Notifier Ncd | Notifier Onyx Series | Annunciators | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

NOTIFIER   NCD

SKU# (7024)
NOTIFIER NCD
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier NCD Network Control Display annunciator for NOTIFIER INSPIRETM and ONYX series fire alarm control panels. 24 VDC. USB C, USB Micro, and USB A. Trouble Relay.

Please Email us your request for quote   

   4 Weeks  ]

The Network Control Display (NCD) is the next generation of network control annunciators for the NOTI•FIRE•NETTM network. Its contemporary design meets today’s building aesthetics. The intuitive 1024 x 600 10" touch screen provides detailed color coded system status and point information. It is compatible with NOTIFIER INSPIRETM and ONYX® series fire alarm control panels (FACP) and nodes such as the INSPIRE N16e/x FACPs, ACM-30 annunciator and RLD remote display as well as the ONYX NFS2-3030, NFS2-640, and NFS-320 FACPs.

The NCD provides system control and status/history display capabilities for all, or for selected network nodes. It can also be used as the primary display for control and status capabilities on a displayless node via Direct Connect.

Hardware Features
  • Full supervision of all inputs and network integrity.
  • High definition 10" 1024 x 600 color touchscreen display.
  • LED status indicators for power and off normal
  • Requires 24 VDC, and a network connection or direct connect.
  • Three USB 2.0 connections, USB C, USB Micro, and USB A.
  • Trouble Relay.
  • Tamper and Trouble inputs.
Function Features
  • Device information, including point address and description, can be quickly identified.
  • Network-wide: Acknowledge, Silence, Reset.
  • Lamp Test.
  • Interactive Summary Event Count display and event handling.
  • Intuitive user guidance program.
  • Fully programmable node-mapping subsystem.
  • Up to 2000 programmable logic zones
  • Up to 32 custom action buttons
  • Environmental adjustment controls to maximize display legibility.
  • Color coded Icon based event notification.
  • Can be used as FACP primary display.
  • Supports standard and high speed network systems.
  • Event vectoring for quick viewing of event groups.
  • Virtual alphanumeric QWERTY keypad and numeric keypad displays when data input is needed.
  • Individual Enable/Disable or group Enable/Disable for networked ONYX and INSPIRE series panels.
  • Control ON/OFF for networked ONYX and INSPIRE series panel control points.
  • Read Status networked ONYX and INSPIRE series panel points and zones.
  • History Buffer (10,000 events, 3000 displayed).
  • Up to 50 unique users and 5 different user levels.
  • Read Status from event display.
  • History filters for report displaying.
  • Timer control for Auto Silence, AC Fail Delay.
  • Custom wallpaper
NCD Indicators and Controls LED INDICATORS

Green LED illuminates when 24 VDC power is applied; When on battery backup, the green LED will not illuminate.

Yellow LED illuminates when an off normal condition exists.

VIRTUAL EVENT INDICATORS
  • FIRE ALARM (red) illuminates when at least one fire alarm event exists.
  • CO Alarm (blue) illuminates when at least one CO alarm event exists.
  • SUPERVISORY (yellow) illuminates when at least one supervisory event exists (i.e., sprinkler valve off normal, low pressure, fire pump running, guard’s tour, etc.).
  • TROUBLE (yellow) illuminates when at least one trouble event exists.
  • POINT DISABLED (yellow) illuminates when at least one disable exists on the network or in the system.
  • OTHER (varies) illuminates for SECURITY, PRE-ALARM, CO PRE-ALARM, and CRITICAL PROCESS.
  • SIGNALS SILENCED (yellow) illuminates if the NCD Silence touch point has been pressed or if any other node sent a Network Silence command.
FUNCTION TOUCHPOINTS
  • Menu
  • Login
  • Acknowledge
  • Signal Silence
  • System Reset
  • Drill

Ack (Acknowledge) Tap this touchpoint to acknowledge off all active events.
Silence (Signal Silence) Tap this touchpoint to turn off all control modules, notification appliance circuits, and panel output circuits that have been programmed as Silenceable.
Reset (System Reset) Tap this touchpoint to clear all latched alarms and other events and clear event indicators.
Drill Hold this touchpoint down for two seconds, to activate all silenceable output circuits. NOTE: When enabled, the drill touch- point will be displayed in the Alert Bar.

