Honeywell Xnxutavnnif1 | Lel Infrared | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   XNXUTAVNNIF1

SKU# (1225)



HONEYWELL XNXUTAVNNIF1
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell XNX Universal Gas Detector Transmitter with MPD-AMIF1 IR Infrared sensor for %LEL Propane (C3H8) 0-100% LEL or Methane (CH4) 0-100% LEL and aluminum housing. The XNX is compatible with all Honeywell gas sensing technologies. 3-wire 4-20 mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL2. Optional Alarm Relays, Modbus, Fieldbus. *** Detector will be provided as two separate items: XNX transmitter & MPD sensor head, to be assembled by the end user ***

DISPLAY   4-20 mA   RELAYS   UL   ATEX   DIV 1   ZONE 1   SIL2   HART   MODBUS

XNXUTAVNNIF1   
2,390.83

Agency Approval & Entry Threads
Enclosure
Interface option
Local HART Port
Sensor and Range
Custom Tag

   13 Weeks  ]
144 Variants of base SKU / 30 Shown below

The XNX Universal Transmitter marks a new turn in gas detection from Honeywell Analytics. It supports the widest range of sensors on a common platform and offers a modular choice of inputs and outputs.

FEATURES

High performance
  • Flammable gas detection 0 to 100% LFL/LEL
  • Point IR with heated optics provides immunity to poisoning and no hidden faults
  • Open-path IR flammable gas detection in LEL-m measurement
  • Electrochemical cell offers toxic gas detection in ppm
  • IR cell provides CO2 and combustible gas monitoring
  • Robust and reliable operation in explosive areas and harsh environments
Flexible Operation
  • 3 versions - supports mV (Catalytic Bead and IR Cell), Electrochemical Cell and IR (point and open-path) gas detection
  • Multi-Purpose Detector (MPD) with field serviceable mV, Catalytic bead and IR Cell capability
  • 4-20mA with HARTŪ as standard
  • Multiple communications options include up to 3 relays, MODBUSŪ and FOUNDATIONŪ H1 Fieldbus (pending)
  • Optional local IS port for handheld HART configurator
Easy to Use
  • Large, backlit, easy-to-view LCD display offers multisensory indicators (visual icons, colored buttons, text, etc.) to display gas and sensor readings
  • User interface supported by 8 selectable languages (English, Spanish, German, Italian, Portuguese, French, Russian, Chinese)
  • Self-test and fault indication features
  • Non-intrusive, one-man operation
  • Quick calibration with auto-inhibit
Easy to Install
  • 3 or 4 wire operation, source, sink or isolated
  • Use with conduit or cable installations
  • Simple plug-in sensors and replaceable cells
  • NEMA 4X IP66 rated for rugged indoor/outdoor use
Cost Effective
  • Minimal training required
  • One-man operation
  • Plug-in sensor replacement
  • All necessary accessories included
Applications
  • Offshore Oil & Gas production platforms
  • Onshore Oil terminals
  • Refineries
  • Gas Transmission
  • Gas Distribution
  • LNG terminals
  • Gas storage terminals
  • Chemical plants
  • Petrochemical plants
  • Solvent recovery operations

XNX is designed for flexible integration, simple installation, user friendly operation and straightforward maintenance. It is ideal for use with a range of gas monitoring controllers or industry standard PLCs. Users are assured of being protected in all conditions with Honeywell Analytics gas monitoring solutions.

Bringing together the best solutions in gas detection

Infrared (Open Path IR, Point IR, IR Cell)
  • Supports Honeywell Analytics Searchline Excel, Searchpoint Optima Plus
  • Failsafe operation
  • Fast speed of response
  • Reduced routine maintenance
  • Immune to catalytic poisons
  • Long operating life
  • Works in inert atmospheres
Optima Point IR Sensors

XNX's modular design enables Honeywell Analytics to offer appropriate, cost effective solutions to a wide range of gas detection requirements.

With the XNX, you are freed from the need to add extra controllers, junction boxes, relays, monitors and other equipment accessories.

The XNX Universal Transmitter is an excellent choice for those who want a total integrated monitoring and safety solution for an industrial plant.

