Detcon 961-340026-025g | Oxygen | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

DETCON   961-340026-025G

DETCON 961-340026-025G
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Detcon DM-100-O2 Electrochemical Oxygen (O2) 0-25%vol Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

961-340026-025G   
Please Email us your request for quote   

Terminal Material
Approval
Alarm Relay Module

   3 Weeks  ]
9 Variants of base SKU

Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a 3⁄4 inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.

Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel (includes a transient protection terminal board). Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.

Features
  • XP-intrinsically Safe
  • Class I, Div. 1, Groups B, C & D
  • 2 Wire Loop powered
  • Field Replaceable Electrochemical Sensor
  • Non-intrusive Magnetic Interface
  • Built-in Diagnostics
  • Fully Encapsulated ITM Electronics
  • Electropolished 316SS Construction ITM
  • Quick Thread Release (for sensor replacement)
  • Integral Calibration Port
Applications
  • Oil and Gas
  • Chemical Plants
  • Food and Beverage
  • Steel Mills
  • Pulp and Paper
  • Refineries
  • Waste Water Treatment Plants
  • Utilities

System Specifications
Sensor TypeContinuous diffusion/adsorption
2-electrode electrochemical cell
Plug-in field replaceable Type
Span Drift<5% signal loss per year (in first 2 years)
OutputsLinear 4-20 mA DC
Electrical ClassificationExplosion proof
cCSAus
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C)
Measurement Range0-100 ppm, Other ranges available
Safety ApprovalsCCSAUS
Sensor Life/WarrantyPlug-in cell - 2 years (2 years expected life) ; Transmitter - 2 Years
Environmental Specifications
Operating Temperature Range-4 to 122oF/-20 to 50oC
Storage Temperature Range-40 to 122oF/ -40 to 50oC
Operating Humidity Range0% to 99% RH non-condensing (continuous)
0%-100% RH (intermittent)
Operating Pressure RangeAtmospheric ±10%
Mechanical Specifications
Dimensions7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box)
Mounting holes (J-box) 5.5" (140mm) center to center
Weight2 lbs; 0.907 kg (sensor only)
6 lbs; 2.72 kg (w/aluminum j-box)
9 lbs; 4.08 kg (w/stainless steel j-box)
Electrical Specifications
Power Input11 - 30 VDC
Power ConsumptionNormal operation = 30mA @ 24V (<0.75 watt)
Maximum = 50mA @ 24V (1.2 watts)
Inrush Current500mA @ 24V (typical)
Analog OutputLinear 4-20mA DC (1,000 ohms max loop load @ 24VDC)< br/> 0mA: All Fault Diagnostics
2mA: In-Calibration
4-20mA: 0-100% full-scale
22mA: Over-range condition
Status IndicatorsOptional 4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting
Faults MonitoredLoop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration
Cable RequirementsPower/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
Maximum distance is 4,000 feet to last sensor
I/O ProtectionOver-voltage, Miswiring
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
943-000000-000
(6566)

DETCON  943-000000-000

Detcon Calibration Sleeve/Wind Guard for use with sensor splash guard for all Detcon sensor heads.



 
> OXYGEN :    29 Items found.
BWC2-X
(4267)

BW  BWC2-X

BW Clip portable gas detector 2 year maintenance free for Oxygen O2. Low alarm set at 19.5%, High alarm set 23.5%. UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.



 
M001-0032-000
(6005)

MPOWER  M001-0032-000

mPower UNI MP100 Portable Single Gas Detector for detection of Oxygen (O2) 0-25% or 0-30% vol. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$150.40 
BWC2R-X
(5151)

BW  BWC2R-X

BW Clip Real Time portable gas detector with 2 year maintenance free for Oxygen (O2). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

BWS1-XL-Y
(6392)

BW  BWS1-XL-Y

BW Solo Serviceable Single-gas Detector for Oxygen (O2) 0-30% v/v. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PC3-6524
(6806)

PROSENSE  PC3-6524

Prosense PC3-6524 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25% vol. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$463.32 
OX-6
(4089)

MACURCO  OX-6

MACURCO OX-6 low voltage Gas Detector, Controller and Transducer for Oxygen (O2) 0-25% vol. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$481.90 
OX-12
(4090)

MACURCO  OX-12

MACURCO OX-12 line voltage Gas Detector, controller and transducer for Oxygen (O2) 0-25% vol. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$494.01 
P-6534
(6781)

PROSENSE  P-6534

Prosense P-6534 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25% vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$540.54 
SPSTAXO2
(1476)

HONEYWELL  SPSTAXO2

Honeywell Zareba Sensepoint Gas Detector Transmitter for Oxygen (O2) 0-25% VOL complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. *** Replaces SPSTAXO1 ***

Configure

$648.84 
364-455-01-365-251-11
(6157)

DELPHIAN  364-455-01-365-251-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Oxygen (O2) 0-21% vol. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PQN-6534-1/2
(6954)

PROSENSE  PQN-6534-1/2

Prosense PQN-6534 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25%. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$720.72 
XT-X000-Y-NA
(578)

BW  XT-X000-Y-NA

GasAlertMax XT 4-Gas Detector for O2 (Oxygen). Monitors up to 4 gas hazards for confined space entry and remote sampling.

PQD-6534-1/2
(6742)

PROSENSE  PQD-6534-1/2

Prosense PQD-6534 Gas Detector with Electrochemical sensor for Oxygen (O2) with range 0-25%. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$875.16 
GG-O2-C0
(2968)

CALIBRATION TECHNOLOGIES  GG-O2-C0

CTI GasGuard O2 Oxygen Electrochemical Sensor (15-25% or 0-25%) for gas leak detection in food air quality monitoring, refrigeration systems, confined space and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,122.00 
2106B1430
(1468)

HONEYWELL  2106B1430

Honeywell Sieger Sensepoint Gas Detector Transmitter for Oxygen (O2) 25% V/V with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
1100ALD-109010/30P-L0
(6916)

RC SYSTEMS  1100ALD-109010/30P-L0

RC Systems SenSmart 1100 gas detector for Oxygen (O2) 0-25% with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,314.28 
SPXCDULNO1
(662)

HONEYWELL  SPXCDULNO1

Honeywell XCD Sensepoint Gas Detector, Oxygen (O2) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for oxygen (O2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 25%Vol. only UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,379.12 
100-0008-SS/100-0015-O2
(4760)

ESP SAFETY  100-0008-SS/100-0015-O2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Oxygen (O2) 0-30% vol. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
S3KUL2-XNXXSO1SS
(682)

HONEYWELL  S3KUL2-XNXXSO1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring OXYGEN (O2) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-25%VOL Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,497.56 
41001AL-0-1026/0030P/L0
(7177)

RC SYSTEMS  41001AL-0-1026/0030P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Sulfur Dioxide (SO2) 0-10ppm to 0-500ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.