MENU FUNCTION TOUCHPOINTS

Menu function touchpoints are accessed with the menu dialogs.

  • ABOUT – tap this touchpoint to view current firmware and hardware revision numbers.
  • DISPLAY – tap this touchpoint to adjust display settings.
  • LAMP TEST – tap this touchpoint to test display pixels, LED indicators and piezo.
Agency Listings and Approvals

The file number(s) below reference the specific listings for the modules in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL Listed: S635.
  • FM Approved
  • CSFM: 7165-0028:0516
  • FDNY: COA#001761
Standards and Codes

These listings and approvals below apply to the NCD. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL 864, 10th edition
  • NFPA 72 National Fire Protection Association

Specifications
ELECTRICAL REQUIREMENTSThe NCD may be powered from any UL Listed non-resettable 24 VDC source from a NOTIFIER compatible fire panel (see panel data sheets).
Power source:The N16 on board power supply
PMB-AUX
The NFS2-640 and NFS-320 on-board power supply
AMPS-24 (120 VAC, 50/60 Hz) or AMPS-24E (240 VAC, 50/60 Hz) power supply
A supervised +24 VDC power supply that is UL-listed for fire protective service.
Current consumption:360 mA
Weight::3 lbs (1.36 kilograms).
Temperature and Humidity Ranges:This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (non-condensing) of 85% at 30°C (86°F) per NFPA. However, the useful life of the system’s standby batteries and the electronic components may be adversely affected by extreme tem- perature ranges and humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F).
Export Info
Made inMexico

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    4 Items found.
(7025)

NOTIFIER  DP-GDIS1

Notifier DP-GDIS1 Graphic Annunciator Dress Plate to mount the 10" graphic display and ONYX Series Annunciators in a CAB-4 Series cabinet.

NCM-F
(3507)

NOTIFIER  NCM-F

Notifier NCM-F or NCM-W network communication module for NOTIFIER Intelligent Fire Alarm Control Panels and Annunciators. Fiber optic or twisted-pair wire connection. 24 VDC.

HS-NCM-MF__
(4326)

NOTIFIER  HS-NCM-MF

Notifier HS-NCM High-Speed Network Communications Module. Single or Multi-mode versions available. Allow connection from Notifier Panels to NOTI•FIRE•NET with a fiber-optic cable or twisted-pair wire. NFPA Style 4 (Class B) or Style 7 (Class A) operation. 24 VDC, 100Mb baud transmission rate. UL, ULC, CSFM and FM approved.

NFS-320
(2039)

NOTIFIER  NFS-320

NOTIFIER by Honeywell ONYX Series NFS-320 Intelligent Addressable Fire Alarm Control Panel. Certified for seismic and marine applications. Supports up to 159 detectors and 159 modules. Standard 80-character display and 6A power supply. Built-in Alarm, Trouble, Security and Supervisory relays, FlashScan network prototol.

> NOTIFIER ONYX SERIES :    6 Items found.
NCA/640-2-KIT
(3510)

NOTIFIER  NCA/640-2-KIT

Notifier NCA/640-2 kit for ONYX Series fire control panels



 
NCA-2RETRO
(3509)

NOTIFIER  NCA-2RETRO

Notifier NCA-2RETRO kit for ONYX Series fire control panels



 
ISO-X
(3235)

NOTIFIER  ISO-X

Notifier ISO-X Fault Isolator Module for Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). Powered by SLC loop. High noise immunity. UL, FM, CSFM, MEA and BSA Approved.



 
ACM-24AT
(6867)

NOTIFIER  ACM-24AT

Notifier ACM-24AT Annunciator for control of up to 24 NOTIFIER ONYX Series Intelligent Fire Alarm Control Panels, Network Control Annunciators or Addressable Panels. 24 VDC. Includes 24 yellow Trouble LEDs, 24 momentary touch-pad switches, a System Trouble LED, an On-Line/Power LED, and a local piezo sounder.



 
NCA-2
(3508)

NOTIFIER  NCA-2

Notifier NCA-2 for ONYX Series fire control panels



 
CPU2-640
(6868)

NOTIFIER  CPU2-640

Notifier CPU2-640 Central processing unit with integral 3.0 A (6.0 A in alarm) power supply for an NFS2-640 system. Includes control panel factory-mounted on a chassis, one Signaling Line Circuit (expandable to two) and documentation kit.

Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.