The XNX's powerful advanced communications module adds increased functionality and flexibility to a gas detection network. Standard HART communications, along with optional Modbus, Foundation Fieldbus (pending) or relays, interface with a PLC and a host of other protocol compatible devices found in industrial applications.

XNX Output Options

Back-lit, easy-to-read LCD display with icons includes a broad range of language options including English, Spanish, French, Italian, Portuguese, German, Russian and Chinese to meet global requirements.

Ordering Information

The XNX part numbering system contains all necessary information to convey the product configuration including options. Agency, Port Thread, Enclosure Material, Sensor Personality define the standard unit. Three option fields are used to define optional Relay or Fieldbus interfaces and factory installed local HARTŪ. To order XNX parts, call 800-538-0363.

XNX Order Information Matrix

Advanced infrared point gas detector

FEATURES

Why Searchpoint Optima Plus is the right choice...
  • The proven strengths of the original Searchpoint OPTIMA design
  • Experience gained from over 30,000 units installed worldwide
  • The latest technology and techniques used to develop the successful Sieger open path gas detector, the Searchline Excel
  • Improved reliability
Why Infrared?
  • Failsafe operation
  • Fast speed of response
  • Reduced routine maintenance
  • Immune to catalytic poisons
  • Long operating life
  • Works in inert atmospheres
Why Searchpoint Optima?
  • Can detect a wide range of hydrocarbon gases including solvents
  • Increased reliability with no moving parts
  • Increased stability from self compensating optics
  • Immune to long term component drift
  • Remote functional gas test facility
  • Certified for North American and European Hazardous areas
Why Searchpoint Optima Plus?
  • Increased false alarm rejection with ✔2 SOFTWARE™
  • Increased uptime with contaminated optics warning
  • Dynamic Heating Control ensures condensation free optics
  • No undetected failures
  • Improved diagnostics
  • Integral event logging
  • Reduced power consumption
  • Certified to many hazardous area classification schemes including: European (ATEX), UL, CSA and more
Optics Block

The 4-channel (dual compensated) optics-block is the heart of the Searchpoint OPTIMA PLUS. It is specifically designed to compensate for changes in the external environment similar to 2- channel designs, but also compensates for long term component drift such as infrared sources and detectors. This combined with the de-focussed beam provides the Searchpoint OPTIMA PLUS with the most stable optics design possible.

XNX Transmitter
Material LM25 Aluminum, painted (SS316 painted optional)
Cable Entries 5 conduits/cable entries – (2 right, 2 left, 1 bottom) Available in ū" NPT, or M25
Termination Cage Clamp pluggable Terminal Blocks with retaining screws, 0.5 to 2.5mm (12-28 AWG)
Mounting XNX Enclosure Bracket (ears on casting for u-bolt). Integral cast mounting flanges provide secure mounting to surfaces, channels or up to 6" Pipe.
Optional Remote sensor (up to 50 ft / 15.2 M) for Cat Bead and Toxic
User interface Standard Custom Backlit LCD. 2.5" High Resolution DOT Matrix Display. Discrete Alarm and Status indication. Reliable Non-Intrusive 4 button interface magnetic wand access. Optional HART Handheld with IS Port
Signal Standard HART over 3-wire 4-20mA (sink or source). Optional Modbus over RS-485 and Foundation Fieldbus
Environmental
Temperature -40°C to +65°C / -40°F to +149°F (sensor dependent)
Humidity 20 to 90% RH non-condensing
IP Rating NEMA 4X IP65
Options
  Form C and SPDT 3 Relays, 240 VAC, 5A (2 Alarm, 1 Fault) (Mutually exclusive with Modbus and Fieldbus Options)
Power
  18V to 32V (24V nominal)
Hazardous Area Approvals
 
