 18.0021X
FTZU 18 ATEX 0086
IEP12 ATEX 6118X
UL E521536
Optional SIL2
Standards IEC EN 60079-0
IEC EN 60079-1
IEC EN 60079-18
IEC EN 60079-29-1
Warranty 12 months from date of shipment from Prosense Technology
Export Info
Made inTurkey
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    17 Items found.
PR-KT12
(6978)

PROSENSE  PR-KT12

Prosense 1/2" NPT ATEX Certified Blind Plug for P, PQ and B Series gas detectors



$12.28 
PR-NYY12
(6976)

PROSENSE  PR-NYY12

Prosense 1/2"NPT ATEX Certified Cable Gland for P, PQ and B Series gas detectors



$18.41 
P-GTA
(7212)

PROSENSE  P-GTA

Prosense Celling Mount Collecting Cone for P and PQ gas detectors, Diameter 50cm, Hight 20cm, Material Steel plate optional stainless steel.

Configure

$92.07 
PK-K30T
(6768)

PROSENSE  PK-K30T

Prosense Teflon Calibration cup/cap for P, PE, PQ and B Series gas detectors, tubing entry 4mm diameter tubing. Optional SS316

Configure

$100.98 
10437000
(1297)

PORTAGAS  10437000

Calibration Gas Methane (CH4) 30% LEL 1.5 % vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$124.51 
90095187
(6713)

PORTAGAS  90095187

Calibration Gas Propane (C3H8) 50% LEL 1.1% Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$124.51 
90301910
(933)

PORTAGAS  90301910

Calibration Gas Hydrogen (H2), 50% LEL 2% vol Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$124.51 
PROX-EDU
(7017)

PROSENSE  PROX-EDU

Prosense PDM Software 1-Year license for maintenance, setup, calibration, monitoring and troubleshooting of PQ, P, PC3 series gas detectors. Calibration function is licensed separately, to print calibration reports or certificates directly from the program after calibration.

Configure

$165.00 
P-DM-00
(7213)

PROSENSE  P-DM-00

Prosense Duct Mount/Pipe Mount adapter for P and PQ gas detectors, made of Delrin and stainless steel

SP-PQ-DT
(7036)

PROSENSE  SP-PQ-DT

Prosense OLED Display Assembly for PQD series gas detectors



$330.00 
P-ASU-2
(6989)

PROSENSE  P-ASU-2

Prosense flow adapter cell for SH30 and SH20 sensor heads used in PQ, P, PE and PC3 series, gas sampling applications. For 6mm OD Tubing made of corrosion-resistant Teflon.



$405.90 
S-DP4
(6764)

PROSENSE  S-DP4

Prosense S-DP4 Gas Detector Controller, Alarm Panel for Up to 4 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

$772.20 
SP-PQ-TB05
(7031)

PROSENSE  SP-PQ-TB05

Prosense PQ Transmitter/Main Board for PQD and PQN series gas detectors



$825.00 
PQ-PD05A
(7056)

PROSENSE  PQ-PD05A

Prosense Handheld Terminal for maintenance, diagnostics, alarm setting, configuration, test and calibration of Prosense PQN, PQD, P and PC3 series gas detectors, uses RS-485 Modbus to connect to the detectors.



$880.00 
S-DP8
(6765)

PROSENSE  S-DP8

Prosense S-DP8 Gas Detector Controller, Alarm Panel for Up to 8 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

$900.90 
S-DPX064
(7034)

PROSENSE  S-DPX064

Prosense S-DPX064 Gas Detector Controller, Alarm Panel for 64 x RS485 MODBUS RTU Detectors + 8 x 4-20 mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

$1,801.80 
S-DPX128
(7035)

PROSENSE  S-DPX128

Prosense S-DPX128 Gas Detector Controller, Alarm Panel for 128 x RS485 MODBUS RTU Detectors + 8 x 4-20 mA Analogue Channels, OLED Display, Alarm and Fault LED indicators for each detector and buzzer. Includes Modbus RTU RS485 output, 5 common alarm relays: Fault, Alarm-1, Alarm-2, Alarm-3 and overrange. Polycarbonate Housing, IP66.

Configure

$2,316.60 
> LEL CATALYTIC BEAD :    27 Items found.
GD-2A
(650)

MACURCO  GD-2A

MACURCO Combustible Gas Detector low voltage all-electronic monitor engineered to detect heating type gases, including methane (natural gas) and propane(bottled gas). 12-24 VAC or VDC input. SPDT alarm and NC trouble relays. Listed to UL Standard 2075. CSFM Approved.



$117.91 
GD-2B
(2047)

MACURCO  GD-2B

Macurco GD-2B Gas Detector for combustibles (heating type gases). Low voltage and designed for connection to Fire Alarm/Burglary Control Panels. 9-32 VDC or 12-24 VAC input. Meets UL 2075 standard. Alarm, trouble relays and 85dB buzzer.



