Simplex Tyco 4090-9008 Dual Contact Relay IAM (Individual Addressable Module) for up to two IDNet or MAPNET II communications.

Please Email us your request for quote   

   In Stock  ]
Features

Dual Contact Relay IAM (Individual Addressable Module):

Xenon strobe visible notification appliance:
  • A single addressable point provides control and status tracking of two, 2 A Form “C” contacts
  • Low power latching relay design allows IDNet or MAPNET II communications to supply both data and module power
  • Relay is set to OFF on initial power up and upon loss of IDNet or MAPNET II communications
For use with following Simplex control panels:
  • Model Series 4007ES, 4010ES, 4100ES, and 4100U fire alarm control panels for IDNet communications
  • Model Series 4100/4100U/4100ES, 4120, 4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications
Compact construction:
  • Mounts in standard 4” (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 11⁄16” square electrical box
  • Screw terminals for wiring connections
  • Visible LED flashes to indicate communications, can be selected at panel to indicate activated state
  • Optional 4” square box covers are available to allow LED to be viewed after installation
Description

Dual Contact Relay IAMs allow fire alarm control panels to control two remotely located Form “C” contact using IDNet or MAPNET II addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address.

Specifications
Communications IDNet or MAPNET II communications, 1 address per device
Power Supplied by communications
Installation Instructions 579-1040
IDNet Firmware Requires 3.12.04 or higher
Type Dual Form C contacts (DPDT) with terminal block access to Common, N.O., and N.C for each contact
Power-Limited 2 A @ 30 VDC, resistive
1 A @ 30 VDC, inductive
Nonpower-Limited 0.5 A @ 125 VAC, resistive
Relay Fusing Each contact common is fused with a 2 A fast acting non-time delay fuse
Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2)
IDNet or MAPNET II Communications Wiring Reference Up to 2500 ft ( 762 m) from control panel
Up to 10,000 ft ( 3048 m) total wiring distance (including T-Taps)
Compatible with Simplex 2081-9044 Overvoltage Protectors
Dimensions 4 ⅛” H x 4” W x 1 ⅜” D (105 mm x 102 mm x 35 mm)
Mounting Plate Sheet metal, galvanized
Temperature Range 32° to 120° F (0° to 49° C), intended for indoor operation
Humidity Range Up to 93% RH at 100° F (38° C)
Export Info
Made inMexico
Harmonized Tariff Code (HTC)85311001

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> SIMPLEX TYCO :    50 Items found.
4905-9931
(7274)

SIMPLEX TYCO  4905-9931

Simplex Tyco 4905-9931 Adapter Plate, Red, for mounting to Simplex 2975-9145 Box



 
517.050.041
(7487)

SIMPLEX TYCO  517.050.041

Simplex Tyco 517.050.041 4B Universal Base for 800, 814, and 850 Series detectors. 20 to 40Vdc.



 
4090-5201
(7484)

SIMPLEX TYCO  4090-5201

Simplex 4090-5201 Mini-IAMs (Individual Addressable Module) for remote monitoring of a single input.



 
4905-9909
(7532)

SIMPLEX TYCO  4905-9909

Simplex Tyco 4905-9909 Audible Adaptor Plate



 
(7482)

SIMPLEX TYCO  734-015

Simplex Tyco 734-015 4100U/ES Battery Harness



 
4905-9996
(7474)

SIMPLEX TYCO  4905-9996

Simplex Tyco 4905-9996 Red wall mount S/V replacement cover with white FIRE lettering.



 
4090-9001
(7445)

SIMPLEX TYCO  4090-9001

Simplex Tyco 4090-9001 Supervised Individual Addressable Module (IAMs). IDNet and MAPNET II. Thermoplastic housing. UL, ULC, CSFM Listed. FM Approved.



 
4905-9937
(7277)

SIMPLEX TYCO  4905-9937

Simplex Tyco 4905-9937 Adapter Skirt for 4902-921X TrueAlert electronic chimes



 
4098-9866
(7490)

SIMPLEX TYCO  4098-9866

Simplex Tyco 4098-9866 Rotation Adapter 520Hz Base



 
4081-9004
(7275)

SIMPLEX TYCO  4081-9004

Simplex Tyco 4081-9004 End-of-Line Resistor Harness, 6.8K, 1/2 W. UL Listed.



 
2099-9822
(7483)

SIMPLEX TYCO  2099-9822

Simplex Tyco 2099-9822 Replacement retaining clip for breakglass



 
4098-9832
(7273)

SIMPLEX TYCO  4098-9832

Simplex Tyco 4098-9832 Adapter Plate, 6-3/8” (162 mm) diameter, 1/4” (6.4 mm) deep, matches bases, required for some mounting combinations.



 
4090-9116
(7272)

SIMPLEX TYCO  4090-9116

Simplex Tyco 4090-9116 Addressable IDNet Communications Isolator. UL, ULC, CSFM Listed. FM Approved.



 
2098-9806
(7271)

SIMPLEX TYCO  2098-9806

Simplex Tyco 2098-9806 Remote Test Station Mounted on a Single Gang Stainless Steel Plate



 
4098-9789
(7270)

SIMPLEX TYCO  4098-9789

Simplex Tyco 4098-9789 Sensor Base with connections for Remote LED Alarm Indicator or Unsupervised Relay



 
49SVC-CWALT
(7269)

SIMPLEX TYCO  49SVC-CWALT

Simplex Tyco 49SVC-C S/V covers for 49SV-APPLC speakers.

2975-9178
(7268)

SIMPLEX TYCO  2975-9178

Simplex Tyco 2975-9178 Surface Mount Steel Box, Red



 
565-454
(7267)

SIMPLEX TYCO  565-454

Simplex Tyco 4098-9754 Card 2Z Signal Class A PCA 4109



 
4090-9810
(7266)

SIMPLEX TYCO  4090-9810

Simplex Tyco 4090-9810 Mounting Bracket for IAM (required for optional trim plates)



 
2975-9145
(7276)

SIMPLEX TYCO  2975-9145

Simplex Tyco 2975-9145 Red Mounting Box; requires Adapter Plate 4905-9931



 