Performance Approvals UL Certified Class 1, Div 1
ATEX Zone 1
Display Module & User Interface (Standard)
Display Type Backlit LCD
Information Displayed
Base Information: Gas Reading
Gas Name and Units of measurement
Fault and Alarm Status
Large Numeric concentration or LEL display
Bar graph showing current reading, set points and full scale.
Fault/Alarm and Operating Status Indication: Security settings allow multi level operator access for set-up, configuration and calibration
Event history stores Time and Date of all Alarm, Diagnostic, Configuration events
Interface Magnetic wand with terminal screwdriver (supplied each unit)
4-20mA & HART (Standard Supply)
Description Fully configurable isolated 4-20mA & HART output module providing current sink, current source and isolated modes of operation. (supports HART 6.0 protocol)
Non-intrusive Interface Optional local IS port to enable HOT connection of a HART handheld configurator
Operating Modes Current sink / Current source / Isolated current sink /Conventional or with HART data
Output Range 0 to 22mA
4-20mA Signal Accuracy +/- 1% FS
Max loop resistance 600 Ohms at 24Vdc loop supply
Functions Supported via HART
Gas Reading Detailed Sensor Information Including: RTC (Excel Only)
Gas Name and Units of measurement 4-20mA signal level Optical Signal Level Calibration and Configuration status
General/Device Information Dynamic Reserve (Excel Only) Detailed Fault and Warning Information
Installation Raw reading Fault and Alarm History
Configuration Temperature
Forcing of 4-20mA output
Local IS HART Port (Optional)
Description Provides externally accessible IS connections to the XNX transmitter to enable HOT connection of HC275/375 HART or equivalent hand held configurator.
Installation Fitted to one of the cable entries on the XNX transmitter.
Environmental Protection Terminals protected by cover to IP 66 when not in use
Relay Module (Optional)
Description Provides three fully user configurable relay outputs that can be switched based on the current gas level and/or status of the transmitter. Provides 2 x SPCO alarm and 1 x SPCO fault relays. Single Pole Double Throw SPDT. Option PCB Factory installed in display module.
Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
Rating
Maximum: 240VAC, 5A (non inductive load) Minimum: 5V, 10mA (non inductive load)
Electrical Connections Fault: Common, Normally Open, Normally Closed
Alarm 1: Common, Normally Open, Normally Closed
Alarm 2: Common, Normally Open, Normally Closed
Configuration
Default Configurable Options
Fault Relay: Fault Relay:
Normally energized Normally energized / normally de-energized
Non latching None
Signal inhibit as fault Enable/disable
Alarm 1 / 2 Relays: A1 / A2 Relays:
Normally de-energized Normally energized / de-energized
Non latching Latching / non latching
Alarm rising on gas reading Alarm on rising / falling
Alarm level 20% and 40% of scale Alarm level 10% to 90% of full scale
Hysteresis of 2% of scale
Re-setting of Latched Relays Easily accessible interface on display (if used) or via HART interface (local or remote)
Note Use of the Relay Module or 'Other' Communications Module (E.g. Foundation Fieldbus) is mutually exclusive. However, relay function may be used in conjunction with standard communication output i.e. 4-20mA with HART.
Relay Specific Functions via HART Interface Relay status information / Reset of latched conditions / Configuration of relays Forcing of relay state
Reset through non intrusive User Interface. Remote Switch closure using Remote Reset input Remotely through HART
Foundation Fieldbus Module (Optional)
Description Foundation Fieldbus compliant digital communications interface enables connection of the XNX transmitter to a multi-drop Foundation Fieldbus H1 network.
Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
Connections Sig+, Sig- and Screen
Physical Layer Conforms to IEC 1158-2 and ISA 50.02, 31.25Kbits/s
Maximum No. of Nodes 32
Functions Supported
Gas Reading Detailed Sensor Information Including: Detailed Fault and Warning Information:
Gas Name and Units of measurement Optical Signal Level Fault and Alarm History
Instrument status (OK, warning, fault, over-range) Dynamic Reserve (Excel Only) Zero Calibration
Remote zero and span calibration (detector dependent) 24V supply voltage
Remote zero and span calibration (detector dependent) Temperature
  RTC (Excel Only)
  Calibration and Configuration status
Modbus RTU Module (Optional)
Description The Modbus output module provides an Isolated RS485 output to enable the connection of the XNX transmitter to a multi-drop Modbus network
Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
Connections RS485+, RS485-, Drain
Physical Layer Isolated RS485, 1200 to 19.2K Baud
Maximum No. of Nodes 254 XNX compatible transmitters only
Protocol Modbus RTU
Functions Supported As per Foundation Fieldbus Module (Optional) - see above
Searchpoint Optima Plus Specification
Output
Measuring range 4-20 mA sink or source, (Default current source)
Inhibit 1-3 mA (Default 2 mA)
Warning 0-4 mA (Default 4 mA)
Fault 0 mA
Over range 20-21.5 mA (Default 21 mA)
Digital Output Optional Multidrop Modbus RS485 (via DVC/DX100(m))
Material 316 stainless steel
Weight 1.6 kg
Accuracy
Optima PLUS (HC) Baseline < ą1% LEL, 50% FSD <ą2% LEL
Optima PLUS (ET) Baseline < ą2% LEL, 50% FSD <ą3% LEL
Repeatability < ą2% LEL at LEL 50% FSD
Linearity < 5% FSD
Response time T50 < 4.5 seconds, T90 < 6.5 seconds (for methane, including weather protection)
Operational and certified -40°C to +65°C temperature range
Drift with time and over temperature range -40°C to +65°C
Baseline < ą2% LEL
50% FSD < ą4% LEL
Variation with pressure 0.1% (of reading) per mbar
Power supply 18-32 V (24 V nom) DC, < 4.5 W max
Environmental protection IP 66/67
Diagnostics (and re-calibration) Via certified Hand Held Interrogator
Safety approvals