$117.91 
PC3-3012
(6801)

PROSENSE  PC3-3012

Prosense PC3-XY12 Gas Detector with Catalytic Bead sensor for Hydrocarbons (LPG, Methane, n-Butane, Propane, Hydrogen or Pentane) with range 0-100% LEL. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$231.66 
P-3012PEK
(6800)

PROSENSE  P-3012PEK

Prosense P-XY12PEK Gas Detector with Catalytic Bead and Motion sensor for Hydrocarbons (LPG, Methane, Petrol Vapour, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. ATEX/IECEx approval. IP65.

Configure

$308.88 
P-3012PE
(6799)

PROSENSE  P-3012PE

Prosense P-XY12PE Gas Detector with Catalytic Bead sensor for Hydrocarbons (LPG, Methane, Petrol Vapour, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20 mA Analog output. Optional Relay Outputs. ATEX/IECEx approval. IP65.

Configure

$308.88 
P-5535
(6774)

PROSENSE  P-5535

Prosense P-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$437.58 
P-3035
(6721)

PROSENSE  P-3035

Prosense P-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$437.58 
GD-6
(1234)

MACURCO  GD-6

MACURCO GD-6 low voltage Gas Detector, Controller and Transducer for Combustibles 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1, CSA Approved.

Configure

$481.90 
GD-12
(3416)

MACURCO  GD-12

MACURCO GD-12 line voltage Gas Detector, controller and transducer for Combustibles (EX) 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1, CSA Approved.

Configure

$494.01 
SPSTAXF1
(1475)

HONEYWELL  SPSTAXF1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Methane (CH4) 0-100% LEL (combustibles) complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 3 wire bridge output. ATEX Approved. Poison resistant catalytic bead.

Configure

$506.22 
2106B1200
(1469)

HONEYWELL  2106B1200

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. ATEX/IECEx Certified.

Configure

$604.30 
PQN-3035-1/2
(6947)

PROSENSE  PQN-3035-1/2

Prosense PQN-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$617.76 
PQN-5535-1/2
(6950)

PROSENSE  PQN-5535-1/2

Prosense PQN-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$617.76 
PQD-3035-1/2
(6718)

PROSENSE  PQD-3035-1/2

Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$772.20 
2106B2310
(1640)

HONEYWELL  2106B2310

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. High Temperature (150°C with 3rd party performance approval) ATEX

Configure

$898.54 
GG-LEL2-CH4
(4137)

CALIBRATION TECHNOLOGIES  GG-LEL2-CH4

CTI GG-LEL2 Combustible Catalytic Bead Gas Detector Transmitter (0-100% LEL) for Methane (CH4), Hydrogen (H2), Propane (C3H8), N-Butane (C4H10), Ethane (C2H6), Ethylene (C2H4), N-hexane (C6H14) or N-pentane (C5H12). 4-20 mA output, 24VDC power supply. Explosion proof Copper-free aluminum enclosure for Class l, Div 1, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved. Optional Relay output.

Configure

$1,110.65 
1200ALD-109070/100P-L0
(6903)

RC SYSTEMS  1200ALD-109070/100P-L0

RC Systems SenSmart 1200 gas detector for Hydrocarbons and Hydrogen, Catalytic Bead sensor (acetylene, ammonia, butane, ethane, ethanol, hexane, hydrogen, isopropyl alcohol, methane, pentane, propane, propene or propylene) 0-100% LEL with 'ST-48' smart transmitter. 3-Wire Bridge Output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,218.18 
965-525420-100
(5006)

DETCON  965-525420-100

Detcon MicroSafe FP-524D Smart gas detection Sensor designed to detect and monitor combustible gases with range 0-100% LEL using matched-pair catalytic bead sensor technology. Aluminum Junction Box. 4-20 mA output. LED Display. Explosion Proof. IP66. CSA and ISA Approved for Class I, Div 1, Groups B, C, & D. Optional HART.

SPXCDULNFX
(658)

HONEYWELL  SPXCDULNFX

Honeywell XCD Sensepoint Gas Detector, CATALYTIC BEAD combustible 0-100% LEL (Lower Explosive Limit) Methane CH4 (LNG-natural gas), Propane C3H8 (LPG), Butane C4H10, Pentane, Hexane, Ethanol, Hydrogen with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20 mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%, can be calibrated to several other combustible gases. UL/CSA Class I Div 1 or ATEX (Zone 1) IECEx available.

Configure

$1,442.65 
52001AL-0-9070/100P/L0
(7121)

RC SYSTEMS  52001AL-0-9070/100P/L0

RC Systems SenSmart 5200 3-wire gas detector with Catalytic Bead sensor for Hydrocarbons and Hydrogen (ammonia, butane, ethane, ethanol, hexane, hydrogen, Isopropyl alcohol, pentane, propane, propene, propylene) 0-100% LEL with GEN2 smart sensor, Color backlit LCD Display and 4-20 mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Div 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays, HART.

Configure

$1,594.80 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.