Esp Safety 100-0008-ss/100-0015-cl2 | Chlorine | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

ESP SAFETY   100-0008-SS/100-0015-Cl2

ESP SAFETY 100-0008-SS/100-0015-Cl2
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Chlorine (Cl2) 0-10ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

100-0008-SS/100-0015-Cl2   
1,440.00

Enclosure Type
Optional Sensor

 6 Weeks  ]



ESP Safety’s Vector is a state-of the-art field control unit that performs as an integrated control terminal and display for ESP Safety’s gas detector product line.

The Vector can operate as a stand-alone display for a variety of ESP Safety’s detectors which can be remotely located up to 500 feet away. A sensor head can also be attached directly to the display housing to produce a unified detector/display unit.

Key Features
  • A vivid, 2.7” (diagonal) 128x64 pixel resolution, OLED screen simultaneously displays a wide range of data including gas concentrations, alarm levels, faults and operational modes.
  • Analog 4-20 current loop w/ HART , Digital RS-485 Modbus RTU and 4 relays are standard data communication channels of the VECTOR FCU
  • Event log is stored in on-board memory and is accessible via RS-485 Modbus RTU
  • Operating Temp Range of -58°F to +167°F (-50°C to +75°C)
  • Configurable to control & monitor up to 2 detectors
  • SIL certification by independent 3rd party agency
  • 316 Stainless Steel construction, explosion-proof housing, Class 1, Division 1
  • Non-Instrusive, on-site detector calibration via a HART Field Communicator or Magnectic Wand
Applications
  • Offshore platforms
  • Land rigs
  • Shipping tankers, freighters, and other vessels
  • LNG/LPG processing & storage facilities
  • Oil & gas refineries
  • Petrochemical plants
  • Gas & electric utilities
Additional Features
  • Non-intrusive operator interface is easily achieved by contacting a magnetic wand with the glass housing cover and accessing the intuitive, menu-driven programming screen
  • Tri-color status LED indicates operational mode, fault & gas presence
  • Two - Analog 4-20mA Relay Outputs
  • Four - Direct Relay Outputs are standard

Specifications
Electrical Characteristics
Voltage+24VDC Nominal (+18 to 32VDC)
Power4.3 W, standby 5.3 W, during alarm
12.0 W with heater on (temp ≤ 30°C)
OutputsAnalog signal: 2x +4-20mA
Digital RS-485 Modbus RTU
HART communication port
Three User Programmed Alarm Relays
One Fault Condition Programmed Relay
Technical Specifications
Humidity0 to 100% relative humidity, non condensing
Operating Temperature-58°F to +167°F (-50°C to +75°C)
-76°F to +167°F (-50°C to +75°C), with heater enabled
Storage temperature-76°F to +185°F (-60°C to +85°C)
Ingress ProtectionIP67
SIL RatingSIL 2, FM/CSA Class I Division 1 certification
Mechanical Characteristics
Material316 Stainless Steel
Conduit Connection5 Conduit Entrances , 3/4” NPT
Dimensions7.50” x 5.60” x 4.28”
Weight12.8 lbs (5.8 kg)
Warranty5 years
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    3 Items found.
100-0015-CL2
(5815)

ESP SAFETY  100-0015-CL2

ESP Safety Sensor Assembly, PGU-Clorine (CL2); Plug-in sensor & stainless steel housing. Includes weather protective dust cap.



$690.00 
100-0008-SS
(4725)

ESP SAFETY  100-0008-SS

ESP Safety Vector 2-channel gas detector controller . Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. It can be configured with one or two optional sensors, including: Chlorine (Cl2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Hydrogen (H2), Hydrogen Sulfide (H2S), Methane (CH4), Ammonia (NH3), Oxygen (O2), Propane (C3H8) and Sulfur Dioxide (SO2).

Configure

$922.50 
100-0009-01-A
(4724)

ESP SAFETY  100-0009-01-A

ESP Safety UPES 16-channel (4-20mA) gas and flame detector controller, or 128 Modbus digital RS-485 channels (16 ports 8 channels each) for ESP Devices. Includes Modbus RS-485 output port (both analog and digital versions), power supply and 3 alarm relays and audible alert. 3Ux19" modular size, FM & ABS Class I Division 1, Ex CE and IECEx Approved.