ATEX,
II 2 G EEx d IIC
   T5 (Tamb -40°C to +55°C)
   T4 (Tamb -40°C to +65°C)
UL/CSA Class 1, Div 1, groups B, C, and D (-40°C to +65°C)
GOST and SAA

Performance approvals EN50054, EN50057, CSA C22.2 152.
EMC compliance EN 50270
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    10 Items found.
0060-1051
(1883)

HONEYWELL  0060-1051

Ferrite bead for XNX transmitters with mV sensors



$18.14 
1226A0411
(834)

HONEYWELL  1226A0411

Calibration Gas Flow Adaptor (cup) for use with XNX MPD Catalytic Bead and IR/CO2 sensors.



$111.97 
02000-A-1635
(1881)

HONEYWELL  02000-A-1635

Honeywell Weatherproof cap for use with Toxic/Oxygen detector including remote gassing nozzle (for Toxic Sensepoint Zareba and Sieger, Signalpoint, Satellite -with adapter-, XNX MPD, Series 2000 and 705 sensors)



$115.08 
90095187
(6713)

PORTAGAS  90095187

Calibration Gas Propane (C3H8) 50% LEL 1.1% Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$135.15 
90090227
(1313)

PORTAGAS  90090227

Calibration Gas Methane (CH4) 50% LEL 2.5% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$135.15 
10624200
(1305)

PORTAGAS  10624200

Calibration Gas Propane (C3H8) 50% LEL 1.06% Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$135.15 
02000-A-1640
(1471)

HONEYWELL  02000-A-1640

Honeywell Nylon Weather Protection for Combustible/MPD, Sieger, Zareba Sensepoint, XCD RTD, RFD, 705, XNX Combustible Sensors with test/calibration gas port.



$138.93 
1226A0354
(2136)

HONEYWELL  1226A0354

Remote Gassing Kit for XNX transmitters, includes 50' Teflon tubing, mounting bracket, tube cap and device adapters in 1/4" and 1/8" ID to attach to bump test ports on the weatherproof cap of your gas detector sensor head.



$258.16 
2441-0022
(1969)

HONEYWELL  2441-0022

Honeywell UL/CSA Aluminum 6 wire Junction Box 3/4" NPT entries, can be used for remote sensors with 3/4" NPT male threads, can be used with MPD sensors.



