GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head configured for Smart IR combustible 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit) and Hydrogen Sulfide (H2S), QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D. Also available for Methane 0-100% Vol, Propane, Propylene, Butane, Pentane, Hexane, Ethylene, Ethane, Ethylen Oxide (EtO), Methyl Bromide, Butane, Isopropanol, Methanol, Toluene, Acetone, MEK and Xylene. Second channel with local stainless steel sensor head configured for Hydrogen Sulfide (H2S) with range 0-25 to 0-5000 ppm (included).

Inquiry

Features

  • CSA Certified for Class I, Div 1 explosion-proof installations
  • Monitor any combination of toxic and combustible gases
  • High resolution color TFT display for easy recognition of alarm status
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibra- tion with programmable cal value
  • Dual independent 4-20mA analog outputs with 0-4mA pass-through
  • Standard Ethernet port with built- in web server for remote access
  • Power-up and post-calibration delays eliminate false alarms
  • Backlit display for better visibility in low light conditions
  • Optional 4x SPDT alarm relays and dual MODBUS serial ports
  • Graphic display shows values, units, trend graph, alarm levels
  • Security settings allow user to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand
  • Manufactured in USA

The new GASMAX CX gas monitor from GDS Corp delivers quality, performance and advanced features for the most critical gas detection applications. Designed especially for situations where gas readings need to be transmitted in real time via a variety of communication options, the GASMAX CX includes dual 4-20mA outputs and built-in Ethernet port with MODBUS/TCP and web server. An optional output board incldues 4X alarm relays and dual serial MODBUS channels with data rates up to 115k bits per second.

Widest Variety of Available Sensors

Built-in dual channel electronics allow the GASMAX CX to support almost any combination of GDS Corp toxic, bridge or 4-20mA sensors. Channel 1 features a dedicated bridge input configuration for traditional direct catalytic bead sensors, and both channels support the new 10- 98xx digital output low-noise sensors. Built-in sensor monitoring circuitry detects sensor faults or warns of missing sensors.

Advanced User Interface

The highly visible full color TFT backlit display makes the GASMAX CX gas monitor extremely easy to read and operate, and magnetic switches arranged around the screen allow users to perform calibrations or change settings without opening the enclosure. Bright flashing yellow or red alarm screens give users the ability to instantly recognize alarm conditions and take appropriate action.

Reliable, Dependable, Certified

The GASMAX CX carries a full two-year warranty and is fully CSA certified for use in Class I Division 1 hazardous areas.

Power Input 10-30VDC at < 10 watts with relay board (all relays energized)
DisplayQVGA color TFT display with value, 30-minute trend and bargraph
Channel One InputDigital sensor, bridge-style direct sensor or 4-20mA analog input
Channel Two InputDigital sensor or 4-20mA analog input
Standard OutputDual 3-wire 4-20mA current source. Max loop R is 600 ohms @ 24VDC
Ethernet RJ-45 with built-in web page for remote acces
Optional OutputThree programmable relays plus dedicated FAULT relay
Dual programmable master / slave MODBUS RS-485 serial interfaces
EnvironmentalOperating range -40°C to +60°C
Sensors include sensor heater for low temperature operation
Relative humidity to 95% non-condensing with GDS-IR; to 85% non- condensing when using electrochemical sensors
HousingAluminum housing with epoxy paint standard; Optional #316 stainless steel housing (specify [SS] in part number)
DimensionsWidth 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals CSA Certified for Class I, Div 1, Grps B, C, D.
Warranty 2 years on electronics and one year on sensors

Gases

GAS TYPE SENSOR RANGE COMMENTS
Methane 0 – 5% volume Fully characterised for methane.
Methane 0 – 100% volume Fully characterised for methane
Propane 0 – 2% volume Fully characterised for propane.
Cross-reference factors available for: Butane, Pentane,
Hexane, Ethanol, Ethylene, Propylene, Ethane, Cyclopentane,
Isopropanol, Methanol, Toluene, Acetone, Methyl ethyl ketone
(MEK) and Xylene , see Note 1
Propane 0 – 100% volume Fully characterised for propane
Propylene 0 – 100% volume Fully characterised for propylene
Butane 0 – 2% volume Fully characterised for butane
Pentane 0 – 2% volume Fully characterised for pentane
Hexane 0 – 1% volume Sensor output linearised for hexane, see Note 1
Ethylene 0 – 3% volume Sensor output linearised for ethylene, see Note 1
Ethane 0 – 3% volume Fully characterised for ethane
Ethylen Oxide 0 – 3% volume Fully characterised for ethylene oxide
Ethanol 0 – 5% volume Sensor output linearised for ethanol, see Note 1
Methyl Bromide 0 – 25,000 ppm Sensor output linearised for methyl bromide, see Note 1
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000
> ACCESSORIES - RELATED - CONSUMABLES :    13 Items found.
10-0203
(259)

GDS  10-0203

GDS Sensor calibration cup for stainless steel / aluminum sensor heads



 
1200-0267
(3192)

GDS  1200-0267

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder.

1200-0768
(3191)

GDS  1200-0768

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 25% LEL. Balance Air. 103L Aluminium Cylinder.

10-9857-R02
(3413)

GDS  10-9857-R02

Infrared Smart IR Sensor configured for Ethylene Oxide ETO with range 0-3% volume. For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
10-9870-R06
(3379)

GDS  10-9870-R06

Catalytic Smart LEL sensor configured for Methane with range combustible 0-100% LEL (Lower Explosive Limit). For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
10-9815-R04
(3355)

GDS  10-9815-R04

Electrochemical Smart Sensor configured for Hydrogen Sulfide (H2S) with range 0-25/0-5000 ppm. For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.

1200-0587
(3124)

GDS  1200-0587

GDS Gas Detector Calibration Gas Kit Methane (CH4) 25% LEL. Balance Air. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0522
(3125)

GDS  1200-0522

GDS Gas Detector Calibration Gas Kit Methane (CH4) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

10-9852-R06
(3412)

GDS  10-9852-R06

Infrared Smart IR LEL Sensor configured for Methane by Volume. For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
10-9853-R02
(3381)

GDS  10-9853-R02

Infrared Smart IR Sensor configured for Carbon Dioxide CO2 with range 0-5% volume. For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
10-9851-R06
(3374)

GDS  10-9851-R06

Infrared Smart IR LEL Sensor with range 0-100% LEL (Lower Explosive Limit) for combustibles (specify). For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
10-9850-R06
(3373)

GDS  10-9850-R06

Infrared Smart IR LEL Sensor configured for Methane with range combustible 0-100% LEL (Lower Explosive Limit). For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.