Configure

$1,732.50 
> CHLORINE :    22 Items found.
M001-0004-000
(5995)

MPOWER  M001-0004-000

mPower UNI MP100 Portable Single Gas Detector for detection of Chlorine (Cl2) 0-50ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$278.40 
BWS1-C-Y
(6384)

BW  BWS1-C-Y

BW Solo Serviceable Single-gas Detector for Chlorine (Cl2) 0-50 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

364-455-01-365-782-11
(6151)

DELPHIAN  364-455-01-365-782-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Chlorine (Cl2) 0-10 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PC3-6924
(6810)

PROSENSE  PC3-6924

Prosense PC3-6924 Gas Detector with Electrochemical sensor for Chlorine (Cl2) with range 0-10 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$823.68 
P-6934
(6785)

PROSENSE  P-6934

Prosense P-6934 Gas Detector with Electrochemical sensor for Chlorine (Cl2) with range 0-10ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$900.90 
SPSTAXL1
(1482)

HONEYWELL  SPSTAXL1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Chlorine (Cl2) 0-5ppm complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-5 ppm, 0-15 ppm)

Configure

$929.07 
PQN-6934-1/2
(6958)

PROSENSE  PQN-6934-1/2

Prosense PQN-6934 Gas Detector with Electrochemical sensor for Chlorine (Cl2) with range 0-10ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
GG-CL2-B-5
(2962)

CALIBRATION TECHNOLOGIES  GG-CL2-B-5

CTI GasGuard Cl2 Chlorine Electrochemical Sensor (0-5 ppm) for gas leak detection in process areas, tank storage, sanitizing systems and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,122.00 
PQD-6934-1/2
(6746)

PROSENSE  PQD-6934-1/2

Prosense PQD-6934 Gas Detector with Electrochemical sensor for Chlorine (Cl2) with range 0-10ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,235.52 
GG-CL2-5-EXP
(5977)

CALIBRATION TECHNOLOGIES  GG-CL2-5-EXP

CTI GG-CL2-EXP Explosion Proof Electrochemical Gas Sensor for Chlorine (Cl2) 0-5 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,383.00 
2106B1410
(1456)

HONEYWELL  2106B1410

Honeywell Sieger Sensepoint Gas Detector Transmitter for Chlorine (Cl2) (0-5 ppm to 0-15 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,402.14 
1100ALD-109014/01P-L0
(6910)

RC SYSTEMS  1100ALD-109014/01P-L0

RC Systems SenSmart 1100 gas detector for Chlorine (Cl) 0-1ppm to 0-50ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,528.57 
S3KUL2-XNXXSL1SS
(687)

HONEYWELL  S3KUL2-XNXXSL1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring CHLORINE (Cl2) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-5.0ppm, user adjustable (5.0 to 20.0ppm, 5.0ppm increments) Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,640.19 
41001AL-0-1012/0005P/L0
(7160)

RC SYSTEMS  41001AL-0-1012/0005P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Chlorine (Cl2) 0-5 to 0-5000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,753.24 
51001AL-0-1012/0005P/L0
(7125)

RC SYSTEMS  51001AL-0-1012/0005P/L0

RC Systems SenSmart 5100 3-wire gas detector for Chlorine (Cl2) 0-5 to 0-5000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,809.09 
961-740026-010G
(6353)

DETCON  961-740026-010G

Detcon DM-100-CL2 Electrochemical Chlorine (Cl2) 0-10ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

SPXCDULNL2
(1898)

HONEYWELL  SPXCDULNL2

Honeywell Sensepoint XCD RTD Gas Detector for Chlorine (Cl2) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 5 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,920.63 
967-747490-010
(6075)

DETCON  967-747490-010

Detcon DM-700-CL2 Electrochemical Smart Chlorine (CL2) 0-10 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

2100AL-0-9014/01P/L0
(118)

RC SYSTEMS  2100AL-0-9014/01P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Chlorine (Cl) 0-1ppm to 0-50ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$2,003.89 
XNXUTAENNNNN-XNXXSL1SS
(837)

HONEYWELL  XNXUTAENNNNN-XNXXSL1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Chlorine (Cl2) 0-5.0ppm, user adjustable (5.0 to 20.0ppm, 5.0ppm increments) compatible with all Honeywell gas sensing technologies, with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,119.28 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.