$376.36 
TPPLBDWA2NNNNNN
(5825)

HONEYWELL  TPPLBDWA2NNNNNN

Honeywell Touchpoint Plus Wall-mounted Alarm Controller for up to 8 gas detection channels (16 w/ expansion unit). Dustproof and waterproof. Polycarbonate ABS Housing (NEMA 4X). Includes touchscreen interface, built-in sounder, 3 alarm relay outputs, datalogging to SD card and remote reset and inhibit inputs. AC or DC supply voltage. Up to 24 relay outputs and 8mA outputs. IP65. UL and CSA approvals (Class I Div 2).

Configure

$2,436.75 
> LEL INFRARED :    34 Items found.
012731-504
(7260)

DET-TRONICS  012731-504

Det-tronics FlexSight LS2000 Infrared gas detection system for combustible hydrocarbon gases 0-5% LEL. 4-20 mA output, HART and RS-485 Modbus communication. 24 VDC. Stainless steel transmitter and receiver. IP66/IP67. NEMA Type 4X. Suitable for Class I, Div 1 and Div 2; Class II, Div 1; Class I, Zone 1; and Zone 1, Zone 2. FM, IEC and SIL 2 Approvals.



 
006300-012
(7250)

DET-TRONICS  006300-012

Det-tronics PIR9400 PointWatch Infrared Hydrocarbon Gas Detector for Methane 0-100% LEL. Diffusion based. 18-30 VDC. 4-20 mA output signal. Explosion proof. IP66. Suitable for Class I Div 1, Div 2, Zone 1 and Zone 2 hazardous areas.



 
116-014048-232
(7230)

AUTRONICA  116-014048-232

Autronica AutroPoint HC200 Infrared IR Hydrocarbon Gas Detector calibrated to methane, propane, ethylene, or butane 0 to 100% LEL. Explosion-proof stainless steel housing. 4-20 mA signal with HART communication. MODBUS and ASCII supported. SIL2, FM/CSA, DEMKO, IECEx and ATEX certified for use in Class I, Div 1 and Div 2, and Zone 1 and Zone 2.



 
SV-3003
(7374)

PROSENSE  SV-3003

Prosense SafeVader SV-3003 Fixed Gas Detector with Infrared sensor for Hydrocarbons (Methane, Propane, Butane, LPG, Pentane, Gasoline/Petrol Vapor, Propylene and other combustibles) with range 0-100% LEL. 4-20 mA Analog, Modbus RS485 RTU and relay outputs (Alarm1, Alarm2, Fault). 12 to 28VDC. ABS Plastic enclosure. IP54.

Configure

$629.01 
P-3033
(6722)

PROSENSE  P-3033

Prosense P-XY35 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$833.84 
PXN-3033-1/2
(7317)

PROSENSE  PXN-3033-1/2

Prosense PXN-XY33 Gas Detector with Infrared sensor for Hydrocarbons (LPG, Methane, Petrol/Gasoline Vapor, Butane, Propane, Pentane, Propylene and other explosive Hidrocarbons) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Relay and HART card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKEX or INMETRO approval. IP65, Optional IP66 Adaptor.

Configure

$977.30 
PXN-7133-1/2
(7342)

PROSENSE  PXN-7133-1/2

Prosense PXN-7133 Gas Detector with Infrared sensor for Carbon Dioxide with range 0-5000ppm to 0-60% vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Relay and HART card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKEX or INMETRO approval. IP65, Optional IP66 Adaptor.

Configure

$1,004.20 
PQN-3033-1/2
(6946)

PROSENSE  PQN-3033-1/2

Prosense PQN-XY33 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Marine Bureau Veritas Certification, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,075.93 
PXD-3033-1/2
(7316)

PROSENSE  PXD-3033-1/2

Prosense PXD-XY33 Gas Detector with Infrared sensor for Hydrocarbons (LPG, Methane, Petrol/Gasoline Vapor, Butane, Propane, Pentane, Propylene and other explosive Hidrocarbons) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Optional Relay and HART card. LCD Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKEX or INMETRO approval. IP65, Optional IP66 Adaptor.

Configure

$1,129.73 
PQD-3033-1/2
(6719)

PROSENSE  PQD-3033-1/2

Prosense PQD-XY33 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs, Marine Bureau Veritas Certification, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$1,246.28 
1300ALD-109050/100P-L0
(6904)

RC SYSTEMS  1300ALD-109050/100P-L0

RC Systems SenSmart 1300 Infrared (IR) Gas Detector for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide 0-100% LEL or %Vol with 'ST-48' smart transmitter. Infrared (IR) sensor. 3-Wire bridge. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class I Div 1 (Explosion Proof).

Configure

$1,467.53 
SPXCDULNRX
(659)

HONEYWELL  SPXCDULNRX

Honeywell XCD Sensepoint Gas Detector, Methane (Natural Gas) (CH4) Infrared Sensor combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66. 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20 mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Div 1 or ATEX (Zone 1) IECEx available.

Configure

$1,478.48 
100-0001-M11-SS-1-2-CH4
(4722)

ESP SAFETY  100-0001-M11-SS-1-2-CH4

ESP Safety SGOES Infrared Gas Detector for measurement of hydrocarbon gases, Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Factory calibrated at 0%, 20%, 50%, and 95% LEL. Analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 3 relays. Includes protective weather cover and mounting hardware. IP66. SIL2 Rated. FM, ABS, IECEx, CE and CSA, Class I Div 1 Approved. Stainless steel construction. T90 response time= < 5 seconds (methane).

Configure

$1,490.40 
100-0008-00-SS-2-2/100-0015-IR-CH4
(4756)

ESP SAFETY  100-0008-00-SS-2-2/100-0015-IR-CH4

ESP Safety Vector 2-channel gas detector controller with smart Infrared IR Plug-In sensor included to detect Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Div 1 certification. Optional 2nd sensor available.

Configure

$1,593.90 
53001AL-0-9050/100P/L0
(7136)

RC SYSTEMS  53001AL-0-9050/100P/L0

RC Systems SenSmart 5300 3-wire gas detector with infrared (IR) sensor for Hydrocarbons 0-100% LEL or %Vol for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide with GEN2 smart sensor, Color backlit LCD Display and 4-20 mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Div 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays, HART.

Configure

$1,844.15 
SPXCDULNPX
(660)

HONEYWELL  SPXCDULNPX

Honeywell XCD Sensepoint Gas Detector, Infrared Sensor for Propane (C3H8), Ethylene (C2H4), Butane (C4H10) & Pentane (C5H12) combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20 mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Div 1 or ATEX (Zone 1) IECEx available.

Configure

$1,895.79 
2108N4000N
(3414)

HONEYWELL  2108N4000N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20 mA source, optional HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, ATEX/IECEx approved (Also available UL/INMETRO and CSA). Optional remote gassing cell.

Configure

$2,197.84 
2108N4100N
(1676)

HONEYWELL  2108N4100N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20 mA source, optional HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, UL/INMETRO approved (Also available ATEX and CSA). Optional remote gassing cell.

Configure

$2,197.84 
967-215520-100A
(2133)

DETCON  967-215520-100A

Detcon IR-700-CH Infrared Smart Combustible Sensor Assembly. Designed to detect hydrocarbon gases 0-100% LEL. 4-20 mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water-Proof, Corrosion-Proof and Vibration-Proof. Optional aluminum or stainless steel junction box. Gases: Methane, Ethane, Propane, Butane, Pentane, Hexane, Ethylene, Gasoline Vapor, Diesel Fuel Vapor, Jet Fuel Vapor Optional Alarm Relays, HART.

GM/BX-1-R0100/0
(7293)

GDS  GM/BX-1-R0100/0

GDS GASMAX BX Gas Detector for Hydrobarbons 0-100% LEL, GDS-IR Sensor, 3-wire. Includes 4-20mA analog output and optional 3X isolated 5A alarm relays and MODBUS interface. TFT backlit display. CSA Class I Div 1. Wide selection of hydrocarbons, alcohol, fuel and combustibles: Propane, Isobutane, Pentane, Butane, Ethanol, Methanol, Propylene, Ethylene, Exane, Jet-A, Diesel, Gasoline, Isopropyl Alchohol and others.

Configure

$2,215.00 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.